Definitions of Managed Objects
for the Internet Small Computer System Interface (iSCSI)
Abstract
This document defines a portion of the Management Information Base
(MIB) for use with network management protocols. In particular, it
defines objects for managing a client using the Internet Small
Computer System Interface (iSCSI) protocol (SCSI over TCP).
This document obsoletes RFC 4544.
Status of This Memo
This is an Internet Standards Track document.
This document is a product of the Internet Engineering Task Force
(IETF). It represents the consensus of the IETF community. It has
received public review and has been approved for publication by
the Internet Engineering Steering Group (IESG). Further
information on Internet Standards is available in Section 2 of
RFC 5741.
Information about the current status of this document, any
errata, and how to provide feedback on it may be obtained at
http://www.rfc-editor.org/info/rfc7147.
Bakke & Venkatesen Standards Track [Page 1]
RFC 7147 iSCSI MIB April 2014
Copyright Notice
Copyright (c) 2014 IETF Trust and the persons identified as the
document authors. All rights reserved.
This document is subject to BCP 78 and the IETF Trust's Legal
Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info) in effect on the date of
publication of this document. Please review these documents
carefully, as they describe your rights and restrictions with respect
to this document. Code Components extracted from this document must
include Simplified BSD License text as described in Section 4.e of
the Trust Legal Provisions and are provided without warranty as
described in the Simplified BSD License.
This document may contain material from IETF Documents or IETF
Contributions published or made publicly available before November
10, 2008. The person(s) controlling the copyright in some of this
material may not have granted the IETF Trust the right to allow
modifications of such material outside the IETF Standards Process.
Without obtaining an adequate license from the person(s) controlling
the copyright in such materials, this document may not be modified
outside the IETF Standards Process, and derivative works of it may
not be created outside the IETF Standards Process, except to format
it for publication as an RFC or to translate it into languages other
than English.
Bakke & Venkatesen Standards Track [Page 2]
RFC 7147 iSCSI MIB April 2014
Table of Contents
1. The Internet-Standard Management Framework ......................4
2. Introduction ....................................................4
3. Relationship to Other MIB Modules ...............................4
4. Relationship to SNMP Contexts ...................................5
5. Differences from RFC 4544 .......................................5
6. Discussion ......................................................6
6.1. iSCSI MIB Object Model .....................................7
6.2. iSCSI MIB Table Structure ..................................8
6.3. iscsiInstance ..............................................9
6.4. iscsiPortal ................................................9
6.5. iscsiTargetPortal .........................................10
6.6. iscsiInitiatorPortal ......................................11
6.7. iscsiNode .................................................12
6.8. iscsiTarget ...............................................12
6.9. iscsiTgtAuthorization .....................................12
6.10. iscsiInitiator ...........................................13
6.11. iscsiIntrAuthorization ...................................13
6.12. iscsiSession .............................................13
6.13. iscsiConnection ..........................................14
6.14. IP Addresses and TCP Port Numbers ........................14
6.15. Descriptors: Using OIDs in Place of Enumerated Types .....15
6.16. Notifications ............................................15
7. MIB Definition .................................................16
8. Security Considerations ........................................88
9. IANA Considerations ............................................89
10. References ....................................................89
10.1. Normative References .....................................89
10.2. Informative References ...................................91
11. Acknowledgments ...............................................91
Bakke & Venkatesen Standards Track [Page 3]
RFC 7147 iSCSI MIB April 2014
1. The Internet-Standard Management Framework
For a detailed overview of the documents that describe the current
Internet-Standard Management Framework, please refer to section 7 of
RFC 3410 [RFC3410].
Managed objects are accessed via a virtual information store, termed
the Management Information Base or MIB. MIB objects are generally
accessed through the Simple Network Management Protocol (SNMP).
Objects in the MIB are defined using the mechanisms defined in the
Structure of Management Information (SMI). This memo specifies a MIB
module that is compliant to the SMIv2, which is described in STD 58,
RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580
[RFC2580].
2. Introduction
This document defines a MIB module for iSCSI [RFC7143], used to
manage devices that implement the iSCSI protocol. It obsoletes RFC
4544 [RFC4544].
The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
"OPTIONAL" in this document are to be interpreted as described in
[RFC2119].
3. Relationship to Other MIB Modules
The iSCSI MIB module is normally layered between the SCSI MIB module
[RFC4455] and the TCP MIB module [RFC4022], and it makes use of the
IP Storage (IPS) Identity Authentication MIB module [RFC4545]. Here
is how these modules are related:
SCSI MIB Within systems where a SCSI layer is present, each
iscsiNode, whether it has an initiator role, target role,
or both, is related to one SCSI device within the SCSI
MIB module. In this case, the iscsiNodeTransportType
attribute points to the SCSI transport object within the
SCSI MIB module, which in turn contains an attribute that
points back to the iscsiNode. In this way, a management
station can navigate between the two MIB modules. In
systems where a SCSI layer is not present, such as within
an iSCSI proxy device, the iscsiNodeTransportType
attribute points to the appropriate corresponding object
within the appropriate MIB or is left blank.
Bakke & Venkatesen Standards Track [Page 4]
RFC 7147 iSCSI MIB April 2014
TCP MIB Each iSCSI connection is related to one transport-level
connection. Currently, iSCSI uses only TCP; the iSCSI
connection is related to a TCP connection using its
normal (protocol, source address, source port,
destination address, destination port) 5-tuple.
AUTH MIB Each iSCSI node that serves a target role can have a list
of authorized initiators. Each of the entries in this
list points to an identity within the IPS Identity
Authentication MIB module that will be allowed to access
the target. iSCSI nodes that serve in an initiator role
can also have a list of authorized targets. Each of the
entries in this list points to an identity within the
IPS-AUTH MIB module to which the initiator should attempt
to establish sessions. The IPS-AUTH MIB module includes
information used to identify initiators and targets by
their iSCSI name, IP address, and/or credentials.
This MIB module imports objects from RFCs 2578 [RFC2578], 2579
[RFC2579], 2580 [RFC2580], and 3411 [RFC3411]. It also imports
textual conventions from the INET-ADDRESS-MIB [RFC4001].
4. Relationship to SNMP Contexts
Each non-scalar object in the iSCSI MIB module is indexed first by an
iSCSI instance. Each instance is a collection of nodes, portals,
sessions, etc., that can define a physical or virtual partitioning of
an iSCSI-capable device. The use of an instance works well with
partitionable or hierarchical storage devices and fits in logically
with other management schemes. Instances do not replace SNMP
contexts; however, they do provide a very simple way to assign a
virtual or physical partition of a device to one or more SNMP
contexts, without having to do so for each individual node, portal,
and session row.
5. Differences from RFC 4544
[RFC7143] updates several RFCs, including [RFC3720]. This document
updates the iSCSI MIB correspondingly. The document uses
iSCSIProtocolLevel as defined in [RFC7144]. It obsoletes [RFC4544].
Below is a brief description of the changes.
- Added iscsiInstXNodeArchitecture to InstanceAttributes.
- Added iscsiSsnTaskReporting of type BITS to SessionAttributes.
- Added iscsiSsnProtocolLevel to SessionAttributes.
- Deprecated the marker objects.
- Fixed the errata to [RFC4544].
Bakke & Venkatesen Standards Track [Page 5]
RFC 7147 iSCSI MIB April 2014
- Added NOP counters at iSCSI session scope for heartbeat tracking.
- Added port number to the iscsiTgtLoginFailure and
iscsiIntrLoginFailure notifications, and to the last failure info
in iscsiInitiatorAttributesEntry.
- Added description string to the iSCSI portal.
- Added iscsiInstSsnTgtUnmappedErrors to support "Target Unmapped"
session failure reporting in the iscsiInstSessionFailure
notification.
- Added iscsiTgtLogoutCxnClosed and iscsiTgtLogoutCxnRemoved, which
maintain the count of Logout Command PDUs received by the target
with reason codes 1 and 2, respectively.
- Changed the conformance statements to match the above.
6. Discussion
This MIB module structure supplies configuration, fault, and
statistics information for iSCSI devices [RFC7143]. It is structured
around the well-known iSCSI objects, such as targets, initiators,
sessions, connections, and the like.
This MIB module may also be used to configure access to iSCSI
targets, by creating iSCSI portals and authorization list entries.
It is worthwhile to note that this is an iSCSI MIB module and as such
reflects only iSCSI objects. This module does not contain
information about the SCSI-layer attributes of a device. If a SCSI
layer is present, the SCSI MIB module [RFC4455] may be used to manage
SCSI information for a device.
The iSCSI MIB module consists of several "objects", each of which is
represented by one or more tables. This section contains a brief
description of the object hierarchy and a description of each object,
followed by a discussion of the actual table structure within the
objects.
Bakke & Venkatesen Standards Track [Page 6]
RFC 7147 iSCSI MIB April 2014
6.1. iSCSI MIB Object Model
The top-level object in this structure is the iSCSI instance, which
"contains" all of the other objects.
iscsiInstance
-- A distinct iSCSI entity within the managed system.
iscsiPortal
-- An IP address used by this instance.
iscsiTargetPortal
-- Contains portal information relevant when the portal
-- is used to listen for connections to its targets.
iscsiInitiatorPortal
-- Contains portal information relevant when the portal
-- is used to initiate connections to other targets.
iscsiNode
-- An iSCSI node can act as an initiator, a target, or both.
-- Contains generic (non-role-specific) information.
iscsiTarget
-- Target-specific iSCSI node information.
iscsiTgtAuth
-- A list of initiator identities that are allowed
-- access to this target.
iscsiInitiator
-- Initiator-specific iSCSI node information.
iscsiIntrAuth
-- A list of target identities to which this initiator
-- is configured to establish sessions.
iscsiSession
-- An active iSCSI session between an initiator and
-- target. The session's direction may be Inbound
-- (an outside initiator to the target represented by
-- this node) or Outbound (the initiator represented by
-- this node to an outside target).
iscsiConnection
-- An active TCP connection within an iSCSI session.
An iSCSI node can be an initiator, a target, or both. The iSCSI
node's portals may be used to initiate connections (initiator) or
listen for connections (target), depending on whether the iSCSI node
is acting as an initiator or target. The iSCSI MIB module assumes
that any target may be accessed via any portal that can take on a
target role, although other access controls not reflected in the
module might limit this.
Bakke & Venkatesen Standards Track [Page 7]
RFC 7147 iSCSI MIB April 2014
6.2. iSCSI MIB Table Structure
Each iSCSI object exports one or more tables: an attributes table,
and zero or more statistics tables, which augment the attributes
table. Since iSCSI is an evolving standard, it is much cleaner to
provide statistics and attributes as separate tables, allowing
attributes and statistics to be added independently. In a few cases,
there are multiple categories of statistics that will likely grow; in
this case, an object will contain multiple statistics tables.
iscsiObjects
iscsiDescriptors
iscsiInstance
iscsiInstanceAttributesTable
iscsiInstanceSsnErrorStatsTable
-- Counts abnormal session terminations
iscsiPortal
iscsiPortalAttributesTable
iscsiTargetPortal
iscsiTgtPortalAttributesTable
iscsiInitiatorPortal
iscsiIntrPortalAttributesTable
iscsiNode
iscsiNodeAttributesTable
iscsiTarget
iscsiTargetAttributesTable
iscsiTargetLoginStatsTable
-- Counts successful and unsuccessful logins
iscsiTargetLogoutStatsTable
-- Counts normal and abnormal logouts
iscsiTgtAuthorization
iscsiTgtAuthAttributesTable
iscsiInitiator
iscsiInitiatorAttributesTable
iscsiInitiatorLoginStatsTable
-- Counts successful and unsuccessful logins
iscsiInitiatorLogoutStatsTable
-- Counts normal and abnormal logouts
iscsiIntrAuthorization
iscsiIntrAuthAttributesTable
iscsiSession
iscsiSessionAttributesTable
iscsiSessionStatsTable
-- Performance-related counts (requests, responses, bytes)
iscsiSessionCxnErrorStatsTable
-- Counts digest errors, connection errors, etc.
iscsiConnection
iscsiConnectionAttributesTable
Bakke & Venkatesen Standards Track [Page 8]
RFC 7147 iSCSI MIB April 2014
Note that this module does not attempt to count everything that could
be counted; it is designed to include only those counters that would
be useful for identifying performance, security, and fault problems
from a management station.
6.3. iscsiInstance
The iscsiInstanceAttributesTable is the primary table of the iSCSI
MIB module. Every table entry in this module is "owned" by exactly
one iSCSI instance; all other table entries in the module include
this table's index as their primary index.
Most implementations will include just one iSCSI instance row in this
table. However, this table exists to allow for multiple virtual
instances. For example, many IP routing products now allow multiple
virtual routers. The iSCSI MIB module has the same premise; a large
system could be "partitioned" into multiple, distinct virtual
systems.
This also allows a single SNMP agent to proxy for multiple
subsystems, perhaps a set of stackable devices, each of which has one
or even more instances.
The instance attributes include the iSCSI vendor and version, as well
as information on the last target or initiator at the other end of a
session that caused a session failure.
The iscsiInstanceSsnErrorStatsTable augments the attributes table and
provides statistics on session failures due to digest, connection, or
iSCSI format errors.
6.4. iscsiPortal
The iscsiPortalAttributesTable lists iSCSI portals that can be used
to listen for connections to targets, to initiate connections to
other targets, or to do both.
Each row in the table includes an IP address (either v4 or v6), and a
transport protocol (currently only TCP is defined). Each portal may
have additional attributes, depending on whether it is an initiator
portal, a target portal, or both. Initiator portals also have portal
tags; these are placed in corresponding rows in the
iscsiIntrPortalAttributesTable. Target portals have both portal tags
and ports (e.g., TCP listen ports if the transport protocol is TCP);
these are placed in rows in the iscsiTgtPortalAttributesTable.
Bakke & Venkatesen Standards Track [Page 9]
RFC 7147 iSCSI MIB April 2014
Portal rows, along with their initiator and target portal
counterparts, may be created and destroyed through this MIB module by
a management station. Rows in the initiator and target portal tables
are created and destroyed automatically by the agent when a row is
created or destroyed in the iscsiPortalAttributesTable or when the
value of iscsiPortalRoles changes. Attributes in these tables may
then be modified by the management station if the agent
implementation allows.
When created by a management station, the iscsiPortalRoles attribute
is used to control row creation in the initiator and target portal
tables. Creating a row with the targetTypePortal bit set in
iscsiPortalRoles will cause the implementation to start listening for
iSCSI connections on the portal. Creating a row with the
initiatorTypePortal bit set in iscsiPortalRoles will not necessarily
cause connections to be established; it is left to the implementation
whether and when to make use of the portal. Both bits may be set if
the portal is to be used by both initiator and target nodes.
When deleting a row in the iscsiPortalAttibutesTable, all connections
associated with that row are terminated. The implementation may
either terminate the connection immediately or request a clean
shutdown as specified in [RFC7143]. An outbound connection (when an
iscsiInitiatorPortal is deleted) matches the portal if its
iscsiCxnLocalAddr matches the iscsiPortalAddr. An inbound connection
(when an iscsiTargetPortal is deleted) matches the portal if its
iscsiCxnLocalAddr matches the iscsiPortalAddr and if its
iscsiCxnLocalPort matches the iscsiTargetPortalPort.
Individual objects within a row in this table may not be modified
while the row is active. For instance, changing the IP address of a
portal requires that the rows associated with the old IP address be
deleted and that new rows be created (in either order).
6.5. iscsiTargetPortal
The iscsiTgtPortalAttributesTable contains target-specific attributes
for iSCSI portals. Rows in this table use the same indices as their
corresponding rows in the iscsiPortalAttributesTable, with the
addition of iscsiNodeIndex.
Rows in this table are created when the targetTypePortal bit is set
in the iscsiPortalRoles attribute of the corresponding
iscsiPortalAttributesEntry; they are destroyed when this bit is
cleared.
Bakke & Venkatesen Standards Track [Page 10]
RFC 7147 iSCSI MIB April 2014
This table contains the TCP (or other protocol) port on which the
socket is listening for incoming connections. It also includes a
portal group aggregation tag; iSCSI target portals that are within
this instance and share the same tag can contain connections within
the same session.
This table will be empty for iSCSI instances that contain only
initiators (such as iSCSI host driver implementations).
Many implementations use the same Target Portal Group Tag and
protocol port for all nodes accessed via a portal. These
implementations will create a single row in the
iscsiTgtPortalAttributeTable, with an iscsiNodeIndex of zero.
Other implementations do not use the same tag and/or port for all
nodes; these implementations will create a row in this table for each
(portal, node) tuple, using iscsiNodeIndex to designate the node for
this portal tag and port.
6.6. iscsiInitiatorPortal
The iscsiIntrPortalAttributesTable contains initiator-specific
objects for iSCSI portals. Rows in this table use the same indices
as their corresponding entries in the iscsiPortalAttributesTable. A
row in this table is created when the initiatorTypePortal bit is set
in the iscsiPortalRoles attribute; it is destroyed when this bit is
cleared.
Each row in this table contains a portal group aggregation tag,
indicating which portals an initiator may use together within a
multiple-connection session.
This table will be empty for iSCSI instances that contain only
targets (such as most iSCSI devices).
Many implementations use the same initiator tag for all nodes
accessing targets via a given portal. These implementations will
create a single row in iscsiIntrPortalAttributeTable, with an
iscsiNodeIndex of zero.
Other implementations do not use the same tag and/or port for all
nodes; these implementations will create a row in this table for each
(portal, node) tuple, using iscsiNodeIndex to designate the node for
this portal tag and port.
Bakke & Venkatesen Standards Track [Page 11]
RFC 7147 iSCSI MIB April 2014
6.7. iscsiNode
The iscsiNodeAttributesTable contains a list of iSCSI nodes, each of
which may have an initiator role, a target role, or both.
This table contains the node's attributes that are common to both
roles, such as its iSCSI name and alias string. Attributes specific
to initiators or targets are available in the iscsiTarget and
iscsiInitiator objects. Each row in this table that can fulfill a
target role has a corresponding row in the iscsiTarget table; each
entry that fulfills an initiator role has a row in the iscsiInitiator
table. Nodes such as copy managers that can take on both roles have
a corresponding row in each table.
This table also contains the login negotiations preferences for this
node. These objects indicate the values this node will offer or
prefer in the operational negotiation phase of the login process.
For most implementations, each entry in the table also contains a
RowPointer to the transport table entry in the SCSI MIB module that
this iSCSI node represents. For implementations without a standard
SCSI layer above iSCSI, such as an iSCSI proxy or gateway, this
RowPointer can point to a row in an implementation-specific table
that this iSCSI node represents.
6.8. iscsiTarget
The iscsiTargetAttributesTable contains target-specific attributes
for iSCSI nodes. Each entry in this table uses the same index values
as its corresponding iscsiNode entry.
This table contains attributes used to indicate the last failure that
was (or should have been) sent as a notification.
This table is augmented by the iscsiTargetLoginStatsTable and the
iscsiTargetLogoutStatsTable, which count the numbers of normal and
abnormal logins and logouts to this target.
6.9. iscsiTgtAuthorization
The iscsiTgtAuthAttributesTable contains an entry for each initiator
identifier that will be allowed to access the target under which it
appears. Each entry contains a RowPointer to a user identity in the
IPS Authorization MIB module, which contains the name, address, and
credential information necessary to authenticate the initiator.
Bakke & Venkatesen Standards Track [Page 12]
RFC 7147 iSCSI MIB April 2014
6.10. iscsiInitiator
The iscsiInitiatorAttributesTable contains a list of initiator-
specific attributes for iSCSI nodes. Each entry in this table uses
the same index values as its corresponding iscsiNode entry.
Most implementations will include a single entry in this table,
regardless of the number of physical interfaces the initiator may
use.
This table is augmented by the iscsiInitiatorLoginStatsTable and the
iscsiInitiatorLogoutStatsTable, which count the numbers of normal and
abnormal logins and logouts from this initiator.
6.11. iscsiIntrAuthorization
The iscsiIntrAuthAttributesTable contains an entry for each target
identifier to which the initiator is configured to establish a
session.
Each entry contains a RowPointer to a user identity in the IPS
Authorization MIB module, which contains the name, address, and
credential information necessary to identify (for discovery purposes)
and authenticate the target.
6.12. iscsiSession
The iscsiSessionAttributesTable contains a set of rows that list the
sessions known to exist locally for each node in each iSCSI instance.
The session type for each session indicates whether the session is
used for normal SCSI commands or for discovery using the SendTargets
text command. Discovery sessions that do not belong to any
particular node have a node index attribute of zero.
The session direction for each session indicates whether it is an
Inbound session or an Outbound session. Inbound sessions are from
some other initiator to the target node under which the session
appears. Outbound sessions are from the initiator node under which
the session appears to a target outside this iSCSI instance.
Many attributes may be negotiated when starting an iSCSI session.
Most of these attributes are included in the session object.
Bakke & Venkatesen Standards Track [Page 13]
RFC 7147 iSCSI MIB April 2014
Some attributes, such as the integrity and authentication schemes,
have some standard values that can be extended by vendors to include
their own schemes. These contain an object identifier, rather than
the expected enumerated type, to allow these values to be extended by
other MIB modules, such as an enterprise MIB module.
The iscsiSessionStatsTable includes statistics related to
performance; it counts iSCSI data bytes and PDUs.
For implementations that support error recovery without terminating a
session, the iscsiSessionCxnErrorStatsTable contains counters for the
numbers of digest and connection errors that have occurred within the
session.
6.13. iscsiConnection
The iscsiConnectionAttributesTable contains a list of active
connections within each session. It contains the IP addresses and
TCP (or other protocol) ports of both the local and remote sides of
the connection. These may be used to locate other connection-related
information and statistics in the TCP MIB module [RFC4022].
The attributes table also contains a connection state. This state is
not meant to directly map to the state tables included within the
iSCSI specification; they are meant to be simplified, higher-level
definitions of connection state that provide information more useful
to a user or network manager.
No statistics are kept for connections.
6.14. IP Addresses and TCP Port Numbers
The IP addresses in this module are represented by two attributes,
one of type InetAddressType, and the other of type InetAddress.
These are taken from [RFC4001], which specifies how to support
addresses that may be either IPv4 or IPv6.
The TCP port numbers that appear in a few of the structures are
described as simply port numbers, with a protocol attribute
indicating whether they are TCP ports or something else. This will
allow the module to be compatible with iSCSI over transports other
than TCP in the future.
Bakke & Venkatesen Standards Track [Page 14]
RFC 7147 iSCSI MIB April 2014
6.15. Descriptors: Using OIDs in Place of Enumerated Types
The iSCSI MIB module has a few attributes, namely, the digest method
attributes, where an enumerated type would work well, except that an
implementation may need to extend the attribute and add types of its
own. To make this work, this MIB module defines a set of object
identities within the iscsiDescriptors subtree. Each of these object
identities is basically an enumerated type.
Attributes that make use of these object identities have a value that
is an Object Identifier (OID) instead of an enumerated type. These
OIDs can indicate either the object identities defined in this module
or object identities defined elsewhere, such as in an enterprise MIB
module. Those implementations that add their own digest methods
should also define a corresponding object identity for each of these
methods within their own enterprise MIB module, and return its OID
whenever one of these attributes is using that method.
6.16. Notifications
Three notifications are provided. One is sent by an initiator
detecting a critical login failure, another is sent by a target
detecting a critical login failure, and the third is sent upon a
session being terminated due to an abnormal connection or digest
failure. Critical failures are defined as those that may expose
security-related problems that may require immediate action, such as
failures due to authentication, authorization, or negotiation
problems. Attributes in the initiator, target, and instance objects
provide the information necessary to send in the notification, such
as the initiator or target name and IP address at the other end that
may have caused the failure.
To avoid sending an excessive number of notifications due to multiple
errors counted, an SNMP agent implementing the iSCSI MIB module
SHOULD NOT send more than three iSCSI notifications in any 10-second
period.
The 3-in-10 rule was chosen because one notification every three
seconds was deemed often enough, but should two or three different
notifications happen at the same time, it would not be desirable to
suppress them. Three notifications in 10 seconds is a happy medium,
where a short burst of notifications is allowed, without inundating
the network and/or notification host with a large number of
notifications.
Bakke & Venkatesen Standards Track [Page 15]
RFC 7147 iSCSI MIB April 2014
7. MIB Definition
ISCSI-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY, NOTIFICATION-TYPE,
Unsigned32, Counter32, Counter64, Gauge32,
mib-2
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, TruthValue, RowPointer, TimeStamp, RowStatus,
AutonomousType, StorageType
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB -- RFC 3411
InetAddressType, InetAddress, InetPortNumber
FROM INET-ADDRESS-MIB -- RFC 4001
;
iscsiMibModule MODULE-IDENTITY
LAST-UPDATED "201402180000Z" -- February 18, 2014
ORGANIZATION "IETF STORage Maintenance (STORM) Working Group"
CONTACT-INFO "
Working Group Email: storm@ietf.org
Attn: Mark Bakke
Dell
Email: mark_bakke@dell.com
Prakash Venkatesen
HCL Technologies
Email: prakashvn@hcl.com"
DESCRIPTION
"This module defines management information specific
to the iSCSI protocol.
Copyright (c) 2014 IETF Trust and the persons identified as
authors of the code. All rights reserved.
Redistribution and use in source and binary forms, with or
without modification, is permitted pursuant to, and subject
to the license terms contained in, the Simplified BSD
Bakke & Venkatesen Standards Track [Page 16]
RFC 7147 iSCSI MIB April 2014
License set forth in Section 4.c of the IETF Trust's Legal
Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info)."
REVISION "201402180000Z"
DESCRIPTION
"Second version of the iSCSI Protocol MIB Module.
RFC 7143 makes several updates to [RFC3720]. This
version makes corresponding updates to the MIB module.
This MIB module published as RFC 7147."
REVISION "200605220000Z"
DESCRIPTION
"Initial version of the iSCSI Protocol MIB module.
This MIB module published as RFC 4544."
::= { mib-2 142 }
iscsiNotifications OBJECT IDENTIFIER ::= { iscsiMibModule 0 }
iscsiObjects OBJECT IDENTIFIER ::= { iscsiMibModule 1 }
iscsiConformance OBJECT IDENTIFIER ::= { iscsiMibModule 2 }
iscsiAdmin OBJECT IDENTIFIER ::= { iscsiMibModule 3 }
-- Textual Conventions
IscsiTransportProtocol ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"This data type is used to define the transport
protocols that will carry iSCSI PDUs.
Protocol numbers are assigned by IANA. A
current list of all assignments is available from
<http://www.iana.org/assignments/protocol-numbers/>."
SYNTAX Unsigned32 (0..255)
IscsiDigestMethod ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This data type represents the methods possible
for digest negotiation.
none - a placeholder for a secondary digest method
that means only the primary method can be
used.
other - a digest method other than those defined below.
noDigest - does not support digests (will operate without
a digest (Note: implementations must support
digests to be compliant with RFC 7143).
CRC32c - require a CRC32C digest."
Bakke & Venkatesen Standards Track [Page 17]
RFC 7147 iSCSI MIB April 2014
REFERENCE
"RFC 7143, Section 13.1, HeaderDigest and DataDigest"
SYNTAX INTEGER {
none(1),
other(2),
noDigest(3),
crc32c(4)
}
IscsiName ::= TEXTUAL-CONVENTION
DISPLAY-HINT "223t"
STATUS current
DESCRIPTION
"This data type is used for objects whose value is an
iSCSI name with the properties described in RFC 7143,
Section 4.2.7.1, and encoded as specified in RFC 7143,
Section 4.2.7.2. A zero-length string indicates the
absence of an iSCSI name."
REFERENCE
"RFC 7143, Section 4.2.7, iSCSI Names."
SYNTAX OCTET STRING (SIZE(0 | 16..223))
--**********************************************************************
iscsiDescriptors OBJECT IDENTIFIER ::= { iscsiAdmin 1 }
iscsiHeaderIntegrityTypes OBJECT IDENTIFIER ::= { iscsiDescriptors 1 }
iscsiHdrIntegrityNone OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The authoritative identifier when no integrity
scheme for the header is being used."
REFERENCE
"RFC 7143, Section 13.1, HeaderDigest and DataDigest"
::= { iscsiHeaderIntegrityTypes 1 }
iscsiHdrIntegrityCrc32c OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The authoritative identifier when the integrity
scheme for the header is CRC32c."
REFERENCE
"RFC 7143, Section 13.1, HeaderDigest and DataDigest"
::= { iscsiHeaderIntegrityTypes 2 }
iscsiDataIntegrityTypes OBJECT IDENTIFIER ::= { iscsiDescriptors 2 }
Bakke & Venkatesen Standards Track [Page 18]
RFC 7147 iSCSI MIB April 2014
iscsiDataIntegrityNone OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The authoritative identifier when no integrity
scheme for the data is being used."
REFERENCE
"RFC 7143, Section 13.1, HeaderDigest and DataDigest"
::= { iscsiDataIntegrityTypes 1 }
iscsiDataIntegrityCrc32c OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The authoritative identifier when the integrity
scheme for the data is CRC32c."
REFERENCE
"RFC 7143, Section 13.1, HeaderDigest and DataDigest"
::= { iscsiDataIntegrityTypes 2 }
--**********************************************************************
iscsiInstance OBJECT IDENTIFIER ::= { iscsiObjects 1 }
-- Instance Attributes Table
iscsiInstanceAttributesTable OBJECT-TYPE
SYNTAX SEQUENCE OF IscsiInstanceAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of iSCSI instances present on the system."
::= { iscsiInstance 1 }
iscsiInstanceAttributesEntry OBJECT-TYPE
SYNTAX IscsiInstanceAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (row) containing management information applicable
to a particular iSCSI instance."
INDEX { iscsiInstIndex }
::= { iscsiInstanceAttributesTable 1 }
IscsiInstanceAttributesEntry ::= SEQUENCE {
iscsiInstIndex Unsigned32,
iscsiInstDescr SnmpAdminString,
iscsiInstVersionMin Unsigned32,
iscsiInstVersionMax Unsigned32,
iscsiInstVendorID SnmpAdminString,
Bakke & Venkatesen Standards Track [Page 19]
RFC 7147 iSCSI MIB April 2014
iscsiInstVendorVersion SnmpAdminString,
iscsiInstPortalNumber Unsigned32,
iscsiInstNodeNumber Unsigned32,
iscsiInstSessionNumber Unsigned32,
iscsiInstSsnFailures Counter32,
iscsiInstLastSsnFailureType AutonomousType,
iscsiInstLastSsnRmtNodeName IscsiName,
iscsiInstDiscontinuityTime TimeStamp,
iscsiInstXNodeArchitecture SnmpAdminString
}
iscsiInstIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer used to uniquely identify a particular
iSCSI instance. This index value must not be modified or
reused by an agent unless a reboot has occurred. An agent
should attempt to keep this value persistent across reboots."
::= { iscsiInstanceAttributesEntry 1 }
iscsiInstDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A UTF-8 string, determined by the implementation to
describe the iSCSI instance. When only a single instance
is present, this object may be set to the zero-length
string; with multiple iSCSI instances, it may be used in
an implementation-dependent manner to describe the purpose
of the respective instance."
::= { iscsiInstanceAttributesEntry 2 }
iscsiInstVersionMin OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum version number of the iSCSI specification
such that this iSCSI instance supports this minimum
value, the maximum value indicated by the corresponding
instance in iscsiInstVersionMax, and all versions in
between."
REFERENCE
"RFC 7143, Section 11.12, Login Request"
Bakke & Venkatesen Standards Track [Page 20]
RFC 7147 iSCSI MIB April 2014
::= { iscsiInstanceAttributesEntry 3 }
iscsiInstVersionMax OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum version number of the iSCSI specification
such that this iSCSI instance supports this maximum
value, the minimum value indicated by the corresponding
instance in iscsiInstVersionMin, and all versions in
between."
REFERENCE
"RFC 7143, Section 11.12, Login Request"
::= { iscsiInstanceAttributesEntry 4 }
iscsiInstVendorID OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A UTF-8 string describing the manufacturer of the
implementation of this instance."
::= { iscsiInstanceAttributesEntry 5 }
iscsiInstVendorVersion OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A UTF-8 string set by the manufacturer describing the
version of the implementation of this instance. The
format of this string is determined solely by the
manufacturer; the string is for informational purposes only.
It is unrelated to the iSCSI specification version numbers."
::= { iscsiInstanceAttributesEntry 6 }
iscsiInstPortalNumber OBJECT-TYPE
SYNTAX Unsigned32
UNITS "transport endpoints"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of rows in the iscsiPortalAttributesTable
that are currently associated with this iSCSI instance."
::= { iscsiInstanceAttributesEntry 7 }
iscsiInstNodeNumber OBJECT-TYPE
Bakke & Venkatesen Standards Track [Page 21]
RFC 7147 iSCSI MIB April 2014
SYNTAX Unsigned32
UNITS "iSCSI nodes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of rows in the iscsiNodeAttributesTable
that are currently associated with this iSCSI instance."
::= { iscsiInstanceAttributesEntry 8 }
iscsiInstSessionNumber OBJECT-TYPE
SYNTAX Unsigned32
UNITS "sessions"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of rows in the iscsiSessionAttributesTable
that are currently associated with this iSCSI instance."
::= { iscsiInstanceAttributesEntry 9 }
iscsiInstSsnFailures OBJECT-TYPE
SYNTAX Counter32
UNITS "sessions"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object counts the number of times a session belonging
to this instance has failed. If this counter has
suffered a discontinuity, the time of the last discontinuity
is indicated in iscsiInstDiscontinuityTime."
REFERENCE
"RFC 7143, Section 13.1, HeaderDigest and DataDigest"
::= { iscsiInstanceAttributesEntry 10 }
iscsiInstLastSsnFailureType OBJECT-TYPE
SYNTAX AutonomousType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter object in the iscsiInstanceSsnErrorStatsTable
that was incremented when the last session failure occurred.
If the reason for failure is not found in the
iscsiInstanceSsnErrorStatsTable, the value { 0.0 } is
used instead."
::= { iscsiInstanceAttributesEntry 11 }
iscsiInstLastSsnRmtNodeName OBJECT-TYPE
SYNTAX IscsiName
Bakke & Venkatesen Standards Track [Page 22]
RFC 7147 iSCSI MIB April 2014
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The iSCSI name of the remote node from the failed
session."
::= { iscsiInstanceAttributesEntry 12 }
iscsiInstDiscontinuityTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of SysUpTime on the most recent occasion
at which any one or more of this instance's counters
suffered a discontinuity.
If no such discontinuities have occurred since the last
re-initialization of the local management subsystem,
then this object contains a zero value."
::= { iscsiInstanceAttributesEntry 13 }
iscsiInstXNodeArchitecture OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A UTF-8 string set by the manufacturer declaring the
details of its iSCSI node architecture to the remote
endpoint. These details may include, but are not limited
to, iSCSI vendor software, firmware, or hardware versions,
the OS version, or hardware architecture.
The format of this string is determined solely by the
manufacturer; the string is for informational purposes only.
It is unrelated to the iSCSI specification version numbers."
REFERENCE
"RFC 7143, Section 13.26, X#NodeArchitecture"
::= { iscsiInstanceAttributesEntry 14 }
-- Instance Session Failure Stats Table
iscsiInstanceSsnErrorStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF IscsiInstanceSsnErrorStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Statistics regarding the occurrences of error types
that result in a session failure."
::= { iscsiInstance 2 }
Bakke & Venkatesen Standards Track [Page 23]
RFC 7147 iSCSI MIB April 2014
iscsiInstanceSsnErrorStatsEntry OBJECT-TYPE
SYNTAX IscsiInstanceSsnErrorStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (row) containing management information applicable
to a particular iSCSI instance."
AUGMENTS { iscsiInstanceAttributesEntry }
::= { iscsiInstanceSsnErrorStatsTable 1 }
IscsiInstanceSsnErrorStatsEntry ::= SEQUENCE {
iscsiInstSsnDigestErrors Counter32,
iscsiInstSsnCxnTimeoutErrors Counter32,
iscsiInstSsnFormatErrors Counter32,
iscsiInstSsnTgtUnmappedErrors Counter32
}
iscsiInstSsnDigestErrors OBJECT-TYPE
SYNTAX Counter32
UNITS "sessions"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of sessions that failed due to receipt of
a PDU containing header or data digest errors. If this
counter has suffered a discontinuity, the time of the last
discontinuity is indicated in iscsiInstDiscontinuityTime."
REFERENCE
"RFC 7143, Section 7.8, Digest Errors"
::= { iscsiInstanceSsnErrorStatsEntry 1 }
iscsiInstSsnCxnTimeoutErrors OBJECT-TYPE
SYNTAX Counter32
UNITS "sessions"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of sessions that failed due to a sequence
exceeding a time limit. If this counter has suffered a
discontinuity, the time of the last discontinuity
is indicated in iscsiInstDiscontinuityTime."
REFERENCE
"RFC 7143, Section 7.5, Connection Timeout Management"
::= { iscsiInstanceSsnErrorStatsEntry 2 }
iscsiInstSsnFormatErrors OBJECT-TYPE
SYNTAX Counter32
UNITS "sessions"
Bakke & Venkatesen Standards Track [Page 24]
RFC 7147 iSCSI MIB April 2014
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of sessions that failed due to receipt of
a PDU that contained a format error. If this counter has
suffered a discontinuity, the time of the last discontinuity
is indicated in iscsiInstDiscontinuityTime."
REFERENCE
"RFC 7143 Section 7.7, Format Errors"
::= { iscsiInstanceSsnErrorStatsEntry 3 }
iscsiInstSsnTgtUnmappedErrors OBJECT-TYPE
SYNTAX Counter32
UNITS "sessions"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of sessions that failed due to the target
becoming unmapped. If this counter has
suffered a discontinuity, the time of the last discontinuity
is indicated in iscsiInstDiscontinuityTime."
::= { iscsiInstanceSsnErrorStatsEntry 4 }
--**********************************************************************
iscsiPortal OBJECT IDENTIFIER ::= { iscsiObjects 2 }
-- Portal Attributes Table
iscsiPortalAttributesTable OBJECT-TYPE
SYNTAX SEQUENCE OF IscsiPortalAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of transport endpoints (using TCP or another transport
protocol) used by this iSCSI instance. An iSCSI instance may
use a portal to listen for incoming connections to its targets,
to initiate connections to other targets, or both."
::= { iscsiPortal 1 }
iscsiPortalAttributesEntry OBJECT-TYPE
SYNTAX IscsiPortalAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (row) containing management information applicable
to a particular portal instance."
INDEX { iscsiInstIndex, iscsiPortalIndex }
::= { iscsiPortalAttributesTable 1 }
Bakke & Venkatesen Standards Track [Page 25]
RFC 7147 iSCSI MIB April 2014
IscsiPortalAttributesEntry ::= SEQUENCE {
iscsiPortalIndex Unsigned32,
iscsiPortalRowStatus RowStatus,
iscsiPortalRoles BITS,
iscsiPortalAddrType InetAddressType,
iscsiPortalAddr InetAddress,
iscsiPortalProtocol IscsiTransportProtocol,
iscsiPortalMaxRecvDataSegLength Unsigned32,
iscsiPortalPrimaryHdrDigest IscsiDigestMethod,
iscsiPortalPrimaryDataDigest IscsiDigestMethod,
iscsiPortalSecondaryHdrDigest IscsiDigestMethod,
iscsiPortalSecondaryDataDigest IscsiDigestMethod,
iscsiPortalRecvMarker TruthValue,
iscsiPortalStorageType StorageType,
iscsiPortalDescr SnmpAdminString
}
iscsiPortalIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer used to uniquely identify a particular
transport endpoint within this iSCSI instance. This index
value must not be modified or reused by an agent unless a
reboot has occurred. An agent should attempt to keep this
value persistent across reboots."
::= { iscsiPortalAttributesEntry 1 }
iscsiPortalRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This field allows entries to be dynamically added and
removed from this table via SNMP. When adding a row to
this table, all non-Index/RowStatus objects must be set.
When the value of this object is 'active', the values of
the other objects in this table cannot be changed.
Rows may be discarded using RowStatus.
Note that creating a row in this table will typically
cause the agent to create one or more rows in the
iscsiTgtPortalAttributesTable and/or the
iscsiIntrPortalAttributesTable."
::= { iscsiPortalAttributesEntry 2 }
iscsiPortalRoles OBJECT-TYPE
Bakke & Venkatesen Standards Track [Page 26]
RFC 7147 iSCSI MIB April 2014
SYNTAX BITS {
targetTypePortal(0),
initiatorTypePortal(1)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A portal can operate in one or both of two roles:
as a target portal and/or an initiator portal. If
the portal will operate in both roles, both bits
must be set.
This object will define a corresponding row that
will exist or must be created in the
iscsiTgtPortalAttributesTable, the
iscsiIntrPortalAttributesTable, or both. If the
targetTypePortal bit is set, one or more corresponding
iscsiTgtPortalAttributesEntry rows will be found or
created. If the initiatorTypePortal bit is set,
one or more corresponding iscsiIntrPortalAttributesEntry
rows will be found or created. If both bits are set, one
or more corresponding rows will be found or created in
one of the above tables."
::= { iscsiPortalAttributesEntry 3 }
iscsiPortalAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of Internet Network Address contained in the
corresponding instance of the iscsiPortalAddr."
DEFVAL { ipv4 }
::= { iscsiPortalAttributesEntry 4 }
iscsiPortalAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The portal's Internet Network Address, of the type
specified by the object iscsiPortalAddrType. If
iscsiPortalAddrType has the value 'dns', this address
gets resolved to an IP address whenever a new iSCSI
connection is established using this portal."
::= { iscsiPortalAttributesEntry 5 }
iscsiPortalProtocol OBJECT-TYPE
Bakke & Venkatesen Standards Track [Page 27]
RFC 7147 iSCSI MIB April 2014
SYNTAX IscsiTransportProtocol
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The portal's transport protocol."
DEFVAL { 6 } -- TCP
::= { iscsiPortalAttributesEntry 6 }
iscsiPortalMaxRecvDataSegLength OBJECT-TYPE
SYNTAX Unsigned32 (512..16777215)
UNITS "bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum PDU length this portal can receive.
This may be constrained by hardware characteristics,
and individual implementations may choose not to
allow this object to be changed."
REFERENCE
"RFC 7143, Section 13.12, MaxRecvDataSegmentLength"
DEFVAL { 8192 }
::= { iscsiPortalAttributesEntry 7 }
iscsiPortalPrimaryHdrDigest OBJECT-TYPE
SYNTAX IscsiDigestMethod
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The preferred header digest for this portal."
DEFVAL { crc32c }
::= { iscsiPortalAttributesEntry 8 }
iscsiPortalPrimaryDataDigest OBJECT-TYPE
SYNTAX IscsiDigestMethod
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The preferred data digest method for this portal."
DEFVAL { crc32c }
::= { iscsiPortalAttributesEntry 9 }
iscsiPortalSecondaryHdrDigest OBJECT-TYPE
SYNTAX IscsiDigestMethod
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An alternate header digest preference for this portal."
DEFVAL { noDigest }
Bakke & Venkatesen Standards Track [Page 28]
RFC 7147 iSCSI MIB April 2014
::= { iscsiPortalAttributesEntry 10 }
iscsiPortalSecondaryDataDigest OBJECT-TYPE
SYNTAX IscsiDigestMethod
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An alternate data digest preference for this portal."
DEFVAL { noDigest }
::= { iscsiPortalAttributesEntry 11 }
iscsiPortalRecvMarker OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"This object indicates whether or not this portal will
request markers in its incoming data stream."
REFERENCE
"RFC 7143, Section 13.25, Obsoleted Keys."
DEFVAL { false }
::= { iscsiPortalAttributesEntry 12 }
iscsiPortalStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The storage type for this row. Rows in this table that were
created through an external process (e.g., not created via
this MIB) may have a storage type of readOnly or permanent.
Conceptual rows having the value 'permanent' need not
allow write access to any columnar objects in the row."
DEFVAL { nonVolatile }
::= { iscsiPortalAttributesEntry 13 }
iscsiPortalDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A UTF-8 string, determined by the implementation to
describe the iSCSI portal. When only a single instance
is present, this object may be set to the zero-length
string; with multiple iSCSI portals, it may be used in
an implementation-dependent manner to describe the
respective portal, and could include information such as
Bakke & Venkatesen Standards Track [Page 29]
RFC 7147 iSCSI MIB April 2014
Host Bus Adapter (HBA) model, description, and version, or
software driver and version."
::= { iscsiPortalAttributesEntry 14 }
--**********************************************************************
iscsiTargetPortal OBJECT IDENTIFIER ::= { iscsiObjects 3 }
-- Target Portal Attributes Table
iscsiTgtPortalAttributesTable OBJECT-TYPE
SYNTAX SEQUENCE OF IscsiTgtPortalAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of transport endpoints (using TCP or another transport
protocol) on which this iSCSI instance listens for incoming
connections to its targets."
::= { iscsiTargetPortal 1 }
iscsiTgtPortalAttributesEntry OBJECT-TYPE
SYNTAX IscsiTgtPortalAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (row) containing management information applicable
to a particular portal instance that is used to listen for
incoming connections to local targets. One or more rows in
this table is populated by the agent for each
iscsiPortalAttributesEntry row that has the bit
targetTypePortal set in its iscsiPortalRoles column."
INDEX { iscsiInstIndex, iscsiPortalIndex,
iscsiTgtPortalNodeIndexOrZero }
::= { iscsiTgtPortalAttributesTable 1 }
IscsiTgtPortalAttributesEntry ::= SEQUENCE {
iscsiTgtPortalNodeIndexOrZero Unsigned32,
iscsiTgtPortalPort InetPortNumber,
iscsiTgtPortalTag Unsigned32
}
iscsiTgtPortalNodeIndexOrZero OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer used to uniquely identify a
particular node within an iSCSI instance present
on the local system.
Bakke & Venkatesen Standards Track [Page 30]
RFC 7147 iSCSI MIB April 2014
For implementations where each {portal, node} tuple
can have a different portal tag, this value will
map to the iscsiNodeIndex.
For implementations where the portal tag is the
same for a given portal regardless of which node
is using the portal, the value 0 (zero) is used."
::= { iscsiTgtPortalAttributesEntry 1 }
iscsiTgtPortalPort OBJECT-TYPE
SYNTAX InetPortNumber (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The portal's transport protocol port number on which the
portal listens for incoming iSCSI connections when the
portal is used as a target portal. This object's storage
type is specified in iscsiPortalStorageType."
::= { iscsiTgtPortalAttributesEntry 2 }
iscsiTgtPortalTag OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The portal's aggregation tag when the portal is used as
a target portal. Multiple-connection sessions may
be aggregated over portals sharing an identical
aggregation tag. This object's storage type is
specified in iscsiPortalStorageType."
REFERENCE
"RFC 7143, Section 4.4.1, iSCSI Architecture Model"
::= { iscsiTgtPortalAttributesEntry 3 }
--**********************************************************************
iscsiInitiatorPortal OBJECT IDENTIFIER ::= { iscsiObjects 4 }
-- Initiator Portal Attributes Table
iscsiIntrPortalAttributesTable OBJECT-TYPE
SYNTAX SEQUENCE OF IscsiIntrPortalAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Internet Network Addresses (using TCP or another
transport protocol) from which this iSCSI instance may
initiate connections to other targets."
Bakke & Venkatesen Standards Track [Page 31]
RFC 7147 iSCSI MIB April 2014
::= { iscsiInitiatorPortal 1 }
iscsiIntrPortalAttributesEntry OBJECT-TYPE
SYNTAX IscsiIntrPortalAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (row) containing management information applicable
to a particular portal instance that is used to initiate
connections to iSCSI targets. One or more rows in
this table is populated by the agent for each
iscsiPortalAttributesEntry row that has the bit
initiatorTypePortal set in its iscsiPortalRoles column."
INDEX { iscsiInstIndex, iscsiPortalIndex,
iscsiIntrPortalNodeIndexOrZero }
::= { iscsiIntrPortalAttributesTable 1 }
IscsiIntrPortalAttributesEntry ::= SEQUENCE {
iscsiIntrPortalNodeIndexOrZero Unsigned32,
iscsiIntrPortalTag Unsigned32
}
iscsiIntrPortalNodeIndexOrZero OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer used to uniquely identify a
particular node within an iSCSI instance present
on the local system.
For implementations where each {portal, node} tuple
can have a different portal tag, this value will
map to the iscsiNodeIndex.
For implementations where the portal tag is the
same for a given portal regardless of which node
is using the portal, the value 0 (zero) is used."
::= { iscsiIntrPortalAttributesEntry 1 }
iscsiIntrPortalTag OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The portal's aggregation tag when the portal is used as
an initiator portal. Multiple-connection sessions may
be aggregated over portals sharing an identical
Bakke & Venkatesen Standards Track [Page 32]
RFC 7147 iSCSI MIB April 2014
aggregation tag. This object's storage type is
specified in iscsiPortalStorageType."
REFERENCE
"RFC 7143, Section 4.4.1, iSCSI Architecture Model"
::= { iscsiIntrPortalAttributesEntry 2 }
--**********************************************************************
iscsiNode OBJECT IDENTIFIER ::= { iscsiObjects 5 }
-- Node Attributes Table
iscsiNodeAttributesTable OBJECT-TYPE
SYNTAX SEQUENCE OF IscsiNodeAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of iSCSI nodes belonging to each iSCSI instance
present on the local system. An iSCSI node can act as
an initiator, a target, or both."
::= { iscsiNode 1 }
iscsiNodeAttributesEntry OBJECT-TYPE
SYNTAX IscsiNodeAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row containing management information
applicable to a particular iSCSI node."
INDEX { iscsiInstIndex, iscsiNodeIndex }
::= { iscsiNodeAttributesTable 1 }
IscsiNodeAttributesEntry ::= SEQUENCE {
iscsiNodeIndex Unsigned32,
iscsiNodeName IscsiName,
iscsiNodeAlias SnmpAdminString,
iscsiNodeRoles BITS,
iscsiNodeTransportType RowPointer,
iscsiNodeInitialR2T TruthValue,
iscsiNodeImmediateData TruthValue,
iscsiNodeMaxOutstandingR2T Unsigned32,
iscsiNodeFirstBurstLength Unsigned32,
iscsiNodeMaxBurstLength Unsigned32,
iscsiNodeMaxConnections Unsigned32,
iscsiNodeDataSequenceInOrder TruthValue,
iscsiNodeDataPDUInOrder TruthValue,
iscsiNodeDefaultTime2Wait Unsigned32,
iscsiNodeDefaultTime2Retain Unsigned32,
Bakke & Venkatesen Standards Track [Page 33]
RFC 7147 iSCSI MIB April 2014
iscsiNodeErrorRecoveryLevel Unsigned32,
iscsiNodeDiscontinuityTime TimeStamp,
iscsiNodeStorageType StorageType
}
iscsiNodeIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer used to uniquely identify a particular
node within an iSCSI instance. This index value must not be
modified or reused by an agent unless a reboot has occurred.
An agent should attempt to keep this value persistent across
reboots."
::= { iscsiNodeAttributesEntry 1 }
iscsiNodeName OBJECT-TYPE
SYNTAX IscsiName
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This node's iSCSI name, which is independent of the location
of the node, and can be resolved into a set of addresses
through various discovery services."
::= { iscsiNodeAttributesEntry 2 }
iscsiNodeAlias OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A character string that is a human-readable name or
description of the iSCSI node. If configured, this alias
may be communicated to the initiator or target node at
the remote end of the connection during a Login Request
or Response message. This string is not used as an
identifier, but it can be displayed by the system's user
interface in a list of initiators and/or targets to
which it is connected.
If no alias exists, the value is a zero-length string."
REFERENCE
"RFC 7143, Sections 13.6 (TargetAlias) and 13.7
(InitiatorAlias)"
::= { iscsiNodeAttributesEntry 3 }
iscsiNodeRoles OBJECT-TYPE
Bakke & Venkatesen Standards Track [Page 34]
RFC 7147 iSCSI MIB April 2014
SYNTAX BITS {
targetTypeNode(0),
initiatorTypeNode(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A node can operate in one or both of two roles:
a target role and/or an initiator role. If the node
will operate in both roles, both bits must be set.
This object will also define the corresponding rows that
will exist in the iscsiTargetAttributesTable, the
iscsiInitiatorAttributesTable, or both. If the
targetTypeNode bit is set, there will be a corresponding
iscsiTargetAttributesEntry. If the initiatorTypeNode bit
is set, there will be a corresponding
iscsiInitiatorAttributesEntry. If both bits are set,
there will be a corresponding iscsiTgtPortalAttributesEntry
and iscsiPortalAttributesEntry."
::= { iscsiNodeAttributesEntry 4 }
iscsiNodeTransportType OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A pointer to the corresponding row in the appropriate
table for this SCSI transport, thereby allowing management
stations to locate the SCSI-level device that is represented
by this iscsiNode. For example, it will usually point to the
corresponding scsiTrnspt object in the SCSI MIB module.
If no corresponding row exists, the value 0.0 must be
used to indicate this."
REFERENCE
"SCSI-MIB, RFC 4455, Section 9, Object Definitions,
scsiTransportTypes"
::= { iscsiNodeAttributesEntry 5 }
iscsiNodeInitialR2T OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the InitialR2T preference for this
node:
true = YES,
false = will try to negotiate NO, will accept YES "
Bakke & Venkatesen Standards Track [Page 35]
RFC 7147 iSCSI MIB April 2014
REFERENCE
"RFC 7143, Section 13.10, InitialR2T"
::= { iscsiNodeAttributesEntry 6 }
iscsiNodeImmediateData OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates ImmediateData preference for this
node:
true = YES (but will accept NO),
false = NO "
REFERENCE
"RFC 7143, Section 13.11, ImmediateData"
DEFVAL { true }
::= { iscsiNodeAttributesEntry 7 }
iscsiNodeMaxOutstandingR2T OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
UNITS "R2Ts"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum number of outstanding requests-to-transmit (R2Ts)
allowed per iSCSI task."
REFERENCE
"RFC 7143, Section 13.17, MaxOutstandingR2T"
DEFVAL { 1 }
::= { iscsiNodeAttributesEntry 8 }
iscsiNodeFirstBurstLength OBJECT-TYPE
SYNTAX Unsigned32 (512..16777215)
UNITS "bytes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum length (bytes) supported for unsolicited data
to/from this node."
REFERENCE
"RFC 7143, Section 13.14, FirstBurstLength"
DEFVAL { 65536 }
::= { iscsiNodeAttributesEntry 9 }
iscsiNodeMaxBurstLength OBJECT-TYPE
SYNTAX Unsigned32 (512..16777215)
UNITS "bytes"
MAX-ACCESS read-write
Bakke & Venkatesen Standards Track [Page 36]
RFC 7147 iSCSI MIB April 2014
STATUS current
DESCRIPTION
"The maximum number of bytes that can be sent within
a single sequence of Data-In or Data-Out PDUs."
REFERENCE
"RFC 7143, Section 13.13, MaxBurstLength"
DEFVAL { 262144 }
::= { iscsiNodeAttributesEntry 10 }
iscsiNodeMaxConnections OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
UNITS "connections"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of connections allowed in each
session to and/or from this node."
REFERENCE
"RFC 7143, Section 13.2, MaxConnections"
DEFVAL { 1 }
::= { iscsiNodeAttributesEntry 11 }
iscsiNodeDataSequenceInOrder OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DataSequenceInOrder preference of this node.
False (=No) indicates that iSCSI data PDU sequences may
be transferred in any order. True (=Yes) indicates that
data PDU sequences must be transferred using
continuously increasing offsets, except during
error recovery."
REFERENCE
"RFC 7143, Section 13.19, DataSequenceInOrder"
DEFVAL { true }
::= { iscsiNodeAttributesEntry 12 }
iscsiNodeDataPDUInOrder OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DataPDUInOrder preference of this node.
False (=No) indicates that iSCSI data PDUs within sequences
may be in any order. True (=Yes) indicates that data PDUs
within sequences must be at continuously increasing
addresses, with no gaps or overlay between PDUs."
Bakke & Venkatesen Standards Track [Page 37]
RFC 7147 iSCSI MIB April 2014
REFERENCE
"RFC 7143, Section 13.18, DataPDUInOrder"
DEFVAL { true }
::= { iscsiNodeAttributesEntry 13 }
iscsiNodeDefaultTime2Wait OBJECT-TYPE
SYNTAX Unsigned32 (0..3600)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DefaultTime2Wait preference of this node. This is the
minimum time, in seconds, to wait before attempting an
explicit/implicit logout or active iSCSI task reassignment
after an unexpected connection termination or a connection
reset."
REFERENCE
"RFC 7143, Section 13.15, DefaultTime2Wait"
DEFVAL { 2 }
::= { iscsiNodeAttributesEntry 14 }
iscsiNodeDefaultTime2Retain OBJECT-TYPE
SYNTAX Unsigned32 (0..3600)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DefaultTime2Retain preference of this node. This is
the maximum time, in seconds after an initial wait
(Time2Wait), before which an active iSCSI task reassignment
is still possible after an unexpected connection termination
or a connection reset."
REFERENCE
"RFC 7143, Section 13.16, DefaultTime2Retain"
DEFVAL { 20 }
::= { iscsiNodeAttributesEntry 15 }
iscsiNodeErrorRecoveryLevel OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ErrorRecoveryLevel preference of this node.
Currently, only 0-2 are valid.
This object is designed to accommodate future error-recovery
levels.
Bakke & Venkatesen Standards Track [Page 38]
RFC 7147 iSCSI MIB April 2014
Higher error-recovery levels imply support in addition to
support for the lower error level functions. In other words,
error level 2 implies support for levels 0-1, since those
functions are subsets of error level 2."
REFERENCE
"RFC 7143, Section 13.20, ErrorRecoveryLevel"
DEFVAL { 0 }
::= { iscsiNodeAttributesEntry 16 }
iscsiNodeDiscontinuityTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of SysUpTime on the most recent occasion
at which any one or more of this node's counters
suffered a discontinuity.
If no such discontinuities have occurred since the last
re-initialization of the local management subsystem,
then this object contains a zero value."
::= { iscsiNodeAttributesEntry 17 }
iscsiNodeStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The storage type for all read-write objects within this
row. Rows in this table are always created via an
external process (e.g., not created via this MIB module).
Conceptual rows having the value 'permanent' need not allow
Write access to any columnar objects in the row.
If this object has the value 'volatile', modifications
to read-write objects in this row are not persistent
across reboots. If this object has the value
'nonVolatile', modifications to objects in this row
are persistent.
An implementation may choose to allow this object
to be set to either 'nonVolatile' or 'volatile',
allowing the management application to choose this
behavior."
DEFVAL { volatile }
::= { iscsiNodeAttributesEntry 18 }
--**********************************************************************
Bakke & Venkatesen Standards Track [Page 39]
RFC 7147 iSCSI MIB April 2014
iscsiTarget OBJECT IDENTIFIER ::= { iscsiObjects 6 }
-- Target Attributes Table
iscsiTargetAttributesTable OBJECT-TYPE
SYNTAX SEQUENCE OF IscsiTargetAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of iSCSI nodes that can take on a target role,
belonging to each iSCSI instance present on the local
system."
::= { iscsiTarget 1 }
iscsiTargetAttributesEntry OBJECT-TYPE
SYNTAX IscsiTargetAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (row) containing management information applicable
to a particular node that can take on a target role."
INDEX { iscsiInstIndex, iscsiNodeIndex }
::= { iscsiTargetAttributesTable 1 }
IscsiTargetAttributesEntry ::= SEQUENCE {
iscsiTgtLoginFailures Counter32,
iscsiTgtLastFailureTime TimeStamp,
iscsiTgtLastFailureType AutonomousType,
iscsiTgtLastIntrFailureName IscsiName,
iscsiTgtLastIntrFailureAddrType InetAddressType,
iscsiTgtLastIntrFailureAddr InetAddress,
iscsiTgtLastIntrFailurePort InetPortNumber
}
iscsiTgtLoginFailures OBJECT-TYPE
SYNTAX Counter32
UNITS "failed login attempts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object counts the number of times a login attempt to this
local target has failed.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
"RFC 7143, Section 11.13.5, Status-Class and Status-Detail"
::= { iscsiTargetAttributesEntry 1 }
Bakke & Venkatesen Standards Track [Page 40]
RFC 7147 iSCSI MIB April 2014
iscsiTgtLastFailureTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The timestamp of the most recent failure of a login attempt
to this target. A value of zero indicates that no such
failures have occurred since the last system boot."
::= { iscsiTargetAttributesEntry 2 }
iscsiTgtLastFailureType OBJECT-TYPE
SYNTAX AutonomousType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the most recent failure of a login attempt
to this target, represented as the OID of the counter
object in iscsiTargetLoginStatsTable for which the
relevant instance was incremented. If no such failures
have occurred since the last system boot, this attribute
will have the value 0.0. A value of 0.0 may also be used
to indicate a type that is not represented by any of
the counters in iscsiTargetLoginStatsTable."
::= { iscsiTargetAttributesEntry 3 }
iscsiTgtLastIntrFailureName OBJECT-TYPE
SYNTAX IscsiName
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The iSCSI name of the initiator that failed the last
login attempt. If no such failures have occurred since
the last system boot, this value is a zero-length string."
::= { iscsiTargetAttributesEntry 4 }
iscsiTgtLastIntrFailureAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Internet Network Address contained in the
corresponding instance of the iscsiTgtLastIntrFailureAddr.
The value 'dns' is not allowed. If no such failures have
occurred since the last system boot, this value is zero."
::= { iscsiTargetAttributesEntry 5 }
iscsiTgtLastIntrFailureAddr OBJECT-TYPE
SYNTAX InetAddress
Bakke & Venkatesen Standards Track [Page 41]
RFC 7147 iSCSI MIB April 2014
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An Internet Network Address, of the type specified by
the object iscsiTgtLastIntrFailureAddrType, giving the
host address of the initiator that failed the last login
attempt. If no such failures have occurred since the last
system boot, this value is a zero-length string."
::= { iscsiTargetAttributesEntry 6 }
iscsiTgtLastIntrFailurePort OBJECT-TYPE
SYNTAX InetPortNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transport protocol port number used by the initiator
that failed the last login attempt. If no such failures
have occurred since the last system boot, this value is a
zero-length string."
::= { iscsiTargetAttributesEntry 7 }
-- Target Login Stats Table
iscsiTargetLoginStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF IscsiTargetLoginStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of counters that keep a record of the results
of initiators' login attempts to this target."
::= { iscsiTarget 2 }
iscsiTargetLoginStatsEntry OBJECT-TYPE
SYNTAX IscsiTargetLoginStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (row) containing counters for each result of
a login attempt to this target."
AUGMENTS { iscsiTargetAttributesEntry }
::= { iscsiTargetLoginStatsTable 1 }
IscsiTargetLoginStatsEntry ::= SEQUENCE {
iscsiTgtLoginAccepts Counter32,
iscsiTgtLoginOtherFails Counter32,
iscsiTgtLoginRedirects Counter32,
iscsiTgtLoginAuthorizeFails Counter32,
iscsiTgtLoginAuthenticateFails Counter32,
Bakke & Venkatesen Standards Track [Page 42]
RFC 7147 iSCSI MIB April 2014
iscsiTgtLoginNegotiateFails Counter32
}
iscsiTgtLoginAccepts OBJECT-TYPE
SYNTAX Counter32
UNITS "successful logins"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of Login Response PDUs with status
0x0000, Accept Login, transmitted by this
target.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
"RFC 7143, Section 11.13.5, Status-Class and Status-Detail"
::= { iscsiTargetLoginStatsEntry 1 }
iscsiTgtLoginOtherFails OBJECT-TYPE
SYNTAX Counter32
UNITS "failed logins"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Login Response PDUs that were transmitted
by this target and that were not counted by any other
object in the row.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
"RFC 7143, Section 11.13.5, Status-Class and Status-Detail"
::= { iscsiTargetLoginStatsEntry 2 }
iscsiTgtLoginRedirects OBJECT-TYPE
SYNTAX Counter32
UNITS "redirected logins"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of Login Response PDUs with status class 0x01,
Redirection, transmitted by this target.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
"RFC 7143, Section 11.13.5, Status-Class and Status-Detail"
::= { iscsiTargetLoginStatsEntry 3 }
iscsiTgtLoginAuthorizeFails OBJECT-TYPE
Bakke & Venkatesen Standards Track [Page 43]
RFC 7147 iSCSI MIB April 2014
SYNTAX Counter32
UNITS "failed logins"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of Login Response PDUs with status 0x0202,
Forbidden Target, transmitted by this target.
If this counter is incremented, an iscsiTgtLoginFailure
notification should be generated.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
"RFC 7143, Section 11.13.5, Status-Class and Status-Detail"
::= { iscsiTargetLoginStatsEntry 4 }
iscsiTgtLoginAuthenticateFails OBJECT-TYPE
SYNTAX Counter32
UNITS "failed logins"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of Login Response PDUs with status 0x0201,
Authentication Failed, transmitted by this target.
If this counter is incremented, an iscsiTgtLoginFailure
notification should be generated.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
"RFC 7143, Section 11.13.5, Status-Class and Status-Detail"
::= { iscsiTargetLoginStatsEntry 5 }
iscsiTgtLoginNegotiateFails OBJECT-TYPE
SYNTAX Counter32
UNITS "failed logins"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times a target has effectively refused a
login because the parameter negotiation failed.
If this counter is incremented, an iscsiTgtLoginFailure
notification should be generated.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
::= { iscsiTargetLoginStatsEntry 6 }
Bakke & Venkatesen Standards Track [Page 44]
RFC 7147 iSCSI MIB April 2014
-- Target Logout Stats Table
iscsiTargetLogoutStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF IscsiTargetLogoutStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"When a target receives a Logout command, it responds
with a Logout Response that carries a status code.
This table contains counters for both normal and
abnormal Logout Requests received by this target."
::= { iscsiTarget 3 }
iscsiTargetLogoutStatsEntry OBJECT-TYPE
SYNTAX IscsiTargetLogoutStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (row) containing counters of Logout Response
PDUs that were received by this target."
AUGMENTS { iscsiTargetAttributesEntry }
::= { iscsiTargetLogoutStatsTable 1 }
IscsiTargetLogoutStatsEntry ::= SEQUENCE {
iscsiTgtLogoutNormals Counter32,
iscsiTgtLogoutOthers Counter32,
iscsiTgtLogoutCxnClosed Counter32,
iscsiTgtLogoutCxnRemoved Counter32
}
iscsiTgtLogoutNormals OBJECT-TYPE
SYNTAX Counter32
UNITS "normal logouts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of Logout Command PDUs received by this target,
with reason code 0 (closes the session).
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
"RFC 7143, Section 11.14.1, Reason Code"
::= { iscsiTargetLogoutStatsEntry 1 }
iscsiTgtLogoutOthers OBJECT-TYPE
SYNTAX Counter32
UNITS "abnormal logouts"
MAX-ACCESS read-only
Bakke & Venkatesen Standards Track [Page 45]
RFC 7147 iSCSI MIB April 2014
STATUS current
DESCRIPTION
"The count of Logout Command PDUs received by this target,
with any reason code other than 0.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
"RFC 7143, Section 11.14.1, Reason Code"
::= { iscsiTargetLogoutStatsEntry 2 }
iscsiTgtLogoutCxnClosed OBJECT-TYPE
SYNTAX Counter32
UNITS "abnormal logouts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of Logout Command PDUs received by this target,
with reason code 1 (closes the connection).
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
"RFC 7143, Section 11.14.1, Reason Code"
::= { iscsiTargetLogoutStatsEntry 3 }
iscsiTgtLogoutCxnRemoved OBJECT-TYPE
SYNTAX Counter32
UNITS "abnormal logouts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of Logout Command PDUs received by this target,
with reason code 2 (removes the connection).
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
"RFC 7143, Section 11.14.1, Reason Code"
::= { iscsiTargetLogoutStatsEntry 4 }
--**********************************************************************
iscsiTgtAuthorization OBJECT IDENTIFIER ::= { iscsiObjects 7 }
-- Target Authorization Attributes Table
iscsiTgtAuthAttributesTable OBJECT-TYPE
SYNTAX SEQUENCE OF IscsiTgtAuthAttributesEntry
MAX-ACCESS not-accessible
STATUS current
Bakke & Venkatesen Standards Track [Page 46]
RFC 7147 iSCSI MIB April 2014
DESCRIPTION
"A list of initiator identities that are authorized to
access each target node within each iSCSI instance
present on the local system."
::= { iscsiTgtAuthorization 1 }
iscsiTgtAuthAttributesEntry OBJECT-TYPE
SYNTAX IscsiTgtAuthAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (row) containing management information
applicable to a particular target node's authorized
initiator identity."
INDEX { iscsiInstIndex, iscsiNodeIndex, iscsiTgtAuthIndex }
::= { iscsiTgtAuthAttributesTable 1 }
IscsiTgtAuthAttributesEntry ::= SEQUENCE {
iscsiTgtAuthIndex Unsigned32,
iscsiTgtAuthRowStatus RowStatus,
iscsiTgtAuthIdentity RowPointer,
iscsiTgtAuthStorageType StorageType
}
iscsiTgtAuthIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer used to uniquely identify a particular
target's authorized initiator identity within an iSCSI
instance present on the local system. This index value must
not be modified or reused by an agent unless a reboot has
occurred. An agent should attempt to keep this value
persistent across reboots."
::= { iscsiTgtAuthAttributesEntry 1 }
iscsiTgtAuthRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This field allows entries to be dynamically added and
removed from this table via SNMP. When adding a row to
this table, all non-Index/RowStatus objects must be set.
When the value of this object is 'active', the values of
the other objects in this table cannot be changed.
Rows may be discarded using RowStatus."
Bakke & Venkatesen Standards Track [Page 47]
RFC 7147 iSCSI MIB April 2014
::= { iscsiTgtAuthAttributesEntry 2 }
iscsiTgtAuthIdentity OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A pointer to the corresponding user entry in the IPS-AUTH
MIB module that will be allowed to access this iSCSI target."
REFERENCE
"IPS-AUTH MIB, RFC 4545, Section 7.3, ipsAuthIdentity"
::= { iscsiTgtAuthAttributesEntry 3 }
iscsiTgtAuthStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The storage type for this row. Rows in this table that were
created through an external process (e.g., not created via
this MIB) may have a storage type of readOnly or permanent.
Conceptual rows having the value 'permanent' need not
allow write access to any columnar objects in the row."
DEFVAL { nonVolatile }
::= { iscsiTgtAuthAttributesEntry 4 }
--**********************************************************************
iscsiInitiator OBJECT IDENTIFIER ::= { iscsiObjects 8 }
-- Initiator Attributes Table
iscsiInitiatorAttributesTable OBJECT-TYPE
SYNTAX SEQUENCE OF IscsiInitiatorAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of iSCSI nodes that can take on an initiator
role, belonging to each iSCSI instance present on
the local system."
::= { iscsiInitiator 1 }
iscsiInitiatorAttributesEntry OBJECT-TYPE
SYNTAX IscsiInitiatorAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
Bakke & Venkatesen Standards Track [Page 48]
RFC 7147 iSCSI MIB April 2014
"An entry (row) containing management information
applicable to a particular iSCSI node that has
initiator capabilities."
INDEX { iscsiInstIndex, iscsiNodeIndex }
::= { iscsiInitiatorAttributesTable 1 }
IscsiInitiatorAttributesEntry ::= SEQUENCE {
iscsiIntrLoginFailures Counter32,
iscsiIntrLastFailureTime TimeStamp,
iscsiIntrLastFailureType AutonomousType,
iscsiIntrLastTgtFailureName IscsiName,
iscsiIntrLastTgtFailureAddrType InetAddressType,
iscsiIntrLastTgtFailureAddr InetAddress,
iscsiIntrLastTgtFailurePort InetPortNumber
}
iscsiIntrLoginFailures OBJECT-TYPE
SYNTAX Counter32
UNITS "failed logins"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object counts the number of times a login attempt from
this local initiator has failed.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
"RFC 7143, Section 11.13.5, Status-Class and Status-Detail"
::= { iscsiInitiatorAttributesEntry 1 }
iscsiIntrLastFailureTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The timestamp of the most recent failure of a login attempt
from this initiator. A value of zero indicates that no such
failures have occurred since the last system boot."
::= { iscsiInitiatorAttributesEntry 2 }
iscsiIntrLastFailureType OBJECT-TYPE
SYNTAX AutonomousType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the most recent failure of a login attempt
from this initiator, represented as the OID of the counter
object in iscsiInitiatorLoginStatsTable for which the
Bakke & Venkatesen Standards Track [Page 49]
RFC 7147 iSCSI MIB April 2014
relevant instance was incremented. If no such failures have
occurred since the last system boot, this attribute will
have the value 0.0. A value of 0.0 may also be used to
indicate a type that is not represented by any of
the counters in iscsiInitiatorLoginStatsTable."
::= { iscsiInitiatorAttributesEntry 3 }
iscsiIntrLastTgtFailureName OBJECT-TYPE
SYNTAX IscsiName
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A UTF-8 string giving the name of the target that failed
the last login attempt. If no such failures have occurred
since the last system boot, this value is a zero-length string."
::= { iscsiInitiatorAttributesEntry 4 }
iscsiIntrLastTgtFailureAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Internet Network Address contained in the
corresponding instance of the iscsiIntrLastTgtFailureAddr.
The value 'dns' is not allowed. If no such failures have
occurred since the last system boot, this value is zero."
::= { iscsiInitiatorAttributesEntry 5 }
iscsiIntrLastTgtFailureAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An Internet Network Address, of the type specified by the
object iscsiIntrLastTgtFailureAddrType, giving the host
address of the target that failed the last login attempt.
If no such failures have occurred since the last system boot,
this value is a zero-length string."
::= { iscsiInitiatorAttributesEntry 6 }
iscsiIntrLastTgtFailurePort OBJECT-TYPE
SYNTAX InetPortNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transport protocol port number used by the target
that failed the last login attempt.
If no such failures have occurred since the last system boot,
Bakke & Venkatesen Standards Track [Page 50]
RFC 7147 iSCSI MIB April 2014
this value is a zero-length string."
::= { iscsiInitiatorAttributesEntry 7 }
-- Initiator Login Stats Table
iscsiInitiatorLoginStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF IscsiInitiatorLoginStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of counters that keep track of the results of
this initiator's login attempts."
::= { iscsiInitiator 2 }
iscsiInitiatorLoginStatsEntry OBJECT-TYPE
SYNTAX IscsiInitiatorLoginStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (row) containing counters of each result
of this initiator's login attempts."
AUGMENTS { iscsiInitiatorAttributesEntry }
::= { iscsiInitiatorLoginStatsTable 1 }
IscsiInitiatorLoginStatsEntry ::= SEQUENCE {
iscsiIntrLoginAcceptRsps Counter32,
iscsiIntrLoginOtherFailRsps Counter32,
iscsiIntrLoginRedirectRsps Counter32,
iscsiIntrLoginAuthFailRsps Counter32,
iscsiIntrLoginAuthenticateFails Counter32,
iscsiIntrLoginNegotiateFails Counter32,
iscsiIntrLoginAuthorizeFails Counter32
}
iscsiIntrLoginAcceptRsps OBJECT-TYPE
SYNTAX Counter32
UNITS "successful logins"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of Login Response PDUs with status
0x0000, Accept Login, received by this initiator.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
"RFC 7143, Section 11.13.5, Status-Class and Status-Detail"
::= { iscsiInitiatorLoginStatsEntry 1 }
Bakke & Venkatesen Standards Track [Page 51]
RFC 7147 iSCSI MIB April 2014
iscsiIntrLoginOtherFailRsps OBJECT-TYPE
SYNTAX Counter32
UNITS "failed logins"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of Login Response PDUs received by this
initiator with any status code not counted in the
objects below.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
"RFC 7143, Section 11.13.5, Status-Class and Status-Detail"
::= { iscsiInitiatorLoginStatsEntry 2 }
iscsiIntrLoginRedirectRsps OBJECT-TYPE
SYNTAX Counter32
UNITS "failed logins"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of Login Response PDUs with status class 0x01,
Redirection, received by this initiator.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
"RFC 7143, Section 11.13.5, Status-Class and Status-Detail"
::= { iscsiInitiatorLoginStatsEntry 3 }
iscsiIntrLoginAuthFailRsps OBJECT-TYPE
SYNTAX Counter32
UNITS "failed logins"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of Login Response PDUs with status class 0x201,
Authentication Failed, received by this initiator.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
"RFC 7143, Section 11.13.5, Status-Class and Status-Detail"
::= { iscsiInitiatorLoginStatsEntry 4 }
iscsiIntrLoginAuthenticateFails OBJECT-TYPE
SYNTAX Counter32
UNITS "failed logins"
MAX-ACCESS read-only
STATUS current
Bakke & Venkatesen Standards Track [Page 52]
RFC 7147 iSCSI MIB April 2014
DESCRIPTION
"The number of times the initiator has aborted a
login because the target could not be authenticated.
No response is generated.
If this counter is incremented, an iscsiIntrLoginFailure
notification should be generated.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
"RFC 7143, Section 11.13.5, Status-Class and Status-Detail"
::= { iscsiInitiatorLoginStatsEntry 5 }
iscsiIntrLoginNegotiateFails OBJECT-TYPE
SYNTAX Counter32
UNITS "failed logins"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the initiator has aborted a
login because parameter negotiation with the target
failed.
No response is generated.
If this counter is incremented, an iscsiIntrLoginFailure
notification should be generated.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
"RFC 7143, Section 7.12, Negotiation Failures"
::= { iscsiInitiatorLoginStatsEntry 6 }
iscsiIntrLoginAuthorizeFails OBJECT-TYPE
SYNTAX Counter32
UNITS "failed logins"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of Login Response PDUs with status 0x0202,
Forbidden Target, received by this initiator.
If this counter is incremented, an iscsiIntrLoginFailure
notification should be generated.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
Bakke & Venkatesen Standards Track [Page 53]
RFC 7147 iSCSI MIB April 2014
"RFC 7143, Section 11.13.5, Status-Class and Status-Detail"
::= { iscsiInitiatorLoginStatsEntry 7 }
-- Initiator Logout Stats Table
iscsiInitiatorLogoutStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF IscsiInitiatorLogoutStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"When an initiator attempts to send a Logout command, the target
responds with a Logout Response that carries a status code.
This table contains a list of counters of Logout Response
PDUs of each status code that was received by each
initiator belonging to this iSCSI instance present on this
system."
::= { iscsiInitiator 3 }
iscsiInitiatorLogoutStatsEntry OBJECT-TYPE
SYNTAX IscsiInitiatorLogoutStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (row) containing counters of Logout Response
PDUs of each status code that was generated by this
initiator."
AUGMENTS { iscsiInitiatorAttributesEntry }
::= { iscsiInitiatorLogoutStatsTable 1 }
IscsiInitiatorLogoutStatsEntry ::= SEQUENCE {
iscsiIntrLogoutNormals Counter32,
iscsiIntrLogoutOthers Counter32
}
iscsiIntrLogoutNormals OBJECT-TYPE
SYNTAX Counter32
UNITS "normal logouts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of Logout Command PDUs generated by this initiator
with reason code 0 (closes the session).
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
"RFC 7143, Section 11.14.1, Reason Code"
::= { iscsiInitiatorLogoutStatsEntry 1 }
Bakke & Venkatesen Standards Track [Page 54]
RFC 7147 iSCSI MIB April 2014
iscsiIntrLogoutOthers OBJECT-TYPE
SYNTAX Counter32
UNITS "abnormal logouts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of Logout Command PDUs generated by this initiator
with any status code other than 0.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiNodeDiscontinuityTime."
REFERENCE
"RFC 7143, Section 11.14.1, Reason Code"
::= { iscsiInitiatorLogoutStatsEntry 2 }
--**********************************************************************
iscsiIntrAuthorization OBJECT IDENTIFIER ::= { iscsiObjects 9 }
-- Initiator Authorization Attributes Table
iscsiIntrAuthAttributesTable OBJECT-TYPE
SYNTAX SEQUENCE OF IscsiIntrAuthAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of target identities that each initiator
on the local system may access."
::= { iscsiIntrAuthorization 1 }
iscsiIntrAuthAttributesEntry OBJECT-TYPE
SYNTAX IscsiIntrAuthAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (row) containing management information applicable
to a particular initiator node's authorized target identity."
INDEX { iscsiInstIndex, iscsiNodeIndex, iscsiIntrAuthIndex }
::= { iscsiIntrAuthAttributesTable 1 }
IscsiIntrAuthAttributesEntry ::= SEQUENCE {
iscsiIntrAuthIndex Unsigned32,
iscsiIntrAuthRowStatus RowStatus,
iscsiIntrAuthIdentity RowPointer,
iscsiIntrAuthStorageType StorageType
}
iscsiIntrAuthIndex OBJECT-TYPE
Bakke & Venkatesen Standards Track [Page 55]
RFC 7147 iSCSI MIB April 2014
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer used to uniquely identify a
particular initiator node's authorized target
identity within an iSCSI instance present on the
local system. This index value must not be modified
or reused by an agent unless a reboot has occurred.
An agent should attempt to keep this value persistent
across reboots."
::= { iscsiIntrAuthAttributesEntry 1 }
iscsiIntrAuthRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This field allows entries to be dynamically added and
removed from this table via SNMP. When adding a row to
this table, all non-Index/RowStatus objects must be set.
When the value of this object is 'active', the values of
the other objects in this table cannot be changed.
Rows may be discarded using RowStatus."
::= { iscsiIntrAuthAttributesEntry 2 }
iscsiIntrAuthIdentity OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A pointer to the corresponding user entry in the IPS-AUTH
MIB module to which this initiator node should attempt to
establish an iSCSI session."
REFERENCE
"IPS-AUTH MIB, RFC 4545, Section 7.3, ipsAuthIdentity"
::= { iscsiIntrAuthAttributesEntry 3 }
iscsiIntrAuthStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The storage type for this row. Rows in this table that were
created through an external process (e.g., not created via
this MIB) may have a storage type of readOnly or permanent.
Conceptual rows having the value 'permanent' need not
Bakke & Venkatesen Standards Track [Page 56]
RFC 7147 iSCSI MIB April 2014
allow write access to any columnar objects in the row."
DEFVAL { nonVolatile }
::= { iscsiIntrAuthAttributesEntry 4 }
--**********************************************************************
iscsiSession OBJECT IDENTIFIER ::= { iscsiObjects 10 }
-- Session Attributes Table
iscsiSessionAttributesTable OBJECT-TYPE
SYNTAX SEQUENCE OF IscsiSessionAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of sessions belonging to each iSCSI instance
present on the system."
::= { iscsiSession 1 }
iscsiSessionAttributesEntry OBJECT-TYPE
SYNTAX IscsiSessionAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (row) containing management information applicable
to a particular session.
If this session is a discovery session that is not attached
to any particular node, the iscsiSsnNodeIndex will be zero.
Otherwise, the iscsiSsnNodeIndex will have the same value as
iscsiNodeIndex."
INDEX { iscsiInstIndex, iscsiSsnNodeIndex, iscsiSsnIndex }
::= { iscsiSessionAttributesTable 1 }
IscsiSessionAttributesEntry ::= SEQUENCE {
iscsiSsnNodeIndex Unsigned32,
iscsiSsnIndex Unsigned32,
iscsiSsnDirection INTEGER,
iscsiSsnInitiatorName IscsiName,
iscsiSsnTargetName IscsiName,
iscsiSsnTSIH Unsigned32,
iscsiSsnISID OCTET STRING,
iscsiSsnInitiatorAlias SnmpAdminString,
iscsiSsnTargetAlias SnmpAdminString,
iscsiSsnInitialR2T TruthValue,
iscsiSsnImmediateData TruthValue,
iscsiSsnType INTEGER,
iscsiSsnMaxOutstandingR2T Unsigned32,
Bakke & Venkatesen Standards Track [Page 57]
RFC 7147 iSCSI MIB April 2014
iscsiSsnFirstBurstLength Unsigned32,
iscsiSsnMaxBurstLength Unsigned32,
iscsiSsnConnectionNumber Gauge32,
iscsiSsnAuthIdentity RowPointer,
iscsiSsnDataSequenceInOrder TruthValue,
iscsiSsnDataPDUInOrder TruthValue,
iscsiSsnErrorRecoveryLevel Unsigned32,
iscsiSsnDiscontinuityTime TimeStamp,
iscsiSsnProtocolLevel Unsigned32,
iscsiSsnTaskReporting BITS
}
iscsiSsnNodeIndex OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer used to uniquely identify a
particular node within an iSCSI instance present
on the local system. For normal, non-discovery
sessions, this value will map to the iscsiNodeIndex.
For discovery sessions that do not have a node
associated, the value 0 (zero) is used."
::= { iscsiSessionAttributesEntry 1 }
iscsiSsnIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer used to uniquely identify a
particular session within an iSCSI instance present
on the local system. An agent should attempt to
not reuse index values unless a reboot has occurred.
iSCSI sessions are destroyed during a reboot; rows
in this table are not persistent across reboots."
::= { iscsiSessionAttributesEntry 2 }
iscsiSsnDirection OBJECT-TYPE
SYNTAX INTEGER {
inboundSession(1),
outboundSession(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Direction of iSCSI session:
inboundSession - session is established from an external
Bakke & Venkatesen Standards Track [Page 58]
RFC 7147 iSCSI MIB April 2014
initiator to a target within this iSCSI
instance.
outboundSession - session is established from an initiator
within this iSCSI instance to an external
target."
::= { iscsiSessionAttributesEntry 3 }
iscsiSsnInitiatorName OBJECT-TYPE
SYNTAX IscsiName
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If iscsiSsnDirection is Inbound, this object is a
UTF-8 string that will contain the name of the remote
initiator. If this session is a discovery session that
does not specify a particular initiator, this object
will contain a zero-length string.
If iscsiSsnDirection is Outbound, this object will
contain a zero-length string."
::= { iscsiSessionAttributesEntry 4 }
iscsiSsnTargetName OBJECT-TYPE
SYNTAX IscsiName
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If iscsiSsnDirection is Outbound, this object is a
UTF-8 string that will contain the name of the remote
target. If this session is a discovery session that
does not specify a particular target, this object will
contain a zero-length string.
If iscsiSsnDirection is Inbound, this object will
contain a zero-length string."
::= { iscsiSessionAttributesEntry 5 }
iscsiSsnTSIH OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The target-defined identification handle for this session."
REFERENCE
"RFC 7143, Section 11.12.6, TSIH"
::= { iscsiSessionAttributesEntry 6 }
iscsiSsnISID OBJECT-TYPE
Bakke & Venkatesen Standards Track [Page 59]
RFC 7147 iSCSI MIB April 2014
SYNTAX OCTET STRING (SIZE(6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The initiator-defined portion of the iSCSI Session ID."
REFERENCE
"RFC 7143, Section 11.12.5, ISID"
::= { iscsiSessionAttributesEntry 7 }
iscsiSsnInitiatorAlias OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A UTF-8 string that gives the alias communicated by the
initiator end of the session during the login phase.
If no alias exists, the value is a zero-length string."
REFERENCE
"RFC 7143, Section 13.7, InitiatorAlias"
::= { iscsiSessionAttributesEntry 8 }
iscsiSsnTargetAlias OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A UTF-8 string that gives the alias communicated by the
target end of the session during the login phase.
If no alias exists, the value is a zero-length string."
REFERENCE
"RFC 7143, Section 13.6, TargetAlias"
::= { iscsiSessionAttributesEntry 9 }
iscsiSsnInitialR2T OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If set to true, indicates that the initiator must wait
for an R2T before sending to the target. If set to false,
the initiator may send data immediately, within limits set
by iscsiSsnFirstBurstLength and the expected data transfer
length of the request."
REFERENCE
"RFC 7143, Section 13.10, InitialR2T"
::= { iscsiSessionAttributesEntry 10 }
Bakke & Venkatesen Standards Track [Page 60]
RFC 7147 iSCSI MIB April 2014
iscsiSsnImmediateData OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the initiator and target have agreed to
support immediate data on this session."
REFERENCE
"RFC 7143, Section 13.11, ImmediateData"
::= { iscsiSessionAttributesEntry 11 }
iscsiSsnType OBJECT-TYPE
SYNTAX INTEGER {
normalSession(1),
discoverySession(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of iSCSI session:
normalSession - session is a normal iSCSI session
discoverySession - session is being used only for discovery."
REFERENCE
"RFC 7143, Section 13.21, SessionType"
::= { iscsiSessionAttributesEntry 12 }
iscsiSsnMaxOutstandingR2T OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
UNITS "R2Ts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of outstanding requests-to-transmit
(R2Ts) per iSCSI task within this session."
REFERENCE
"RFC 7143, Section 13.17, MaxOutstandingR2T"
::= { iscsiSessionAttributesEntry 13 }
iscsiSsnFirstBurstLength OBJECT-TYPE
SYNTAX Unsigned32 (512..16777215)
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum length supported for unsolicited data sent
within this session."
REFERENCE
Bakke & Venkatesen Standards Track [Page 61]
RFC 7147 iSCSI MIB April 2014
"RFC 7143, Section 13.14, FirstBurstLength"
::= { iscsiSessionAttributesEntry 14 }
iscsiSsnMaxBurstLength OBJECT-TYPE
SYNTAX Unsigned32 (512..16777215)
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of bytes that can be sent within
a single sequence of Data-In or Data-Out PDUs."
REFERENCE
"RFC 7143, Section 13.13, MaxBurstLength"
::= { iscsiSessionAttributesEntry 15 }
iscsiSsnConnectionNumber OBJECT-TYPE
SYNTAX Gauge32 (1..65535)
UNITS "connections"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transport protocol connections that currently
belong to this session."
::= { iscsiSessionAttributesEntry 16 }
iscsiSsnAuthIdentity OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains a pointer to a row in the
IPS-AUTH MIB module that identifies the authentication
identity being used on this session, as communicated
during the login phase."
REFERENCE
"IPS-AUTH MIB, RFC 4545, Section 7.3, ipsAuthIdentity"
::= { iscsiSessionAttributesEntry 17 }
iscsiSsnDataSequenceInOrder OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"False indicates that iSCSI data PDU sequences may
be transferred in any order. True indicates that
data PDU sequences must be transferred using
continuously increasing offsets, except during
error recovery."
Bakke & Venkatesen Standards Track [Page 62]
RFC 7147 iSCSI MIB April 2014
REFERENCE
"RFC 7143, Section 13.19, DataSequenceInOrder"
::= { iscsiSessionAttributesEntry 18 }
iscsiSsnDataPDUInOrder OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"False indicates that iSCSI data PDUs within sequences
may be in any order. True indicates that data PDUs
within sequences must be at continuously increasing
addresses, with no gaps or overlay between PDUs.
Default is true."
REFERENCE
"RFC 7143, Section 13.18, DataPDUInOrder"
::= { iscsiSessionAttributesEntry 19 }
iscsiSsnErrorRecoveryLevel OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The level of error recovery negotiated between
the initiator and the target. Higher numbers
represent more detailed recovery schemes."
REFERENCE
"RFC 7143, Section 13.20, ErrorRecoveryLevel"
::= { iscsiSessionAttributesEntry 20 }
iscsiSsnDiscontinuityTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of SysUpTime on the most recent occasion
at which any one or more of this session's counters
suffered a discontinuity.
When a session is established, and this object is
created, it is initialized to the current value
of SysUpTime."
::= { iscsiSessionAttributesEntry 21 }
iscsiSsnProtocolLevel OBJECT-TYPE
SYNTAX Unsigned32 (0..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
Bakke & Venkatesen Standards Track [Page 63]
RFC 7147 iSCSI MIB April 2014
"The iSCSI protocol level negotiated for this session."
REFERENCE
"RFC 7144, Section 7.1.1, iSCSIProtocolLevel"
DEFVAL { 1 }
::= { iscsiSessionAttributesEntry 22 }
iscsiSsnTaskReporting OBJECT-TYPE
SYNTAX BITS {
taskReportingRfc3720(0),
taskReportingResponseFence(1),
taskReportingFastAbort(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This key is used to negotiate the task completion reporting
semantics from the SCSI target.
Default value is taskReportingRfc3720."
REFERENCE
"RFC 7143, Section 13.23, TaskReporting"
::= { iscsiSessionAttributesEntry 23 }
-- Session Stats Table
iscsiSessionStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF IscsiSessionStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of general iSCSI traffic counters for each of the
sessions present on the system."
::= { iscsiSession 2 }
iscsiSessionStatsEntry OBJECT-TYPE
SYNTAX IscsiSessionStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (row) containing general iSCSI traffic counters
for a particular session."
AUGMENTS { iscsiSessionAttributesEntry }
::= { iscsiSessionStatsTable 1 }
IscsiSessionStatsEntry ::= SEQUENCE {
iscsiSsnCmdPDUs Counter32,
Bakke & Venkatesen Standards Track [Page 64]
RFC 7147 iSCSI MIB April 2014
iscsiSsnRspPDUs Counter32,
iscsiSsnTxDataOctets Counter64,
iscsiSsnRxDataOctets Counter64,
iscsiSsnLCTxDataOctets Counter32,
iscsiSsnLCRxDataOctets Counter32,
iscsiSsnNopReceivedPDUs Counter32,
iscsiSsnNopSentPDUs Counter32
}
iscsiSsnCmdPDUs OBJECT-TYPE
SYNTAX Counter32
UNITS "PDUs"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of Command PDUs transferred on this session.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiSsnDiscontinuityTime."
::= { iscsiSessionStatsEntry 1 }
iscsiSsnRspPDUs OBJECT-TYPE
SYNTAX Counter32
UNITS "PDUs"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of Response PDUs transferred on this session.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiSsnDiscontinuityTime."
::= { iscsiSessionStatsEntry 2 }
iscsiSsnTxDataOctets OBJECT-TYPE
SYNTAX Counter64
UNITS "octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of data octets that were transmitted by
the local iSCSI node on this session.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiSsnDiscontinuityTime."
::= { iscsiSessionStatsEntry 3 }
iscsiSsnRxDataOctets OBJECT-TYPE
SYNTAX Counter64
UNITS "octets"
MAX-ACCESS read-only
STATUS current
Bakke & Venkatesen Standards Track [Page 65]
RFC 7147 iSCSI MIB April 2014
DESCRIPTION
"The count of data octets that were received by
the local iSCSI node on this session.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiSsnDiscontinuityTime."
::= { iscsiSessionStatsEntry 4 }
iscsiSsnLCTxDataOctets OBJECT-TYPE
SYNTAX Counter32
UNITS "octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Low-Capacity shadow object of iscsiSsnTxDataOctets
for those systems that are accessible via SNMPv1 only.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiSsnDiscontinuityTime."
::= { iscsiSessionStatsEntry 5 }
iscsiSsnLCRxDataOctets OBJECT-TYPE
SYNTAX Counter32
UNITS "octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Low-Capacity shadow object of iscsiSsnRxDataOctets
for those systems which are accessible via SNMPv1 only.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiSsnDiscontinuityTime."
::= { iscsiSessionStatsEntry 6 }
iscsiSsnNopReceivedPDUs OBJECT-TYPE
SYNTAX Counter32
UNITS "PDUs"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of NOP-In or NOP-Out PDUs received on this session.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiSsnDiscontinuityTime."
::= { iscsiSessionStatsEntry 7 }
iscsiSsnNopSentPDUs OBJECT-TYPE
SYNTAX Counter32
UNITS "PDUs"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
Bakke & Venkatesen Standards Track [Page 66]
RFC 7147 iSCSI MIB April 2014
"The count of NOP-In or NOP-Out PDUs sent on this session.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiSsnDiscontinuityTime."
::= { iscsiSessionStatsEntry 8 }
-- Session Connection Error Stats Table
iscsiSessionCxnErrorStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF IscsiSessionCxnErrorStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of error counters for each of the sessions
present on this system."
::= { iscsiSession 3 }
iscsiSessionCxnErrorStatsEntry OBJECT-TYPE
SYNTAX IscsiSessionCxnErrorStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (row) containing error counters for
a particular session."
AUGMENTS { iscsiSessionAttributesEntry }
::= { iscsiSessionCxnErrorStatsTable 1 }
IscsiSessionCxnErrorStatsEntry ::= SEQUENCE {
iscsiSsnCxnDigestErrors Counter32,
iscsiSsnCxnTimeoutErrors Counter32
}
iscsiSsnCxnDigestErrors OBJECT-TYPE
SYNTAX Counter32
UNITS "PDUs"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of PDUs that were received on the session and
contained header or data digest errors.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiSsnDiscontinuityTime.
This counter is most likely provided when the error-recovery
level is 1 or 2"
REFERENCE
"RFC 7143, Section 7.8, Digest Errors"
::= { iscsiSessionCxnErrorStatsEntry 1 }
iscsiSsnCxnTimeoutErrors OBJECT-TYPE
Bakke & Venkatesen Standards Track [Page 67]
RFC 7147 iSCSI MIB April 2014
SYNTAX Counter32
UNITS "connections"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of connections within this session
that have been terminated due to timeout.
If this counter has suffered a discontinuity, the time of the
last discontinuity is indicated in iscsiSsnDiscontinuityTime.
This counter is most likely provided when the error-recovery
level is 2"
REFERENCE
"RFC 7143, Section 7.5, Connection Timeout Management"
::= { iscsiSessionCxnErrorStatsEntry 2 }
--**********************************************************************
iscsiConnection OBJECT IDENTIFIER ::= { iscsiObjects 11 }
-- Connection Attributes Table
iscsiConnectionAttributesTable OBJECT-TYPE
SYNTAX SEQUENCE OF IscsiConnectionAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of connections belonging to each iSCSI instance
present on the system."
::= { iscsiConnection 1 }
iscsiConnectionAttributesEntry OBJECT-TYPE
SYNTAX IscsiConnectionAttributesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (row) containing management information applicable
to a particular connection."
INDEX { iscsiInstIndex, iscsiSsnNodeIndex, iscsiSsnIndex,
iscsiCxnIndex }
::= { iscsiConnectionAttributesTable 1 }
IscsiConnectionAttributesEntry ::= SEQUENCE {
iscsiCxnIndex Unsigned32,
iscsiCxnCid Unsigned32,
iscsiCxnState INTEGER,
iscsiCxnAddrType InetAddressType,
iscsiCxnLocalAddr InetAddress,
iscsiCxnProtocol IscsiTransportProtocol,
Bakke & Venkatesen Standards Track [Page 68]
RFC 7147 iSCSI MIB April 2014
iscsiCxnLocalPort InetPortNumber,
iscsiCxnRemoteAddr InetAddress,
iscsiCxnRemotePort InetPortNumber,
iscsiCxnMaxRecvDataSegLength Unsigned32,
iscsiCxnMaxXmitDataSegLength Unsigned32,
iscsiCxnHeaderIntegrity IscsiDigestMethod,
iscsiCxnDataIntegrity IscsiDigestMethod,
iscsiCxnRecvMarker TruthValue,
iscsiCxnSendMarker TruthValue,
iscsiCxnVersionActive Unsigned32
}
iscsiCxnIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer used to uniquely identify a
particular connection of a particular session within
an iSCSI instance present on the local system. An
agent should attempt to not reuse index values unless
a reboot has occurred. iSCSI connections are destroyed
during a reboot; rows in this table are not persistent
across reboots."
::= { iscsiConnectionAttributesEntry 1 }
iscsiCxnCid OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The iSCSI Connection ID for this connection."
::= { iscsiConnectionAttributesEntry 2 }
iscsiCxnState OBJECT-TYPE
SYNTAX INTEGER {
login(1),
full(2),
logout(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of this connection, from an iSCSI negotiation
point of view. Here are the states:
login - The transport protocol connection has been established,
but a valid iSCSI login response with the final bit set
Bakke & Venkatesen Standards Track [Page 69]
RFC 7147 iSCSI MIB April 2014
has not been sent or received.
full - A valid iSCSI login response with the final bit set
has been sent or received.
logout - A valid iSCSI logout command has been sent or
received, but the transport protocol connection has
not yet been closed."
::= { iscsiConnectionAttributesEntry 3 }
iscsiCxnAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of Internet Network Addresses contained in the
corresponding instances of iscsiCxnLocalAddr and
iscsiCxnRemoteAddr.
The value 'dns' is not allowed."
::= { iscsiConnectionAttributesEntry 4 }
iscsiCxnLocalAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The local Internet Network Address, of the type specified
by iscsiCxnAddrType, used by this connection."
::= { iscsiConnectionAttributesEntry 5 }
iscsiCxnProtocol OBJECT-TYPE
SYNTAX IscsiTransportProtocol
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transport protocol over which this connection is
running."
::= { iscsiConnectionAttributesEntry 6 }
iscsiCxnLocalPort OBJECT-TYPE
SYNTAX InetPortNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The local transport protocol port used by this connection.
This object cannot have the value zero, since it represents
an established connection."
::= { iscsiConnectionAttributesEntry 7 }
iscsiCxnRemoteAddr OBJECT-TYPE
Bakke & Venkatesen Standards Track [Page 70]
RFC 7147 iSCSI MIB April 2014
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The remote Internet Network Address, of the type specified
by iscsiCxnAddrType, used by this connection."
::= { iscsiConnectionAttributesEntry 8 }
iscsiCxnRemotePort OBJECT-TYPE
SYNTAX InetPortNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The remote transport protocol port used by this connection.
This object cannot have the value zero, since it represents
an established connection."
::= { iscsiConnectionAttributesEntry 9 }
iscsiCxnMaxRecvDataSegLength OBJECT-TYPE
SYNTAX Unsigned32 (512..16777215)
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum data payload size supported for command
or data PDUs able to be received on this connection."
REFERENCE
"RFC 7143, Section 13.12, MaxRecvDataSegmentLength"
::= { iscsiConnectionAttributesEntry 10 }
iscsiCxnMaxXmitDataSegLength OBJECT-TYPE
SYNTAX Unsigned32 (512..16777215)
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum data payload size supported for command
or data PDUs to be sent on this connection."
REFERENCE
"RFC 7143, Section 13.12, MaxRecvDataSegmentLength"
::= { iscsiConnectionAttributesEntry 11 }
iscsiCxnHeaderIntegrity OBJECT-TYPE
SYNTAX IscsiDigestMethod
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the iSCSI header
Bakke & Venkatesen Standards Track [Page 71]
RFC 7147 iSCSI MIB April 2014
digest scheme in use within this connection."
::= { iscsiConnectionAttributesEntry 12 }
iscsiCxnDataIntegrity OBJECT-TYPE
SYNTAX IscsiDigestMethod
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the iSCSI data
digest scheme in use within this connection."
::= { iscsiConnectionAttributesEntry 13 }
iscsiCxnRecvMarker OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object indicates whether or not this connection
is receiving markers in its incoming data stream."
REFERENCE
"RFC 7143, Section 13.25, Obsoleted Keys."
::= { iscsiConnectionAttributesEntry 14 }
iscsiCxnSendMarker OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object indicates whether or not this connection
is inserting markers in its outgoing data stream."
REFERENCE
"RFC 7143, Section 13.25, Obsoleted Keys."
::= { iscsiConnectionAttributesEntry 15 }
iscsiCxnVersionActive OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active version number of the iSCSI specification negotiated
on this connection."
REFERENCE
"RFC 7143, Section 11.12, Login Request"
::= { iscsiConnectionAttributesEntry 16 }
--**********************************************************************
-- Notifications
Bakke & Venkatesen Standards Track [Page 72]
RFC 7147 iSCSI MIB April 2014
iscsiTgtLoginFailure NOTIFICATION-TYPE
OBJECTS {
iscsiTgtLoginFailures,
iscsiTgtLastFailureType,
iscsiTgtLastIntrFailureName,
iscsiTgtLastIntrFailureAddrType,
iscsiTgtLastIntrFailureAddr,
iscsiTgtLastIntrFailurePort
}
STATUS current
DESCRIPTION
"Sent when a login is failed by a target.
To avoid sending an excessive number of notifications due
to multiple errors counted, an SNMP agent implementing this
notification SHOULD NOT send more than 3 notifications of
this type in any 10-second time period."
::= { iscsiNotifications 1 }
iscsiIntrLoginFailure NOTIFICATION-TYPE
OBJECTS {
iscsiIntrLoginFailures,
iscsiIntrLastFailureType,
iscsiIntrLastTgtFailureName,
iscsiIntrLastTgtFailureAddrType,
iscsiIntrLastTgtFailureAddr,
iscsiIntrLastTgtFailurePort
}
STATUS current
DESCRIPTION
"Sent when a login is failed by an initiator.
To avoid sending an excessive number of notifications due
to multiple errors counted, an SNMP agent implementing this
notification SHOULD NOT send more than 3 notifications of
this type in any 10-second time period."
::= { iscsiNotifications 2 }
iscsiInstSessionFailure NOTIFICATION-TYPE
OBJECTS {
iscsiInstSsnFailures,
iscsiInstLastSsnFailureType,
iscsiInstLastSsnRmtNodeName
}
STATUS current
DESCRIPTION
"Sent when an active session is failed by either the initiator
or the target.
Bakke & Venkatesen Standards Track [Page 73]
RFC 7147 iSCSI MIB April 2014
To avoid sending an excessive number of notifications due
to multiple errors counted, an SNMP agent implementing this
notification SHOULD NOT send more than 3 notifications of
this type in any 10-second time period."
::= { iscsiNotifications 3 }
--**********************************************************************
-- Conformance Statements
iscsiCompliances OBJECT IDENTIFIER ::= { iscsiConformance 1 }
iscsiGroups OBJECT IDENTIFIER ::= { iscsiConformance 2 }
iscsiInstanceAttributesGroup OBJECT-GROUP
OBJECTS {
iscsiInstDescr,
iscsiInstVersionMin,
iscsiInstVersionMax,
iscsiInstVendorID,
iscsiInstVendorVersion,
iscsiInstPortalNumber,
iscsiInstNodeNumber,
iscsiInstSessionNumber,
iscsiInstSsnFailures,
iscsiInstLastSsnFailureType,
iscsiInstLastSsnRmtNodeName,
iscsiInstDiscontinuityTime,
iscsiInstXNodeArchitecture
}
STATUS current
DESCRIPTION
"A collection of objects providing information about iSCSI
instances."
::= { iscsiGroups 1 }
iscsiInstanceSsnErrorStatsGroup OBJECT-GROUP
OBJECTS {
iscsiInstSsnDigestErrors,
iscsiInstSsnCxnTimeoutErrors,
iscsiInstSsnFormatErrors
}
STATUS current
DESCRIPTION
"A collection of objects providing information about
errors that have caused a session failure for an
iSCSI instance."
::= { iscsiGroups 2 }
Bakke & Venkatesen Standards Track [Page 74]
RFC 7147 iSCSI MIB April 2014
iscsiPortalAttributesGroup OBJECT-GROUP
OBJECTS {
iscsiPortalRowStatus,
iscsiPortalStorageType,
iscsiPortalRoles,
iscsiPortalAddrType,
iscsiPortalAddr,
iscsiPortalProtocol,
iscsiPortalMaxRecvDataSegLength,
iscsiPortalPrimaryHdrDigest,
iscsiPortalPrimaryDataDigest,
iscsiPortalSecondaryHdrDigest,
iscsiPortalSecondaryDataDigest,
iscsiPortalRecvMarker
}
STATUS deprecated
DESCRIPTION
"A collection of objects providing information about
the transport protocol endpoints of the local targets.
This object group is deprecated because the marker key
is obsolete."
REFERENCE
"RFC 7143, Section 13.25, Obsoleted Keys."
::= { iscsiGroups 3 }
iscsiTgtPortalAttributesGroup OBJECT-GROUP
OBJECTS {
iscsiTgtPortalPort,
iscsiTgtPortalTag
}
STATUS current
DESCRIPTION
"A collection of objects providing information about
the transport protocol endpoints of the local targets."
::= { iscsiGroups 4 }
iscsiIntrPortalAttributesGroup OBJECT-GROUP
OBJECTS {
iscsiIntrPortalTag
}
STATUS current
DESCRIPTION
"An object providing information about
the portal tags used by the local initiators."
::= { iscsiGroups 5 }
iscsiNodeAttributesGroup OBJECT-GROUP
OBJECTS {
Bakke & Venkatesen Standards Track [Page 75]
RFC 7147 iSCSI MIB April 2014
iscsiNodeName,
iscsiNodeAlias,
iscsiNodeRoles,
iscsiNodeTransportType,
iscsiNodeInitialR2T,
iscsiNodeImmediateData,
iscsiNodeMaxOutstandingR2T,
iscsiNodeFirstBurstLength,
iscsiNodeMaxBurstLength,
iscsiNodeMaxConnections,
iscsiNodeDataSequenceInOrder,
iscsiNodeDataPDUInOrder,
iscsiNodeDefaultTime2Wait,
iscsiNodeDefaultTime2Retain,
iscsiNodeErrorRecoveryLevel,
iscsiNodeDiscontinuityTime,
iscsiNodeStorageType
}
STATUS current
DESCRIPTION
"A collection of objects providing information about all
local targets."
::= { iscsiGroups 6 }
iscsiTargetAttributesGroup OBJECT-GROUP
OBJECTS {
iscsiTgtLoginFailures,
iscsiTgtLastFailureTime,
iscsiTgtLastFailureType,
iscsiTgtLastIntrFailureName,
iscsiTgtLastIntrFailureAddrType,
iscsiTgtLastIntrFailureAddr
}
STATUS current
DESCRIPTION
"A collection of objects providing information about all
local targets."
::= { iscsiGroups 7 }
iscsiTargetLoginStatsGroup OBJECT-GROUP
OBJECTS {
iscsiTgtLoginAccepts,
iscsiTgtLoginOtherFails,
iscsiTgtLoginRedirects,
iscsiTgtLoginAuthorizeFails,
iscsiTgtLoginAuthenticateFails,
iscsiTgtLoginNegotiateFails
}
Bakke & Venkatesen Standards Track [Page 76]
RFC 7147 iSCSI MIB April 2014
STATUS current
DESCRIPTION
"A collection of objects providing information about all
login attempts by remote initiators to local targets."
::= { iscsiGroups 8 }
iscsiTargetLogoutStatsGroup OBJECT-GROUP
OBJECTS {
iscsiTgtLogoutNormals,
iscsiTgtLogoutOthers
}
STATUS current
DESCRIPTION
"A collection of objects providing information about all
logout events between remote initiators and local targets."
::= { iscsiGroups 9 }
iscsiTargetAuthGroup OBJECT-GROUP
OBJECTS {
iscsiTgtAuthRowStatus,
iscsiTgtAuthStorageType,
iscsiTgtAuthIdentity
}
STATUS current
DESCRIPTION
"A collection of objects providing information about all
remote initiators that are authorized to connect to local
targets."
::= { iscsiGroups 10 }
iscsiInitiatorAttributesGroup OBJECT-GROUP
OBJECTS {
iscsiIntrLoginFailures,
iscsiIntrLastFailureTime,
iscsiIntrLastFailureType,
iscsiIntrLastTgtFailureName,
iscsiIntrLastTgtFailureAddrType,
iscsiIntrLastTgtFailureAddr
}
STATUS current
DESCRIPTION
"A collection of objects providing information about
all local initiators."
::= { iscsiGroups 11 }
iscsiInitiatorLoginStatsGroup OBJECT-GROUP
OBJECTS {
iscsiIntrLoginAcceptRsps,
Bakke & Venkatesen Standards Track [Page 77]
RFC 7147 iSCSI MIB April 2014
iscsiIntrLoginOtherFailRsps,
iscsiIntrLoginRedirectRsps,
iscsiIntrLoginAuthFailRsps,
iscsiIntrLoginAuthenticateFails,
iscsiIntrLoginNegotiateFails,
iscsiIntrLoginAuthorizeFails
}
STATUS current
DESCRIPTION
"A collection of objects providing information about all
login attempts by local initiators to remote targets."
::= { iscsiGroups 12 }
iscsiInitiatorLogoutStatsGroup OBJECT-GROUP
OBJECTS {
iscsiIntrLogoutNormals,
iscsiIntrLogoutOthers
}
STATUS current
DESCRIPTION
"A collection of objects providing information about all
logout events between local initiators and remote targets."
::= { iscsiGroups 13 }
iscsiInitiatorAuthGroup OBJECT-GROUP
OBJECTS {
iscsiIntrAuthRowStatus,
iscsiIntrAuthStorageType,
iscsiIntrAuthIdentity
}
STATUS current
DESCRIPTION
"A collection of objects providing information about all
remote targets that are initiators of the local system
that they are authorized to access."
::= { iscsiGroups 14 }
iscsiSessionAttributesGroup OBJECT-GROUP
OBJECTS {
iscsiSsnDirection,
iscsiSsnInitiatorName,
iscsiSsnTargetName,
iscsiSsnTSIH,
iscsiSsnISID,
iscsiSsnInitiatorAlias,
iscsiSsnTargetAlias,
iscsiSsnInitialR2T,
iscsiSsnImmediateData,
Bakke & Venkatesen Standards Track [Page 78]
RFC 7147 iSCSI MIB April 2014
iscsiSsnType,
iscsiSsnMaxOutstandingR2T,
iscsiSsnFirstBurstLength,
iscsiSsnMaxBurstLength,
iscsiSsnConnectionNumber,
iscsiSsnAuthIdentity,
iscsiSsnDataSequenceInOrder,
iscsiSsnDataPDUInOrder,
iscsiSsnErrorRecoveryLevel,
iscsiSsnDiscontinuityTime,
iscsiSsnProtocolLevel,
iscsiSsnTaskReporting
}
STATUS current
DESCRIPTION
"A collection of objects providing information applicable to
all sessions."
::= { iscsiGroups 15 }
iscsiSessionPDUStatsGroup OBJECT-GROUP
OBJECTS {
iscsiSsnCmdPDUs,
iscsiSsnRspPDUs
}
STATUS current
DESCRIPTION
"A collection of objects providing information about PDU
traffic for each session."
::= { iscsiGroups 16 }
iscsiSessionOctetStatsGroup OBJECT-GROUP
OBJECTS {
iscsiSsnTxDataOctets,
iscsiSsnRxDataOctets
}
STATUS current
DESCRIPTION
"A collection of objects providing information about octet
traffic for each session using a Counter64 data type."
::= { iscsiGroups 17 }
iscsiSessionLCOctetStatsGroup OBJECT-GROUP
OBJECTS {
iscsiSsnLCTxDataOctets,
iscsiSsnLCRxDataOctets
}
STATUS current
DESCRIPTION
Bakke & Venkatesen Standards Track [Page 79]
RFC 7147 iSCSI MIB April 2014
"A collection of objects providing information about octet
traffic for each session using a Counter32 data type."
::= { iscsiGroups 18 }
iscsiSessionCxnErrorStatsGroup OBJECT-GROUP
OBJECTS {
iscsiSsnCxnDigestErrors,
iscsiSsnCxnTimeoutErrors
}
STATUS current
DESCRIPTION
"A collection of objects providing information about connection
errors for all sessions."
::= { iscsiGroups 19 }
iscsiConnectionAttributesGroup OBJECT-GROUP
OBJECTS {
iscsiCxnCid,
iscsiCxnState,
iscsiCxnProtocol,
iscsiCxnAddrType,
iscsiCxnLocalAddr,
iscsiCxnLocalPort,
iscsiCxnRemoteAddr,
iscsiCxnRemotePort,
iscsiCxnMaxRecvDataSegLength,
iscsiCxnMaxXmitDataSegLength,
iscsiCxnHeaderIntegrity,
iscsiCxnDataIntegrity,
iscsiCxnRecvMarker,
iscsiCxnSendMarker,
iscsiCxnVersionActive
}
STATUS deprecated
DESCRIPTION
"A collection of objects providing information about all
connections used by all sessions.
This object group is deprecated because the marker key
is obsolete."
REFERENCE
"RFC 7143, Section 13.25, Obsoleted Keys."
::= { iscsiGroups 20 }
iscsiTgtLgnNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS {
iscsiTgtLoginFailure
}
STATUS current
Bakke & Venkatesen Standards Track [Page 80]
RFC 7147 iSCSI MIB April 2014
DESCRIPTION
"A collection of notifications that indicate a login
failure from a remote initiator to a local target."
::= { iscsiGroups 21 }
iscsiIntrLgnNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS {
iscsiIntrLoginFailure
}
STATUS current
DESCRIPTION
"A collection of notifications that indicate a login
failure from a local initiator to a remote target."
::= { iscsiGroups 22 }
iscsiSsnFlrNotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS {
iscsiInstSessionFailure
}
STATUS current
DESCRIPTION
"A collection of notifications that indicate session
failures occurring after login."
::= { iscsiGroups 23 }
iscsiPortalAttributesGroupV2 OBJECT-GROUP
OBJECTS {
iscsiPortalRowStatus,
iscsiPortalStorageType,
iscsiPortalRoles,
iscsiPortalAddrType,
iscsiPortalAddr,
iscsiPortalProtocol,
iscsiPortalMaxRecvDataSegLength,
iscsiPortalPrimaryHdrDigest,
iscsiPortalPrimaryDataDigest,
iscsiPortalSecondaryHdrDigest,
iscsiPortalSecondaryDataDigest
}
STATUS current
DESCRIPTION
"A collection of objects providing information about
the transport protocol endpoints of the local targets."
::= { iscsiGroups 24 }
iscsiConnectionAttributesGroupV2 OBJECT-GROUP
OBJECTS {
iscsiCxnCid,
Bakke & Venkatesen Standards Track [Page 81]
RFC 7147 iSCSI MIB April 2014
iscsiCxnState,
iscsiCxnProtocol,
iscsiCxnAddrType,
iscsiCxnLocalAddr,
iscsiCxnLocalPort,
iscsiCxnRemoteAddr,
iscsiCxnRemotePort,
iscsiCxnMaxRecvDataSegLength,
iscsiCxnMaxXmitDataSegLength,
iscsiCxnHeaderIntegrity,
iscsiCxnDataIntegrity,
iscsiCxnVersionActive
}
STATUS current
DESCRIPTION
"A collection of objects providing information about all
connections used by all sessions."
::= { iscsiGroups 25 }
iscsiNewObjectsV2 OBJECT-GROUP
OBJECTS {
iscsiInstXNodeArchitecture,
iscsiSsnTaskReporting,
iscsiSsnProtocolLevel,
iscsiSsnNopReceivedPDUs,
iscsiSsnNopSentPDUs,
iscsiIntrLastTgtFailurePort,
iscsiTgtLastIntrFailurePort,
iscsiPortalDescr,
iscsiInstSsnTgtUnmappedErrors,
iscsiTgtLogoutCxnClosed,
iscsiTgtLogoutCxnRemoved
}
STATUS current
DESCRIPTION
"A collection of objects added in the second version of the
iSCSI MIB."
::= { iscsiGroups 26 }
--**********************************************************************
iscsiComplianceV1 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"Initial version of compliance statement.
Bakke & Venkatesen Standards Track [Page 82]
RFC 7147 iSCSI MIB April 2014
If an implementation can be both a target and an
initiator, all groups are mandatory.
This module compliance is deprecated because the
marker keys are obsolete."
REFERENCE
"RFC 7143, Section 13.25, Obsoleted Keys."
MODULE -- this module
MANDATORY-GROUPS {
iscsiInstanceAttributesGroup,
iscsiInstanceSsnErrorStatsGroup,
iscsiPortalAttributesGroup,
iscsiNodeAttributesGroup,
iscsiSessionAttributesGroup,
iscsiSessionPDUStatsGroup,
iscsiSessionCxnErrorStatsGroup,
iscsiConnectionAttributesGroup,
iscsiSsnFlrNotificationsGroup
}
-- Conditionally mandatory groups depending on the ability
-- to support Counter64 data types and/or to provide counter
-- information to SNMPv1 applications.
GROUP iscsiSessionOctetStatsGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that can support Counter64 data types."
GROUP iscsiSessionLCOctetStatsGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that provide information to SNMPv1-only applications;
this includes agents that cannot support Counter64
data types."
-- Conditionally mandatory groups to be included with
-- the mandatory groups when the implementation has
-- iSCSI target facilities.
GROUP iscsiTgtPortalAttributesGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI target facilities."
OBJECT iscsiPortalMaxRecvDataSegLength
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
Bakke & Venkatesen Standards Track [Page 83]
RFC 7147 iSCSI MIB April 2014
OBJECT iscsiNodeStorageType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required; an implementation may
choose to allow this object to be set to 'volatile'
or 'nonVolatile'."
GROUP iscsiTargetAttributesGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI target facilities."
GROUP iscsiTargetLoginStatsGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI target facilities."
GROUP iscsiTargetLogoutStatsGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI target facilities."
GROUP iscsiTgtLgnNotificationsGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI target facilities."
GROUP iscsiTargetAuthGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI target facilities."
-- Conditionally mandatory groups to be included with
-- the mandatory groups when the implementation has
-- iSCSI initiator facilities.
GROUP iscsiIntrPortalAttributesGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI initiator facilities."
GROUP iscsiInitiatorAttributesGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI initiator facilities."
GROUP iscsiInitiatorLoginStatsGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
Bakke & Venkatesen Standards Track [Page 84]
RFC 7147 iSCSI MIB April 2014
that have iSCSI initiator facilities."
GROUP iscsiInitiatorLogoutStatsGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI initiator facilities."
GROUP iscsiIntrLgnNotificationsGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI initiator facilities."
GROUP iscsiInitiatorAuthGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI initiator facilities."
OBJECT iscsiNodeErrorRecoveryLevel
SYNTAX Unsigned32 (0..2)
DESCRIPTION
"Only values 0-2 are defined at present."
::= { iscsiCompliances 1 }
iscsiComplianceV2 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Version 2 of compliance statement based on
this revised version of the MIB module.
If an implementation can be both a target and an
initiator, all groups are mandatory."
MODULE -- this module
MANDATORY-GROUPS {
iscsiInstanceAttributesGroup,
iscsiInstanceSsnErrorStatsGroup,
iscsiPortalAttributesGroupV2,
iscsiNodeAttributesGroup,
iscsiSessionAttributesGroup,
iscsiSessionPDUStatsGroup,
iscsiSessionCxnErrorStatsGroup,
iscsiConnectionAttributesGroupV2,
iscsiSsnFlrNotificationsGroup
}
-- Conditionally mandatory groups depending on the ability
-- to support Counter64 data types and/or to provide counter
-- information to SNMPv1 applications.
Bakke & Venkatesen Standards Track [Page 85]
RFC 7147 iSCSI MIB April 2014
GROUP iscsiSessionOctetStatsGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that can support Counter64 data types."
GROUP iscsiSessionLCOctetStatsGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that provide information to SNMPv1-only applications;
this includes agents that cannot support Counter64
data types."
-- Conditionally mandatory groups to be included with
-- the mandatory groups when the implementation has
-- iSCSI target facilities.
GROUP iscsiTgtPortalAttributesGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI target facilities."
OBJECT iscsiPortalMaxRecvDataSegLength
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT iscsiNodeStorageType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required; an implementation may
choose to allow this object to be set to 'volatile'
or 'nonVolatile'."
GROUP iscsiTargetAttributesGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI target facilities."
GROUP iscsiTargetLoginStatsGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI target facilities."
GROUP iscsiTargetLogoutStatsGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI target facilities."
Bakke & Venkatesen Standards Track [Page 86]
RFC 7147 iSCSI MIB April 2014
GROUP iscsiTgtLgnNotificationsGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI target facilities."
GROUP iscsiTargetAuthGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI target facilities."
-- Conditionally mandatory groups to be included with
-- the mandatory groups when the implementation has
-- iSCSI initiator facilities.
GROUP iscsiIntrPortalAttributesGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI initiator facilities."
GROUP iscsiInitiatorAttributesGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI initiator facilities."
GROUP iscsiInitiatorLoginStatsGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI initiator facilities."
GROUP iscsiInitiatorLogoutStatsGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI initiator facilities."
GROUP iscsiIntrLgnNotificationsGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI initiator facilities."
GROUP iscsiInitiatorAuthGroup
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that have iSCSI initiator facilities."
OBJECT iscsiNodeErrorRecoveryLevel
SYNTAX Unsigned32 (0..2)
DESCRIPTION
"Only values 0-2 are defined at present."
Bakke & Venkatesen Standards Track [Page 87]
RFC 7147 iSCSI MIB April 2014
GROUP iscsiNewObjectsV2
DESCRIPTION
"This group is mandatory for all iSCSI implementations
that support a value of the iSCSIProtocolLevel key of
2 or greater."
::= { iscsiCompliances 2 }
END
8. Security Considerations
There are a number of management objects defined in this MIB module
with a MAX-ACCESS clause of read-write and/or read-create. Such
objects may be considered sensitive or vulnerable in some network
environments. The support for SET operations in a non-secure
environment without proper protection can have a negative effect on
network operations. These are the tables and objects and their
sensitivity/vulnerability:
iscsiPortalAttributesTable, iscsiTgtPortalAttributesTable, and
iscsiIntrPortalAttributesTable can be used to add or remove IP
addresses to be used by iSCSI.
iscsiTgtAuthAttributesTable entries can be added or removed, to
allow or disallow access to a target by an initiator.
Some of the readable objects in this MIB module (i.e., objects with a
MAX-ACCESS other than not-accessible) may be considered sensitive or
vulnerable in some network environments. It is thus important to
control even GET and/or NOTIFY access to these objects and possibly
to even encrypt the values of these objects when sending them over
the network via SNMP. These are the tables and objects and their
sensitivity/vulnerability:
iscsiNodeAttributesTable, iscsiTargetAttributesTable, and
iscsiTgtAuthorization can be used to glean information needed to
make connections to the iSCSI targets this module represents.
However, it is the responsibility of the initiators and targets
involved to authenticate each other to ensure that an
inappropriately advertised or discovered initiator or target does
not compromise their security. These issues are discussed in
[RFC7143].
Bakke & Venkatesen Standards Track [Page 88]
RFC 7147 iSCSI MIB April 2014
SNMP versions prior to SNMPv3 did not include adequate security.
Even if the network itself is secure (for example by using IPsec),
even then, there is no control as to who on the secure network is
allowed to access and GET/SET (read/change/create/delete) the objects
in this MIB module.
Implementations SHOULD provide the security features described by the
SNMPv3 framework (see [RFC3410]), and implementations claiming
compliance to the SNMPv3 standard MUST include full support for
authentication and privacy via the User-based Security Model (USM)
[RFC3414] with the AES cipher algorithm [RFC3826]. Implementations
MAY also provide support for the Transport Security Model (TSM)
[RFC5591] in combination with a secure transport such as SSH
[RFC5592] or TLS/DTLS [RFC6353].
Further, deployment of SNMP versions prior to SNMPv3 is NOT
RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to
enable cryptographic security. It is then a customer/operator
responsibility to ensure that the SNMP entity giving access to an
instance of this MIB module is properly configured to give access to
the objects only to those principals (users) that have legitimate
rights to indeed GET or SET (change/create/delete) them.
9. IANA Considerations
The MIB module in this document uses the following IANA-assigned
OBJECT IDENTIFIER value recorded in the "SMI Network Management MGMT
Codes Internet-standard MIB" registry:
Descriptor OBJECT IDENTIFIER value
---------- -----------------------
iscsiMibModule { mib-2 142 }
IANA has updated the reference for the mib-2 142 identifier to refer
to this document.
10. References
10.1. Normative References
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC 2119, March 1997.
[RFC2578] McCloghrie, K., Ed., Perkins, D., Ed., and J.
Schoenwaelder, Ed., "Structure of Management Information
Version 2 (SMIv2)", STD 58, RFC 2578, April 1999.
Bakke & Venkatesen Standards Track [Page 89]
RFC 7147 iSCSI MIB April 2014
[RFC2579] McCloghrie, K., Ed., Perkins, D., Ed., and J.
Schoenwaelder, Ed., "Textual Conventions for SMIv2", STD
58, RFC 2579, April 1999.
[RFC2580] McCloghrie, K., Ed., Perkins, D., Ed., and J.
Schoenwaelder, Ed., "Conformance Statements for SMIv2",
STD 58, RFC 2580, April 1999.
[RFC3411] Harrington, D., Presuhn, R., and B. Wijnen, "An
Architecture for Describing Simple Network Management
Protocol (SNMP) Management Frameworks", STD 62, RFC 3411,
December 2002.
[RFC3414] Blumenthal, U. and B. Wijnen, "User-based Security Model
(USM) for version 3 of the Simple Network Management
Protocol (SNMPv3)", STD 62, RFC 3414, December 2002.
[RFC3720] Satran, J., Meth, K., Sapuntzakis, C., Chadalapaka, M.,
and E. Zeidner, "Internet Small Computer Systems Interface
(iSCSI)", RFC 3720, April 2004.
[RFC3826] Blumenthal, U., Maino, F., and K. McCloghrie, "The
Advanced Encryption Standard (AES) Cipher Algorithm in the
SNMP User-based Security Model", RFC 3826, June 2004.
[RFC4001] Daniele, M., Haberman, B., Routhier, S., and J.
Schoenwaelder, "Textual Conventions for Internet Network
Addresses", RFC 4001, February 2005.
[RFC4545] Bakke, M. and J. Muchow, "Definitions of Managed Objects
for IP Storage User Identity Authorization", RFC 4545, May
2006.
[RFC5591] Harrington, D. and W. Hardaker, "Transport Security Model
for the Simple Network Management Protocol (SNMP)", RFC
5591, June 2009.
[RFC5592] Harrington, D., Salowey, J., and W. Hardaker, "Secure
Shell Transport Model for the Simple Network Management
Protocol (SNMP)", RFC 5592, June 2009.
[RFC6353] Hardaker, W., "Transport Layer Security (TLS) Transport
Model for the Simple Network Management Protocol (SNMP)",
RFC 6353, July 2011.
[RFC7143] Chadalapaka, M., Satran, J., Meth, K., and D. Black,
"Internet Small Computer System Interface (iSCSI) Protocol
(Consolidated)", RFC 7143, April 2014.
Bakke & Venkatesen Standards Track [Page 90]
RFC 7147 iSCSI MIB April 2014
[RFC7144] Knight, F. and M. Chadalapaka, "Internet Small Computer
System Interface (iSCSI) SCSI Features Update", RFC 7144,
April 2014.
10.2. Informative References
[RFC3410] Case, J., Mundy, R., Partain, D., and B. Stewart,
"Introduction and Applicability Statements for Internet-
Standard Management Framework", RFC 3410, December 2002.
[RFC4022] Raghunarayan, R., Ed., "Management Information Base for
the Transmission Control Protocol (TCP)", RFC 4022, March
2005.
[RFC4455] Hallak-Stamler, M., Bakke, M., Lederman, Y., Krueger, M.,
and K. McCloghrie, "Definition of Managed Objects for
Small Computer System Interface (SCSI) Entities", RFC
4455, April 2006.
[RFC4544] Bakke, M., Krueger, M., McSweeney, T., and J. Muchow,
"Definitions of Managed Objects for Internet Small
Computer System Interface (iSCSI)", RFC 4544, May 2006.
11. Acknowledgments
The contents of this document were largely written as RFC 4544 by
Mark Bakke (Cisco), Marjorie Krueger (Hewlett-Packard), Tom McSweeney
(IBM), and James Muchow (QLogic). A special thank you to Marjorie,
Tom, and James for their hard work and especially to James for his
attention to detail on this work.
In addition to the authors, several people contributed to the
development of this MIB module. Thanks especially to those who took
the time to participate in our weekly conference calls to build our
requirements, object models, table structures, and attributes: John
Hufferd, Tom McSweeney (IBM), Kevin Gibbons (Nishan Systems), Chad
Gregory (Intel), Jack Harwood (EMC), Hari Mudaliar (Adaptec), Ie Wei
Njoo (Agilent), Lawrence Lamers (SAN Valley), Satish Mali (Stonefly
Networks), and William Terrell (Troika).
Special thanks to Tom McSweeney, Ie Wei Njoo, and Kevin Gibbons, who
wrote the descriptions for many of the tables and attributes in this
MIB module, to Ayman Ghanem for finding and suggesting changes for
many problems in this module, and to Keith McCloghrie for serving as
advisor to the team.
Thanks to Mike MacFaden (VMWare), David Black (EMC), and Tom Talpey
(Microsoft) for their valuable inputs.
Bakke & Venkatesen Standards Track [Page 91]
RFC 7147 iSCSI MIB April 2014
Authors' Addresses
Mark Bakke
Dell
7625 Smetana Lane
Eden Prairie, MN 55344
USA
EMail: mark_bakke@dell.com
Prakash Venkatesen
HCL Technologies Ltd.
50-53, Greams Road,
Chennai - 600006
India
EMail: prakashvn@hcl.com
Bakke & Venkatesen Standards Track [Page 92]