[RFC Home] [TEXT|PDF|HTML] [Tracker] [IPR] [Info page]

Obsoleted by: 2863 PROPOSED STANDARD
Network Working Group                                      K. McCloghrie
Request for Comments: 2233                                 Cisco Systems
Obsoletes: 1573                                            F. Kastenholz
Category: Standards Track                                   FTP Software
                                                           November 1997


                  The Interfaces Group MIB using SMIv2


Status of this Memo

   This document specifies an Internet standards track protocol for the
   Internet community, and requests discussion and suggestions for
   improvements.  Please refer to the current edition of the "Internet
   Official Protocol Standards" (STD 1) for the standardization state
   and status of this protocol.  Distribution of this memo is unlimited.

Copyright Notice

   Copyright (C) The Internet Society (1997).  All Rights Reserved.

Table of Contents

   1 Introduction ..............................................    2
   2 The SNMP Network Management Framework .....................    2
   2.1 Object Definitions ......................................    3
   3 Experience with the Interfaces Group ......................    3
   3.1 Clarifications/Revisions ................................    3
   3.1.1 Interface Sub-Layers ..................................    4
   3.1.2 Guidance on Defining Sub-layers .......................    6
   3.1.3 Virtual Circuits ......................................    8
   3.1.4 Bit, Character, and Fixed-Length Interfaces ...........    8
   3.1.5 Interface Numbering ...................................   10
   3.1.6 Counter Size ..........................................   14
   3.1.7 Interface Speed .......................................   16
   3.1.8 Multicast/Broadcast Counters ..........................   17
   3.1.9 Trap Enable ...........................................   18
   3.1.10 Addition of New ifType values ........................   18
   3.1.11 InterfaceIndex Textual Convention ....................   18
   3.1.12 New states for IfOperStatus ..........................   19
   3.1.13 IfAdminStatus and IfOperStatus .......................   20
   3.1.14 IfOperStatus in an Interface Stack ...................   21
   3.1.15 Traps ................................................   21
   3.1.16 ifSpecific ...........................................   23
   3.1.17 Creation/Deletion of Interfaces ......................   24
   3.1.18 All Values Must be Known .............................   24
   4 Media-Specific MIB Applicability ..........................   25



McCloghrie & Kastenholz     Standards Track                     [Page 1]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   5 Overview ..................................................   26
   6 Interfaces Group Definitions ..............................   26
   7 Acknowledgements ..........................................   64
   8 References ................................................   64
   9 Security Considerations ...................................   65
   10 Authors' Addresses .......................................   65
   11 Full Copyright Statement .................................   66

1.  Introduction

   This memo defines a portion of the Management Information Base
   (MIB) for use with network management protocols in the Internet
   community.  In particular, it describes managed objects used for
   managing Network Interfaces.

   This memo discusses the 'interfaces' group of MIB-II, especially the
   experience gained from the definition of numerous media- specific MIB
   modules for use in conjunction with the 'interfaces' group for
   managing various sub-layers beneath the internetwork- layer.  It
   specifies clarifications to, and extensions of, the architectural
   issues within the previous model used for the 'interfaces' group.

   This memo also includes a MIB module.  As well as including new
   MIB definitions to support the architectural extensions, this MIB
   module also re-specifies the 'interfaces' group of MIB-II in a
   manner that is both compliant to the SNMPv2 SMI and semantically-
   identical to the existing SNMPv1-based definitions.

   The key words "MUST" and "MUST NOT" in this document are to be
   interpreted as described in RFC 2119 [10].

2.  The SNMP Network Management Framework

   The SNMP Network Management Framework presently consists of three
   major components.  They are:

   o    RFC 1902 which defines the SMI, the mechanisms used for
        describing and naming objects for the purpose of management.

   o    STD 17, RFC 1213 defines MIB-II, the core set of managed
        objects for the Internet suite of protocols.

   o    STD 15, RFC 1157 and RFC 1905 which define two versions of
        the protocol used for network access to managed objects.







McCloghrie & Kastenholz     Standards Track                     [Page 2]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   The Framework permits new objects to be defined for the purpose of
   experimentation and evaluation.

2.1.  Object Definitions

   Managed objects are accessed via a virtual information store,
   termed the Management Information Base or MIB.  Objects in the MIB
   are defined using the subset of Abstract Syntax Notation One
   (ASN.1) defined in the SMI.  In particular, each object object
   type is named by an OBJECT IDENTIFIER, an administratively
   assigned name.  The object type together with an object instance
   serves to uniquely identify a specific instantiation of the
   object.  For human convenience, we often use a textual string,
   termed the descriptor, to refer to the object type.

3.  Experience with the Interfaces Group

   One of the strengths of internetwork-layer protocols such as IP
   [6] is that they are designed to run over any network interface.
   In achieving this, IP considers any and all protocols it runs over
   as a single "network interface" layer.  A similar view is taken by
   other internetwork-layer protocols.  This concept is represented
   in MIB-II by the 'interfaces' group which defines a generic set of
   managed objects such that any network interface can be managed in
   an interface-independent manner through these managed objects.
   The 'interfaces' group provides the means for additional managed
   objects specific to particular types of network interface (e.g., a
   specific medium such as Ethernet) to be defined as extensions to
   the 'interfaces' group for media-specific management.  Since the
   standardization of MIB-II, many such media-specific MIB modules
   have been defined.

   Experience in defining these media-specific MIB modules has shown
   that the model defined by MIB-II is too simplistic and/or static
   for some types of media-specific management.  As a result, some of
   these media-specific MIB modules assume an evolution or loosening
   of the model.  This memo documents and standardizes that evolution
   of the model and fills in the gaps caused by that evolution.  This
   memo also incorporates the interfaces group extensions documented
   in RFC 1229 [7].

3.1.  Clarifications/Revisions

   There are several areas for which experience has indicated that
   clarification, revision, or extension of the model would be
   helpful.  The following sections discuss the changes in the
   interfaces group adopted by this memo in each of these areas.




McCloghrie & Kastenholz     Standards Track                     [Page 3]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   In some sections, one or more paragraphs contain discussion of
   rejected alternatives to the model adopted in this memo.  Readers
   not familiar with the MIB-II model and not interested in the
   rationale behind the new model may want to skip these paragraphs.

3.1.1.  Interface Sub-Layers

   Experience in defining media-specific management information has
   shown the need to distinguish between the multiple sub-layers
   beneath the internetwork-layer.  In addition, there is a need to
   manage these sub-layers in devices (e.g., MAC-layer bridges) which
   are unaware of which, if any, internetwork protocols run over
   these sub-layers.  As such, a model of having a single conceptual
   row in the interfaces table (MIB-II's ifTable) represent a whole
   interface underneath the internetwork-layer, and having a single
   associated media-specific MIB module (referenced via the ifType
   object) is too simplistic.  A further problem arises with the
   value of the ifType object which has enumerated values for each
   type of interface.

   Consider, for example, an interface with PPP running over an HDLC
   link which uses a RS232-like connector.  Each of these sub-layers
   has its own media-specific MIB module.  If all of this is
   represented by a single conceptual row in the ifTable, then an
   enumerated value for ifType is needed for that specific
   combination which maps to the specific combination of media-
   specific MIBs.  Furthermore, such a model still lacks a method to
   describe the relationship of all the sub-layers of the MIB stack.

   An associated problem is that of upward and downward multiplexing
   of the sub-layers.  An example of upward multiplexing is MLP
   (Multi-Link-Procedure) which provides load-sharing over several
   serial lines by appearing as a single point-to-point link to the
   sub-layer(s) above.  An example of downward multiplexing would be
   several instances of PPP, each framed within a separate X.25
   virtual circuit, all of which run over one fractional T1 channel,
   concurrently with other uses of the T1 link.  The MIB structure
   must allow these sorts of relationships to be described.

   Several solutions for representing multiple sub-layers were
   rejected.  One was to retain the concept of one conceptual row for
   all the sub-layers of an interface and have each media-specific
   MIB module identify its "superior" and "subordinate" sub-layers
   through OBJECT IDENTIFIER "pointers".  This scheme would have
   several drawbacks: the superior/subordinate pointers would be
   contained in the media-specific MIB modules; thus, a manager could
   not learn the structure of an interface without inspecting
   multiple pointers in different MIB modules; this would be overly



McCloghrie & Kastenholz     Standards Track                     [Page 4]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   complex and only possible if the manager had knowledge of all the
   relevant media-specific MIB modules; MIB modules would all need to
   be retrofitted with these new "pointers"; this scheme would not
   adequately address the problem of upward and downward
   multiplexing; and finally, enumerated values of ifType would be
   needed for each combination of sub-layers.  Another rejected
   solution also retained the concept of one conceptual row for all
   the sub-layers of an interface but had a new separate MIB table to
   identify the "superior" and "subordinate" sub-layers and to
   contain OBJECT IDENTIFIER "pointers" to the media-specific MIB
   module for each sub-layer.  Effectively, one conceptual row in the
   ifTable would represent each combination of sub-layers between the
   internetwork-layer and the wire.  While this scheme has fewer
   drawbacks, it still would not support downward multiplexing, such
   as PPP over MLP: observe that MLP makes two (or more) serial
   lines appear to the layers above as a single physical interface,
   and thus PPP over MLP should appear to the internetwork-layer as a
   single interface; in contrast, this scheme would result in two (or
   more) conceptual rows in the ifTable, both of which the
   internetwork-layer would run over.  This scheme would also require
   enumerated values of ifType for each combination of sub-layers.

   The solution adopted by this memo is to have an individual
   conceptual row in the ifTable to represent each sub-layer, and
   have a new separate MIB table (the ifStackTable, see section 6
   below) to identify the "superior" and "subordinate" sub-layers
   through INTEGER "pointers" to the appropriate conceptual rows in
   the ifTable.  This solution supports both upward and downward
   multiplexing, allows the IANAifType to Media-Specific MIB mapping
   to identify the media-specific MIB module for that sub-layer, such
   that the new table need only be referenced to obtain information
   about layering, and it only requires enumerated values of ifType
   for each sub-layer, not for combinations of them.  However, it
   does require that the descriptions of some objects in the ifTable
   (specifically, ifType, ifPhysAddress, ifInUcastPkts, and
   ifOutUcastPkts) be generalized so as to apply to any sub-layer
   (rather than only to a sub-layer immediately beneath the network
   layer as previously), plus some (specifically, ifSpeed) which need
   to have appropriate values identified for use when a generalized
   definition does not apply to a particular sub-layer.

   In addition, this adopted solution makes no requirement that a
   device, in which a sub-layer is instrumented by a conceptual row
   of the ifTable, be aware of whether an internetwork protocol runs
   on top of (i.e., at some layer above) that sub-layer.  In fact,
   the counters of packets received on an interface are defined as
   counting the number "delivered to a higher-layer protocol".  This
   meaning of "higher-layer" includes:



McCloghrie & Kastenholz     Standards Track                     [Page 5]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   (1)  Delivery to a forwarding module which accepts
        packets/frames/octets and forwards them on at the same
        protocol layer.  For example, for the purposes of this
        definition, the forwarding module of a MAC-layer bridge is
        considered as a "higher-layer" to the MAC-layer of each port
        on the bridge.

   (2)  Delivery to a higher sub-layer within a interface stack.  For
        example, for the purposes of this definition, if a PPP module
        operated directly over a serial interface, the PPP module
        would be considered the higher sub-layer to the serial
        interface.

   (3)  Delivery to a higher protocol layer which does not do packet
        forwarding for sub-layers that are "at the top of" the
        interface stack.  For example, for the purposes of this
        definition, the local IP module would be considered the
        higher layer to a SLIP serial interface.

   Similarly, for output, the counters of packets transmitted out an
   interface are defined as counting the number "that higher-level
   protocols requested to be transmitted".  This meaning of "higher-
   layer" includes:

   (1)  A forwarding module, at the same protocol layer, which
        transmits packets/frames/octets that were received on an
        different interface.  For example, for the purposes of this
        definition, the forwarding module of a MAC-layer bridge is
        considered as a "higher-layer" to the MAC-layer of each port
        on the bridge.

   (2)  The next higher sub-layer within an interface stack.  For
        example, for the purposes of this definition, if a PPP module
        operated directly over a serial interface, the PPP module
        would be a "higher layer" to the serial interface.

   (3)  For sub-layers that are "at the top of" the interface stack,
        a higher element in the network protocol stack.  For example,
        for the purposes of this definition, the local IP module
        would be considered the higher layer to an Ethernet
        interface.

3.1.2.  Guidance on Defining Sub-layers

   The designer of a media-specific MIB must decide whether to divide
   the interface into sub-layers or not, and if so, how to make the
   divisions.  The following guidance is offered to assist the
   media-specific MIB designer in these decisions.



McCloghrie & Kastenholz     Standards Track                     [Page 6]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   In general, the number of entries in the ifTable should be kept to
   the minimum required for network management.  In particular, a
   group of related interfaces should be treated as a single
   interface with one entry in the ifTable providing that:

   (1)  None of the group of interfaces performs multiplexing for any
        other interface in the agent,
   (2)  There is a meaningful and useful way for all of the ifTable's
        information (e.g., the counters, and the status variables),
        and all of the ifTable's capabilities (e.g., write access to
        ifAdminStatus), to apply to the group of interfaces as a
        whole.

   Under these circumstances, there should be one entry in the
   ifTable for such a group of interfaces, and any internal structure
   which needs to be represented to network management should be
   captured in a MIB module specific to the particular type of
   interface.

   Note that application of bullet 2 above to the ifTable's ifType
   object requires that there is a meaningful media-specific MIB and
   a meaningful ifType value which apply to the group of interfaces
   as a whole.  For example, it is not appropriate to treat an HDLC
   sub-layer and an RS-232 sub-layer as a single ifTable entry when
   the media-specific MIBs and the ifType values for HDLC and RS-232
   are separate (rather than combined).

   Subject to the above, it is appropriate to assign an ifIndex value
   to any interface that can occur in an interface stack (in the
   ifStackTable) where the bottom of the stack is a physical
   interface (ifConnectorPresent has the value 'true') and there is a
   layer-3 or other application that "points down" to the top of this
   stack.  An example of an application that points down to the top
   of the stack is the Character MIB [9].

   Note that the sub-layers of an interface on one device will
   sometimes be different from the sub-layers of the interconnected
   interface of another device; for example, for a frame-relay DTE
   interface connected a frameRelayService interface, the inter-
   connected DTE and DCE interfaces have different ifType values and
   media-specific MIBs.

   These guidelines are just that, guidelines.  The designer of a
   media-specific MIB is free to lay out the MIB in whatever SMI
   conformant manner is desired.  However, in doing so, the media-
   specific MIB MUST completely specify the sub-layering model used
   for the MIB, and provide the assumptions, reasoning, and rationale
   used to develop that model.



McCloghrie & Kastenholz     Standards Track                     [Page 7]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


3.1.3.  Virtual Circuits

   Several of the sub-layers for which media-specific MIB modules
   have been defined are connection oriented (e.g., Frame Relay,
   X.25).  Experience has shown that each effort to define such a MIB
   module revisits the question of whether separate conceptual rows
   in the ifTable are needed for each virtual circuit.  Most, if not
   all, of these efforts to date have decided to have all virtual
   circuits reference a single conceptual row in the ifTable.

   This memo strongly recommends that connection-oriented sub-layers
   do not have a conceptual row in the ifTable for each virtual
   circuit.  This avoids the proliferation of conceptual rows,
   especially those which have considerable redundant information.
   (Note, as a comparison, that connection-less sub-layers do not
   have conceptual rows for each remote address.)  There may,
   however, be circumstances under which it is appropriate for a
   virtual circuit of a connection-oriented sub-layer to have its own
   conceptual row in the ifTable; an example of this might be PPP
   over an X.25 virtual circuit.  The MIB in section 6 of this memo
   supports such circumstances.

   If a media-specific MIB wishes to assign an entry in the ifTable
   to each virtual circuit, the MIB designer must present the
   rationale for this decision in the media-specific MIB's
   specification.

3.1.4.  Bit, Character, and Fixed-Length Interfaces

   RS-232 is an example of a character-oriented sub-layer over which
   (e.g., through use of PPP) IP datagrams can be sent.  Due to the
   packet-based nature of many of the objects in the ifTable,
   experience has shown that it is not appropriate to have a
   character-oriented sub-layer represented by a whole conceptual row
   in the ifTable.

   Experience has also shown that it is sometimes desirable to have
   some management information for bit-oriented interfaces, which are
   similarly difficult to represent by a whole conceptual row in the
   ifTable.  For example, to manage the channels of a DS1 circuit,
   where only some of the channels are carrying packet-based data.

   A further complication is that some subnetwork technologies
   transmit data in fixed length transmission units.  One example of
   such a technology is cell relay, and in particular Asynchronous
   Transfer Mode (ATM), which transmits data in fixed-length cells.
   Representing such a interface as a packet-based interface produces




McCloghrie & Kastenholz     Standards Track                     [Page 8]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   redundant objects if the relationship between the number of
   packets and the number of octets in either direction is fixed by
   the size of the transmission unit (e.g., the size of a cell).

   About half the objects in the ifTable are applicable to every type
   of interface: packet-oriented, character-oriented, and bit-
   oriented.  Of the other half, two are applicable to both
   character-oriented and packet-oriented interfaces, and the rest
   are applicable only to packet-oriented interfaces.  Thus, while it
   is desirable for consistency to be able to represent any/all types
   of interfaces in the ifTable, it is not possible to implement the
   full ifTable for bit- and character-oriented sub-layers.

   A rejected solution to this problem would be to split the ifTable
   into two (or more) new MIB tables, one of which would contain
   objects that are relevant only to packet-oriented interfaces
   (e.g., PPP), and another that may be used by all interfaces.  This
   is highly undesirable since it would require changes in every
   agent implementing the ifTable (i.e., just about every existing
   SNMP agent).

   The solution adopted in this memo builds upon the fact that
   compliance statements in SNMPv2 (in contrast to SNMPv1) refer to
   object groups, where object groups are explicitly defined by
   listing the objects they contain.  Thus, in SNMPv2, multiple
   compliance statements can be specified, one for all interfaces and
   additional ones for specific types of interfaces.  The separate
   compliance statements can be based on separate object groups,
   where the object group for all interfaces can contain only those
   objects from the ifTable which are appropriate for every type of
   interfaces.  Using this solution, every sub-layer can have its own
   conceptual row in the ifTable.

   Thus, section 6 of this memo contains definitions of the objects
   of the existing 'interfaces' group of MIB-II, in a manner which is
   both SNMPv2-compliant and semantically-equivalent to the existing
   MIB-II definitions.  With equivalent semantics, and with the BER
   ("on the wire") encodings unchanged, these definitions retain the
   same OBJECT IDENTIFIER values as assigned by MIB-II.  Thus, in
   general, no rewrite of existing agents which conform to MIB-II and
   the ifExtensions MIB is required.

   In addition, this memo defines several object groups for the
   purposes of defining which objects apply to which types of
   interface:






McCloghrie & Kastenholz     Standards Track                     [Page 9]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   (1)  the ifGeneralInformationGroup.  This group contains those
        objects applicable to all types of network interfaces,
        including bit-oriented interfaces.

   (2)  the ifPacketGroup.  This group contains those objects
        applicable to packet-oriented network interfaces.

   (3)  the ifFixedLengthGroup.  This group contains the objects
        applicable not only to character-oriented interfaces, such as
        RS-232, but also to those subnetwork technologies, such as
        cell-relay/ATM, which transmit data in fixed length
        transmission units.  As well as the octet counters, there are
        also a few other counters (e.g., the error counters) which
        are useful for this type of interface, but are currently
        defined as being packet-oriented.  To accommodate this, the
        definitions of these counters are generalized to apply to
        character-oriented interfaces and fixed-length-transmission
        interfaces.

   It should be noted that the octet counters in the ifTable
   aggregate octet counts for unicast and non-unicast packets into a
   single octet counter per direction (received/transmitted).  Thus,
   with the above definition of fixed-length-transmission interfaces,
   where such interfaces which support non-unicast packets, separate
   counts of unicast and multicast/broadcast transmissions can only
   be maintained in a media-specific MIB module.

3.1.5.  Interface Numbering

   MIB-II defines an object, ifNumber, whose value represents:

        "The number of network interfaces (regardless of their
        current state) present on this system."

   Each interface is identified by a unique value of the ifIndex
   object, and the description of ifIndex constrains its value as
   follows:

        "Its value ranges between 1 and the value of ifNumber.  The
        value for each interface must remain constant at least from
        one re-initialization of the entity's network management
        system to the next re-initialization."

   This constancy requirement on the value of ifIndex for a
   particular interface is vital for efficient management.  However,
   an increasing number of devices allow for the dynamic
   addition/removal of network interfaces.  One example of this is a
   dynamic ability to configure the use of SLIP/PPP over a



McCloghrie & Kastenholz     Standards Track                    [Page 10]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   character-oriented port.  For such dynamic additions/removals, the
   combination of the constancy requirement and the restriction that
   the value of ifIndex is less than ifNumber is problematic.

   Redefining ifNumber to be the largest value of ifIndex was
   rejected since it would not help.  Such a re-definition would
   require ifNumber to be deprecated and the utility of the redefined
   object would be questionable.  Alternatively, ifNumber could be
   deprecated and not replaced.  However, the deprecation of ifNumber
   would require a change to that portion of ifIndex's definition
   which refers to ifNumber.  So, since the definition of ifIndex
   must be changed anyway in order to solve the problem, changes to
   ifNumber do not benefit the solution.

   The solution adopted in this memo is just to delete the
   requirement that the value of ifIndex must be less than the value
   of ifNumber, and to retain ifNumber with its current definition.
   This is a minor change in the semantics of ifIndex; however, all
   existing agent implementations conform to this new definition, and
   in the interests of not requiring changes to existing agent
   implementations and to the many existing media-specific MIBs, this
   memo assumes that this change does not require ifIndex to be
   deprecated.  Experience indicates that this assumption does
   "break" a few management applications, but this is considered
   preferable to breaking all agent implementations.

   This solution also results in the possibility of "holes" in the
   ifTable, i.e., the ifIndex values of conceptual rows in the
   ifTable are not necessarily contiguous, but SNMP's GetNext (and
   SNMPv2's GetBulk) operation easily deals with such holes.  The
   value of ifNumber still represents the number of conceptual rows,
   which increases/decreases as new interfaces are dynamically
   added/removed.

   The requirement for constancy (between re-initializations) of an
   interface's ifIndex value is met by requiring that after an
   interface is dynamically removed, its ifIndex value is not re-used
   by a *different* dynamically added interface until after the
   following re-initialization of the network management system.
   This avoids the need for assignment (in advance) of ifIndex values
   for all possible interfaces that might be added dynamically.  The
   exact meaning of a "different" interface is hard to define, and
   there will be gray areas.  Any firm definition in this document
   would likely to turn out to be inadequate.  Instead, implementors
   must choose what it means in their particular situation, subject
   to the following rules:





McCloghrie & Kastenholz     Standards Track                    [Page 11]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   (1)  a previously-unused value of ifIndex must be assigned to a
        dynamically added interface if an agent has no knowledge of
        whether the interface is the "same" or "different" to a
        previously incarnated interface.

   (2)  a management station, not noticing that an interface has gone
        away and another has come into existence, must not be
        confused when calculating the difference between the counter
        values retrieved on successive polls for a particular ifIndex
        value.

   When the new interface is the same as an old interface, but a
   discontinuity in the value of the interface's counters cannot be
   avoided, the ifTable has (until now) required that a new ifIndex
   value be assigned to the returning interface.  That is, either all
   counter values have had to be retained during the absence of an
   interface in order to use the same ifIndex value on that
   interface's return, or else a new ifIndex value has had to be
   assigned to the returning interface.  Both alternatives have
   proved to be burdensome to some implementations:

   (1)  maintaining the counter values may not be possible (e.g., if
        they are maintained on removable hardware),

   (2)  using a new ifIndex value presents extra work for management
        applications.  While the potential need for such extra work
        is unavoidable on agent re-initializations, it is desirable
        to avoid it between re-initializations.

   To address this, a new object, ifCounterDiscontinuityTime, has
   been defined to record the time of the last discontinuity in an
   interface's counters.  By monitoring the value of this new object,
   a management application can now detect counter discontinuities
   without the ifIndex value of the interface being changed.  Thus,
   an agent which implements this new object should, when a new
   interface is the same as an old interface, retain that interface's
   ifIndex value and update if necessary the interface's value of
   ifCounterDiscontinuityTime.  With this new object, a management
   application must, when calculating differences between counter
   values retrieved on successive polls, discard any calculated
   difference for which the value of ifCounterDiscontinuityTime is
   different for the two polls.  (Note that this test must be
   performed in addition to the normal checking of sysUpTime to
   detect an agent re-initialization.)  Since such discards are a
   waste of network management processing and bandwidth, an agent
   should not update the value of ifCounterDiscontinuityTime unless
   absolutely necessary.




McCloghrie & Kastenholz     Standards Track                    [Page 12]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   While defining this new object is a change in the semantics of the
   ifTable counter objects, it is impractical to deprecate and
   redefine all these counters because of their wide deployment and
   importance.  Also, a survey of implementations indicates that many
   agents and management applications do not correctly implement this
   aspect of the current semantics (because of the burdensome issues
   mentioned above), such that the practical implications of such a
   change is small.  Thus, this breach of the SMI's rules is
   considered to be acceptable.

   Note, however, that the addition of ifCounterDiscontinuityTime
   does not change the fact that:

        It is necessary at certain times for the assignment of ifIndex
        values to change on a reinitialization of the agent (such as a
        reboot).

   The possibility of ifIndex value re-assignment must be
   accommodated by a management application whenever the value of
   sysUpTime is reset to zero.

   Note also that some agents support multiple "naming scopes", e.g.,
   for an SNMPv1 agent, multiple values of the SNMPv1 community
   string.  For such an agent (e.g., a CNM agent which supports a
   different subset of interfaces for different customers), there is
   no required relationship between the ifIndex values which identify
   interfaces in one naming scope and those which identify interfaces
   in another naming scope.  It is the agent's choice as to whether
   the same or different ifIndex values identify the same or
   different interfaces in different naming scopes.

   Because of the restriction of the value of ifIndex to be less than
   ifNumber, interfaces have been numbered with small integer values.
   This has led to the ability by humans to use the ifIndex values as
   (somewhat) user-friendly names for network interfaces (e.g.,
   "interface number 3").  With the relaxation of the restriction on
   the value of ifIndex, there is now the possibility that ifIndex
   values could be assigned as very large numbers (e.g., memory
   addresses).  Such numbers would be much less user-friendly.
   Therefore, this memo recommends that ifIndex values still be
   assigned as (relatively) small integer values starting at 1, even
   though the values in use at any one time are not necessarily
   contiguous.  (Note that this makes remembering which values have
   been assigned easy for agents which dynamically add new
   interfaces).






McCloghrie & Kastenholz     Standards Track                    [Page 13]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   A new problem is introduced by representing each sub-layer as an
   ifTable entry.  Previously, there usually was a simple, direct,
   mapping of interfaces to the physical ports on systems.  This
   mapping would be based on the ifIndex value.  However, by having
   an ifTable entry for each interface sub-layer, mapping from
   interfaces to physical ports becomes increasingly problematic.

   To address this issue, a new object, ifName, is added to the MIB.
   This object contains the device's local name (e.g., the name used
   at the device's local console) for the interface of which the
   relevant entry in the ifTable is a component.  For example,
   consider a router having an interface composed of PPP running over
   an RS-232 port.  If the router uses the name "wan1" for the
   (combined) interface, then the ifName objects for the
   corresponding PPP and RS-232 entries in the ifTable would both
   have the value "wan1".  On the other hand, if the router uses the
   name "wan1.1" for the PPP interface and "wan1.2" for the RS-232
   port, then the ifName objects for the corresponding PPP and RS-232
   entries in the ifTable would have the values "wan1.1" and
   "wan1.2", respectively.  As an another example, consider an agent
   which responds to SNMP queries concerning an interface on some
   other (proxied) device: if such a proxied device associates a
   particular identifier with an interface, then it is appropriate to
   use this identifier as the value of the interface's ifName, since
   the local console in this case is that of the proxied device.

   In contrast, the existing ifDescr object is intended to contain a
   description of an interface, whereas another new object, ifAlias,
   provides a location in which a network management application can
   store a non-volatile interface-naming value of its own choice.
   The ifAlias object allows a network manager to give one or more
   interfaces their own unique names, irrespective of any interface-
   stack relationship.  Further, the ifAlias name is non-volatile,
   and thus an interface must retain its assigned ifAlias value
   across reboots, even if an agent chooses a new ifIndex value for
   the interface.

3.1.6.  Counter Size

   As the speed of network media increase, the minimum time in which
   a 32 bit counter will wrap decreases.  For example, a 10Mbs stream
   of back-to-back, full-size packets causes ifInOctets to wrap in
   just over 57 minutes; at 100Mbs, the minimum wrap time is 5.7
   minutes, and at 1Gbs, the minimum is 34 seconds.  Requiring that
   interfaces be polled frequently enough not to miss a counter wrap
   is increasingly problematic.





McCloghrie & Kastenholz     Standards Track                    [Page 14]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   A rejected solution to this problem was to scale the counters; for
   example, ifInOctets could be changed to count received octets in,
   say, 1024 byte blocks.  While it would provide acceptable
   functionality at high rates of the counted-events, at low rates it
   suffers.  If there is little traffic on an interface, there might
   be a significant interval before enough of the counted-events
   occur to cause the scaled counter to be incremented.  Traffic
   would then appear to be very bursty, leading to incorrect
   conclusions of the network's performance.

   Instead, this memo adopts expanded, 64 bit, counters.  These
   counters are provided in new "high capacity" groups.  The old,
   32-bit, counters have not been deprecated.  The 64-bit counters
   are to be used only when the 32-bit counters do not provide enough
   capacity; that is, when the 32 bit counters could wrap too fast.

   For interfaces that operate at 20,000,000 (20 million) bits per
   second or less, 32-bit byte and packet counters MUST be used.  For
   interfaces that operate faster than 20,000,000 bits/second, and
   slower than 650,000,000 bits/second, 32-bit packet counters MUST
   be used and 64-bit octet counters MUST be used.  For interfaces
   that operate at 650,000,000 bits/second or faster, 64-bit packet
   counters AND 64-bit octet counters MUST be used.

   These speed thresholds were chosen as reasonable compromises based
   on the following:

   (1)  The cost of maintaining 64-bit counters is relatively high,
        so minimizing the number of agents which must support them is
        desirable.  Common interfaces (such as 10Mbs Ethernet) should
        not require them.

   (2)  64-bit counters are a new feature, introduced in SNMPv2.  It
        is reasonable to expect that support for them will be spotty
        for the immediate future.  Thus, we wish to limit them to as
        few systems as possible.  This, in effect, means that 64-bit
        counters should be limited to higher speed interfaces.
        Ethernet (10,000,000 bps) and Token Ring (16,000,000 bps) are
        fairly wide-spread so it seems reasonable to not require 64-
        bit counters for these interfaces.

   (3)  The 32-bit octet counters will wrap in the following times,
        for the following interfaces (when transmitting maximum-sized
        packets back-to-back):

        -   10Mbs Ethernet: 57 minutes,

        -   16Mbs Token Ring: 36 minutes,



McCloghrie & Kastenholz     Standards Track                    [Page 15]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


        -   a US T3 line (45 megabits): 12 minutes,

        -   FDDI: 5.7 minutes

   (4)  The 32-bit packet counters wrap in about 57 minutes when 64-
        byte packets are transmitted back-to-back on a 650,000,000
        bit/second link.

   As an aside, a 1-terabit/second (1,000 Gbs) link will cause a 64 bit
   octet counter to wrap in just under 5 years.  Conversely, an
   81,000,000 terabit/second link is required to cause a 64-bit counter
   to wrap in 30 minutes.  We believe that, while technology rapidly
   marches forward, this link speed will not be achieved for at least
   several years, leaving sufficient time to evaluate the introduction
   of 96 bit counters.

   When 64-bit counters are in use, the 32-bit counters MUST still be
   available.  They will report the low 32-bits of the associated 64-bit
   count (e.g., ifInOctets will report the least significant 32 bits of
   ifHCInOctets).  This enhances inter-operability with existing
   implementations at a very minimal cost to agents.

   The new "high capacity" groups are:

   (1)  the ifHCFixedLengthGroup for character-oriented/fixed-length
        interfaces, and the ifHCPacketGroup for packet-based interfaces;
        both of these groups include 64 bit counters for octets, and

   (2)  the ifVHCPacketGroup for packet-based interfaces; this group
        includes 64 bit counters for octets and packets.

3.1.7.  Interface Speed

   Network speeds are increasing.  The range of ifSpeed is limited to
   reporting a maximum speed of (2**31)-1 bits/second, or approximately
   2.2Gbs.  SONET defines an OC-48 interface, which is defined at
   operating at 48 times 51 Mbs, which is a speed in excess of 2.4Gbs.
   Thus, ifSpeed is insufficient for the future, and this memo defines
   an additional object: ifHighSpeed.

   The ifHighSpeed object reports the speed of the interface in
   1,000,000 (1 million) bits/second units.  Thus, the true speed of the
   interface will be the value reported by this object, plus or minus
   500,000 bits/second.







McCloghrie & Kastenholz     Standards Track                    [Page 16]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   Other alternatives considered (but rejected) were:

   (1)  Making the interface speed a 64-bit gauge.  This was rejected
        since the current SMI does not allow such a syntax.

        Furthermore, even if 64-bit gauges were available, their use
        would require additional complexity in agents due to an
        increased requirement for 64-bit operations.

   (2)  We also considered making "high-32 bit" and "low-32-bit"
        objects which, when combined, would be a 64-bit value.  This
        simply seemed overly complex for what we are trying to do.

        Furthermore, a full 64-bits of precision does not seem
        necessary.  The value of ifHighSpeed will be the only report of
        interface speed for interfaces that are faster than
        4,294,967,295 bits per second.  At this speed, the granularity
        of ifHighSpeed will be 1,000,000 bits per second, thus the error
        will be 1/4294, or about 0.02%.  This seems reasonable.

   (3)  Adding a "scale" object, which would define the units which
        ifSpeed's value is.

        This would require two additional objects; one for the scaling
        object, and one to replace the current ifSpeed.  This later
        object is required since the semantics of ifSpeed would be
        significantly altered, and manager stations which do not
        understand the new semantics would be confused.

3.1.8.  Multicast/Broadcast Counters

   In MIB-II, the ifTable counters for multicast and broadcast packets
   are combined as counters of non-unicast packets.  In contrast, the
   ifExtensions MIB [7] defined one set of counters for multicast, and a
   separate set for broadcast packets.  With the separate counters, the
   original combined counters become redundant.  To avoid this
   redundancy, the non-unicast counters are deprecated.

   For the output broadcast and multicast counters defined in RFC 1229,
   their definitions varied slightly from the packet counters in the
   ifTable, in that they did not count errors/discarded packets.  Thus,
   this memo defines new objects with better aligned definitions.
   Counters with 64 bits of range are also needed, as explained above.








McCloghrie & Kastenholz     Standards Track                    [Page 17]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


3.1.9.  Trap Enable

   In the multi-layer interface model, each sub-layer for which there is
   an entry in the ifTable can generate linkUp/Down Traps.  Since
   interface state changes would tend to propagate through the interface
   (from top to bottom, or bottom to top), it is likely that several
   traps would be generated for each linkUp/Down occurrence.

   It is desirable to provide a mechanism for manager stations to
   control the generation of these traps.  To this end, the
   ifLinkUpDownTrapEnable object has been added.  This object allows
   managers to limit generation of traps to just the sub-layers of
   interest.

   The default setting should limit the number of traps generated to one
   per interface per linkUp/Down event.  Furthermore, it seems that the
   state changes of most interest to network managers occur at the
   lowest level of an interface stack.  Therefore we specify that by
   default, only the lowest sub-layer of the interface generate traps.

3.1.10.  Addition of New ifType values

   Over time, there is the need to add new ifType enumerated values for
   new interface types.  If the syntax of ifType were defined in the MIB
   in section 6, then a new version of this MIB would have to be re-
   issued in order to define new values.  In the past, re- issuing of a
   MIB has occurred only after several years.

   Therefore, the syntax of ifType is changed to be a textual
   convention, such that the enumerated integer values are now defined
   in the textual convention, IANAifType, defined in a different
   document.  This allows additional values to be documented without
   having to re-issue a new version of this document.  The Internet
   Assigned Number Authority (IANA) is responsible for the assignment of
   all Internet numbers, including various SNMP-related numbers, and
   specifically, new ifType values.

3.1.11.  InterfaceIndex Textual Convention

   A new textual convention, InterfaceIndex, has been defined.  This
   textual convention "contains" all of the semantics of the ifIndex
   object.  This allows other mib modules to easily import the semantics
   of ifIndex.








McCloghrie & Kastenholz     Standards Track                    [Page 18]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


3.1.12.  New states for IfOperStatus

   Three new states have been added to ifOperStatus: 'dormant',
   'notPresent', and 'lowerLayerDown'.

   The dormant state indicates that the relevant interface is not
   actually in a condition to pass packets (i.e., it is not "up") but is
   in a "pending" state, waiting for some external event.  For "on-
   demand" interfaces, this new state identifies the situation where the
   interface is waiting for events to place it in the up state.
   Examples of such events might be:

   (1)  having packets to transmit before establishing a connection
        to a remote system;

   (2)  having a remote system establish a connection to the
        interface (e.g. dialing up to a slip-server).

   The notPresent state is a refinement on the down state which
   indicates that the relevant interface is down specifically because
   some component (typically, a hardware component) is not present in
   the managed system.  Examples of use of the notPresent state are:

   (1)  to allow an interface's conceptual row including its counter
        values to be retained across a "hot swap" of a card/module,
        and/or

   (2)  to allow an interface's conceptual row to be created, and
        thereby enable interfaces to be pre-configured prior to
        installation of the hardware needed to make the interface
        operational.

   Agents are not required to support interfaces in the notPresent
   state.  However, from a conceptual viewpoint, when a row in the
   ifTable is created, it first enters the notPresent state and then
   subsequently transitions into the down state; similarly, when a row
   in the ifTable is deleted, it first enters the notPresent state and
   then subsequently the object instances are deleted.  For an agent
   with no support for notPresent, both of these transitions (from the
   notPresent state to the down state, and from the notPresent state to
   the instances being removed) are immediate, i.e., the transition does
   not last long enough to be recorded by ifOperStatus.  Even for those
   agents which do support interfaces in the notPresent state, the
   length of time and conditions under which an interface stays in the
   notPresent state is implementation-specific.






McCloghrie & Kastenholz     Standards Track                    [Page 19]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   The lowerLayerDown state is also a refinement on the down state.
   This new state indicates that this interface runs "on top of" one or
   more other interfaces (see ifStackTable) and that this interface is
   down specifically because one or more of these lower-layer interfaces
   are down.

3.1.13.  IfAdminStatus and IfOperStatus

   The down state of ifOperStatus now has two meanings, depending on the
   value of ifAdminStatus.

   (1)  if ifAdminStatus is not down and ifOperStatus is down then a
        fault condition is presumed to exist on the interface.

   (2)  if ifAdminStatus is down, then ifOperStatus will normally
        also be down (or notPresent) i.e., there is not (necessarily) a
        fault condition on the interface.

   Note that when ifAdminStatus transitions to down, ifOperStatus will
   normally also transition to down.  In this situation, it is possible
   that ifOperStatus's transition will not occur immediately, but rather
   after a small time lag to complete certain operations before going
   "down"; for example, it might need to finish transmitting a packet.
   If a manager station finds that ifAdminStatus is down and
   ifOperStatus is not down for a particular interface, the manager
   station should wait a short while and check again.  If the condition
   still exists, only then should it raise an error indication.
   Naturally, it should also ensure that ifLastChange has not changed
   during this interval.

   Whenever an interface table entry is created (usually as a result of
   system initialization), the relevant instance of ifAdminStatus is set
   to down, and presumably ifOperStatus will be down or notPresent.

   An interface may be enabled in two ways: either as a result of
   explicit management action (e.g. setting ifAdminStatus to up) or as a
   result of the managed system's initialization process.  When
   ifAdminStatus changes to the up state, the related ifOperStatus
   should do one of the following:

   (1)  Change to the up state if and only if the interface is able
        to send and receive packets.

   (2)  Change to the lowerLayerDown state if and only if the
        interface is prevented from entering the up state because of the
        state of one or more of the interfaces beneath it in the
        interface stack.




McCloghrie & Kastenholz     Standards Track                    [Page 20]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   (3)  Change to the dormant state if and only if the interface is
        found to be operable, but the interface is waiting for other,
        external, events to occur before it can transmit or receive
        packets.  Presumably when the expected events occur, the
        interface will then change to the up state.

   (4)  Remain in the down state if an error or other fault condition
        is detected on the interface.

   (5)  Change to the unknown state if, for some reason, the state of
        the interface can not be ascertained.

   (6)  Change to the testing state if some test(s) must be performed
        on the interface. Presumably after completion of the test, the
        interface's state will change to up, dormant, or down, as
        appropriate.

   (7)  Remain in the notPresent state if interface components are
        missing.

3.1.14.  IfOperStatus in an Interface Stack

   When an interface is a part of an interface-stack, but is not the
   lowest interface in the stack, then:

   (1)  ifOperStatus has the value 'up' if it is able to pass packets
        due to one or more interfaces below it in the stack being 'up',
        irrespective of whether other interfaces below it are 'down',
        'dormant', 'notPresent', 'lowerLayerDown', 'unknown' or
        'testing'.

   (2)  ifOperStatus may have the value 'up' or 'dormant' if one or
        more interfaces below it in the stack are 'dormant', and all
        others below it are either 'down', 'dormant', 'notPresent',
        'lowerLayerDown', 'unknown' or 'testing'.

   (3)  ifOperStatus has the value 'lowerLayerDown' while all
        interfaces below it in the stack are either 'down',
        'notPresent', 'lowerLayerDown', or 'testing'.

3.1.15.  Traps

   The exact definition of when linkUp and linkDown traps are generated
   has been changed to reflect the changes to ifAdminStatus and
   ifOperStatus.






McCloghrie & Kastenholz     Standards Track                    [Page 21]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   Operational experience indicates that management stations are most
   concerned with an interface being in the down state and the fact that
   this state may indicate a failure.  Thus, it is most useful to
   instrument transitions into/out of either the up state or the down
   state.

   Instrumenting transitions into or out of the up state was rejected
   since it would have the drawback that a demand interface might have
   many transitions between up and dormant, leading to many linkUp traps
   and no linkDown traps.  Furthermore, if a node's only interface is
   the demand interface, then a transition to dormant would entail
   generation of a linkDown trap, necessitating bringing the link to the
   up state (and a linkUp trap)!!

   On the other hand, instrumenting transitions into or out of the down
   state (to/from all other states except notPresent) has the
   advantages:

   (1)  A transition into the down state (from a state other than
        notPresent) will occur when an error is detected on an
        interface.  Error conditions are presumably of great interest to
        network managers.

   (2)  Departing the down state (to a state other than the
        notPresent state) generally indicates that the interface is
        going to either up or dormant, both of which are considered
        "healthy" states.

   Furthermore, it is believed that generating traps on transitions into
   or out of the down state (except to/from the notPresent state) is
   generally consistent with current usage and interpretation of these
   traps by manager stations.

   Transitions to/from the notPresent state are concerned with the
   insertion and removal of hardware, and are outside the scope of these
   traps.

   Therefore, this memo defines that LinkUp and linkDown traps are
   generated on just after ifOperStatus leaves, or just before it
   enters, the down state, respectively; except that LinkUp and linkDown
   traps never generated on transitions to/from the notPresent state.

   Note that this definition allows a node with only one interface to
   transmit a linkDown trap before that interface goes down.  (Of
   course, when the interface is going down because of a failure
   condition, the linkDown trap probably cannot be successfully
   transmitted anyway.)




McCloghrie & Kastenholz     Standards Track                    [Page 22]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   Some interfaces perform a link "training" function when trying to
   bring the interface up.  In the event that such an interface were
   defective, then the training function would fail and the interface
   would remain down, and the training function might be repeated at
   appropriate intervals.  If the interface, while performing this
   training function, were considered to the in the testing state, then
   linkUp and linkDown traps would be generated for each start and end
   of the training function.  This is not the intent of the linkUp and
   linkDown traps, and therefore, while performing such a training
   function, the interface's state should be represented as down.

   An exception to the above generation of linkUp/linkDown traps on
   changes in ifOperStatus, occurs when an interface is "flapping",
   i.e., when it is rapidly oscillating between the up and down states.
   If traps were generated for each such oscillation, the network and
   the network management system would be flooded with unnecessary
   traps.  In such a situation, the agent should rate- limit its
   generation of traps.

3.1.16.  ifSpecific

   The original definition of the OBJECT IDENTIFIER value of ifSpecific
   was not sufficiently clear.  As a result, different implementors used
   it differently, and confusion resulted.  Some implementations set the
   value of ifSpecific to the OBJECT IDENTIFIER that defines the media-
   specific MIB, i.e., the "foo" of:

              foo OBJECT IDENTIFIER ::= { transmission xxx }

   while others set it to be OBJECT IDENTIFIER of the specific table or
   entry in the appropriate media-specific MIB (i.e., fooTable or
   fooEntry), while still others set it be the OBJECT IDENTIFIER of the
   index object of the table's row, including instance identifier,
   (i.e., fooIfIndex.ifIndex).  A definition based on the latter would
   not be sufficient unless it also allowed for media- specific MIBs
   which include several tables, where each table has its own
   (different) indexing.

   The only definition that can both be made explicit and can cover all
   the useful situations is to have ifSpecific be the most general value
   for the media-specific MIB module (the first example given above).
   This effectively makes it redundant because it contains no more
   information than is provided by ifType.  Thus, ifSpecific has been
   deprecated.







McCloghrie & Kastenholz     Standards Track                    [Page 23]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


3.1.17.  Creation/Deletion of Interfaces

   While some interfaces, for example, most physical interfaces, cannot
   be created via network management, other interfaces such as logical
   interfaces sometimes can be.  The ifTable contains only generic
   information about an interface.  Almost all 'create-able' interfaces
   have other, media-specific, information through which configuration
   parameters may be supplied prior to creating such an interface.
   Thus, the ifTable does not itself support the creation or deletion of
   an interface (specifically, it has no RowStatus [2] column).  Rather,
   if a particular interface type supports the dynamic creation and/or
   deletion of an interface of that type, then that media-specific MIB
   should include an appropriate RowStatus object (see the ATM LAN-
   Emulation Client MIB [8] for an example of a MIB which does this).
   Typically, when such a RowStatus object is created/deleted, then the
   conceptual row in the ifTable appears/disappears as a by-product, and
   an ifIndex value (chosen by the agent) is stored in an appropriate
   object in the media-specific MIB.

3.1.18.  All Values Must be Known

   There are a number of situations where an agent does not know the
   value of one or more objects for a particular interface.  In all such
   circumstances, an agent MUST NOT instantiate an object with an
   incorrect value; rather, it MUST respond with the appropriate
   error/exception condition (e.g., noSuchInstance for SNMPv2).

   One example is where an agent is unable to count the occurrences
   defined by one (or more) of the ifTable counters.  In this
   circumstance, the agent MUST NOT instantiate the particular counter
   with a value of, say, zero.  To do so would be to provide mis-
   information to a network management application reading the zero
   value, and thereby assuming that there have been no occurrences of
   the event (e.g., no input errors because ifInErrors is always zero).

   Sometimes the lack of knowledge of an object's value is temporary.
   For example, when the MTU of an interface is a configured value and a
   device dynamically learns the configured value through (after)
   exchanging messages over the interface (e.g., ATM LAN- Emulation
   [8]).  In such a case, the value is not known until after the ifTable
   entry has already been created.  In such a case, the ifTable entry
   should be created without an instance of the object whose value is
   unknown; later, when the value becomes known, the missing object can
   then be instantiated (e.g., the instance of ifMtu is only
   instantiated once the interface's MTU becomes known).






McCloghrie & Kastenholz     Standards Track                    [Page 24]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   As a result of this "known values" rule, management applications MUST
   be able to cope with the responses to retrieving the object instances
   within a conceptual row of the ifTable revealing that some of the
   row's columnar objects are missing/not available.

4.  Media-Specific MIB Applicability

   The exact use and semantics of many objects in this MIB are open to
   some interpretation.  This is a result of the generic nature of this
   MIB.  It is not always possible to come up with specific,
   unambiguous, text that covers all cases and yet preserves the generic
   nature of the MIB.

   Therefore, it is incumbent upon a media-specific MIB designer to,
   wherever necessary, clarify the use of the objects in this MIB with
   respect to the media-specific MIB.

   Specific areas of clarification include

   Layering Model
        The media-specific MIB designer MUST completely and
        unambiguously specify the layering model used.  Each individual
        sub-layer must be identified, as must the ifStackTable's
        portrayal of the relationship(s) between the sub-layers.

   Virtual Circuits
        The media-specific MIB designer MUST specify whether virtual
        circuits are assigned entries in the ifTable or not.  If they
        are, compelling rationale must be presented.

   ifRcvAddressTable
        The media-specific MIB designer MUST specify the applicability
        of the ifRcvAddressTable.

   ifType
        For each of the ifType values to which the media-specific MIB
        applies, it must specify the mapping of ifType values to media-
        specific MIB module(s) and instances of MIB objects within those
        modules.

   However, wherever this interface MIB is specific in the semantics,
   DESCRIPTION, or applicability of objects, the media-specific MIB
   designer MUST NOT change said semantics, DESCRIPTION, or
   applicability.







McCloghrie & Kastenholz     Standards Track                    [Page 25]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


5.  Overview

   This MIB consists of 4 tables:

   ifTable
        This table is the ifTable from MIB-II.

        ifXTable
        This table contains objects that have been added to the
        Interface MIB as a result of the Interface Evolution effort, or
        replacements for objects of the original (MIB-II) ifTable that
        were deprecated because the semantics of said objects have
        significantly changed.  This table also contains objects that
        were previously in the ifExtnsTable.

   ifStackTable
        This table contains objects that define the relationships among
        the sub-layers of an interface.

   ifRcvAddressTable
        This table contains objects that are used to define the media-
        level addresses which this interface will receive.  This table
        is a generic table.  The designers of media- specific MIBs must
        define exactly how this table applies to their specific MIB.

6.  Interfaces Group Definitions

   IF-MIB DEFINITIONS ::= BEGIN

   IMPORTS
       MODULE-IDENTITY, OBJECT-TYPE, Counter32, Gauge32, Counter64,
       Integer32, TimeTicks, mib-2,
       NOTIFICATION-TYPE                        FROM SNMPv2-SMI
       TEXTUAL-CONVENTION, DisplayString,
       PhysAddress, TruthValue, RowStatus,
       TimeStamp, AutonomousType, TestAndIncr   FROM SNMPv2-TC
       MODULE-COMPLIANCE, OBJECT-GROUP          FROM SNMPv2-CONF
       snmpTraps                                FROM SNMPv2-MIB
       IANAifType                               FROM IANAifType-MIB;












McCloghrie & Kastenholz     Standards Track                    [Page 26]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   ifMIB MODULE-IDENTITY
       LAST-UPDATED "9611031355Z"
       ORGANIZATION "IETF Interfaces MIB Working Group"
       CONTACT-INFO
               "   Keith McCloghrie
                   Cisco Systems, Inc.
                   170 West Tasman Drive
                   San Jose, CA  95134-1706
                   US

                   408-526-5260
                   kzm@cisco.com"
       DESCRIPTION
               "The MIB module to describe generic objects for
               network interface sub-layers.  This MIB is an updated
               version of MIB-II's ifTable, and incorporates the
               extensions defined in RFC 1229."
       REVISION      "9602282155Z"
       DESCRIPTION
               "Revisions made by the Interfaces MIB WG."
       REVISION      "9311082155Z"
       DESCRIPTION
               "Initial revision, published as part of RFC 1573."
       ::= { mib-2 31 }


   ifMIBObjects OBJECT IDENTIFIER ::= { ifMIB 1 }

   interfaces   OBJECT IDENTIFIER ::= { mib-2 2 }


   OwnerString ::= TEXTUAL-CONVENTION
       DISPLAY-HINT "255a"
       STATUS       current
       DESCRIPTION
               "This data type is used to model an administratively
               assigned name of the owner of a resource.  This
               information is taken from the NVT ASCII character set.
               It is suggested that this name contain one or more of
               the following: ASCII form of the manager station's
               transport address, management station name (e.g.,
               domain name), network management personnel's name,
               location, or phone number.  In some cases the agent
               itself will be the owner of an entry.  In these cases,
               this string shall be set to a string starting with
               'agent'."
       SYNTAX       OCTET STRING (SIZE(0..255))




McCloghrie & Kastenholz     Standards Track                    [Page 27]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   -- InterfaceIndex contains the semantics of ifIndex and
   -- should be used for any objects defined on other mib
   -- modules that need these semantics.

   InterfaceIndex ::= TEXTUAL-CONVENTION
       DISPLAY-HINT "d"
       STATUS       current
       DESCRIPTION
               "A unique value, greater than zero, for each interface
               or interface sub-layer in the managed system.  It is
               recommended that values are assigned contiguously
               starting from 1.  The value for each interface sub-
               layer must remain constant at least from one re-
               initialization of the entity's network management
               system to the next re-initialization."
       SYNTAX       Integer32 (1..2147483647)


   InterfaceIndexOrZero ::= TEXTUAL-CONVENTION
       DISPLAY-HINT "d"
       STATUS       current
       DESCRIPTION
               "This textual convention is an extension of the
               InterfaceIndex convention.  The latter defines a
               greater than zero value used to identify an interface
               or interface sub-layer in the managed system.  This
               extension permits the additional value of zero.  the
               value zero is object-specific and must therefore be
               defined as part of the description of any object which
               uses this syntax.  Examples of the usage of zero might
               include situations where interface was unknown, or
               when none or all interfaces need to be referenced."
       SYNTAX       Integer32 (0..2147483647)


   ifNumber  OBJECT-TYPE
       SYNTAX      Integer32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The number of network interfaces (regardless of their
               current state) present on this system."
       ::= { interfaces 1 }








McCloghrie & Kastenholz     Standards Track                    [Page 28]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   ifTableLastChange  OBJECT-TYPE
       SYNTAX      TimeTicks
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The value of sysUpTime at the time of the last
               creation or deletion of an entry in the ifTable.  If
               the number of entries has been unchanged since the
               last re-initialization of the local network management
               subsystem, then this object contains a zero value."
       ::= { ifMIBObjects 5 }


   -- the Interfaces table

   -- The Interfaces table contains information on the entity's
   -- interfaces.  Each sub-layer below the internetwork-layer
   -- of a network interface is considered to be an interface.

   ifTable OBJECT-TYPE
       SYNTAX      SEQUENCE OF IfEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
               "A list of interface entries.  The number of entries
               is given by the value of ifNumber."
       ::= { interfaces 2 }

   ifEntry OBJECT-TYPE
       SYNTAX      IfEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
               "An entry containing management information applicable
               to a particular interface."
       INDEX   { ifIndex }



       ::= { ifTable 1 }

   IfEntry ::=
       SEQUENCE {
           ifIndex                 InterfaceIndex,
           ifDescr                 DisplayString,
           ifType                  IANAifType,
           ifMtu                   Integer32,
           ifSpeed                 Gauge32,



McCloghrie & Kastenholz     Standards Track                    [Page 29]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


           ifPhysAddress           PhysAddress,
           ifAdminStatus           INTEGER,
           ifOperStatus            INTEGER,
           ifLastChange            TimeTicks,
           ifInOctets              Counter32,
           ifInUcastPkts           Counter32,
           ifInNUcastPkts          Counter32,  -- deprecated
           ifInDiscards            Counter32,
           ifInErrors              Counter32,
           ifInUnknownProtos       Counter32,
           ifOutOctets             Counter32,
           ifOutUcastPkts          Counter32,
           ifOutNUcastPkts         Counter32,  -- deprecated
           ifOutDiscards           Counter32,
           ifOutErrors             Counter32,
           ifOutQLen               Gauge32,    -- deprecated
           ifSpecific              OBJECT IDENTIFIER -- deprecated
       }


   ifIndex OBJECT-TYPE
       SYNTAX      InterfaceIndex
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "A unique value, greater than zero, for each
               interface.  It is recommended that values are assigned
               contiguously starting from 1.  The value for each
               interface sub-layer must remain constant at least from
               one re-initialization of the entity's network
               management system to the next re-initialization."
       ::= { ifEntry 1 }

   ifDescr OBJECT-TYPE
       SYNTAX      DisplayString (SIZE (0..255))
       MAX-ACCESS  read-only


       STATUS      current
       DESCRIPTION
               "A textual string containing information about the
               interface.  This string should include the name of the
               manufacturer, the product name and the version of the
               interface hardware/software."
       ::= { ifEntry 2 }






McCloghrie & Kastenholz     Standards Track                    [Page 30]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   ifType OBJECT-TYPE
       SYNTAX      IANAifType
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The type of interface.  Additional values for ifType
               are assigned by the Internet Assigned Numbers
               Authority (IANA), through updating the syntax of the
               IANAifType textual convention."
       ::= { ifEntry 3 }

   ifMtu OBJECT-TYPE
       SYNTAX      Integer32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The size of the largest packet which can be
               sent/received on the interface, specified in octets.
               For interfaces that are used for transmitting network
               datagrams, this is the size of the largest network
               datagram that can be sent on the interface."
       ::= { ifEntry 4 }

   ifSpeed OBJECT-TYPE
       SYNTAX      Gauge32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "An estimate of the interface's current bandwidth in
               bits per second.  For interfaces which do not vary in
               bandwidth or for those where no accurate estimation
               can be made, this object should contain the nominal
               bandwidth.  If the bandwidth of the interface is
               greater than the maximum value reportable by this
               object then this object should report its maximum
               value (4,294,967,295) and ifHighSpeed must be used to
               report the interace's speed.  For a sub-layer which
               has no concept of bandwidth, this object should be
               zero."
       ::= { ifEntry 5 }

   ifPhysAddress OBJECT-TYPE
       SYNTAX      PhysAddress
       MAX-ACCESS  read-only
       STATUS      current






McCloghrie & Kastenholz     Standards Track                    [Page 31]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


       DESCRIPTION
               "The interface's address at its protocol sub-layer.
               For example, for an 802.x interface, this object
               normally contains a MAC address.  The interface's
               media-specific MIB must define the bit and byte
               ordering and the format of the value of this object.
               For interfaces which do not have such an address
               (e.g., a serial line), this object should contain an
               octet string of zero length."
       ::= { ifEntry 6 }

   ifAdminStatus OBJECT-TYPE
       SYNTAX  INTEGER {
                   up(1),       -- ready to pass packets
                   down(2),
                   testing(3)   -- in some test mode
               }
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
               "The desired state of the interface.  The testing(3)
               state indicates that no operational packets can be
               passed.  When a managed system initializes, all
               interfaces start with ifAdminStatus in the down(2)
               state.  As a result of either explicit management
               action or per configuration information retained by
               the managed system, ifAdminStatus is then changed to
               either the up(1) or testing(3) states (or remains in
               the down(2) state)."
       ::= { ifEntry 7 }

   ifOperStatus OBJECT-TYPE
       SYNTAX  INTEGER {
                   up(1),        -- ready to pass packets
                   down(2),
                   testing(3),   -- in some test mode
                   unknown(4),   -- status can not be determined
                                 -- for some reason.
                   dormant(5),
                   notPresent(6),    -- some component is missing
                   lowerLayerDown(7) -- down due to state of
                                     -- lower-layer interface(s)
               }








McCloghrie & Kastenholz     Standards Track                    [Page 32]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The current operational state of the interface.  The
               testing(3) state indicates that no operational packets
               can be passed.  If ifAdminStatus is down(2) then
               ifOperStatus should be down(2).  If ifAdminStatus is
               changed to up(1) then ifOperStatus should change to
               up(1) if the interface is ready to transmit and
               receive network traffic; it should change to
               dormant(5) if the interface is waiting for external
               actions (such as a serial line waiting for an incoming
               connection); it should remain in the down(2) state if
               and only if there is a fault that prevents it from
               going to the up(1) state; it should remain in the
               notPresent(6) state if the interface has missing
               (typically, hardware) components."
       ::= { ifEntry 8 }

   ifLastChange OBJECT-TYPE
       SYNTAX      TimeTicks
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The value of sysUpTime at the time the interface
               entered its current operational state.  If the current
               state was entered prior to the last re-initialization
               of the local network management subsystem, then this
               object contains a zero value."
       ::= { ifEntry 9 }

   ifInOctets OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The total number of octets received on the interface,
               including framing characters.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."
       ::= { ifEntry 10 }







McCloghrie & Kastenholz     Standards Track                    [Page 33]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   ifInUcastPkts OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The number of packets, delivered by this sub-layer to
               a higher (sub-)layer, which were not addressed to a
               multicast or broadcast address at this sub-layer.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."
       ::= { ifEntry 11 }

   ifInNUcastPkts OBJECT-TYPE
       SYNTAX  Counter32
       MAX-ACCESS  read-only
       STATUS      deprecated
       DESCRIPTION
               "The number of packets, delivered by this sub-layer to
               a higher (sub-)layer, which were addressed to a
               multicast or broadcast address at this sub-layer.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime.

               This object is deprecated in favour of
               ifInMulticastPkts and ifInBroadcastPkts."
       ::= { ifEntry 12 }

   ifInDiscards OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The number of inbound packets which were chosen to be
               discarded even though no errors had been detected to
               prevent their being deliverable to a higher-layer
               protocol.  One possible reason for discarding such a
               packet could be to free up buffer space.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."



McCloghrie & Kastenholz     Standards Track                    [Page 34]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


       ::= { ifEntry 13 }

   ifInErrors OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "For packet-oriented interfaces, the number of inbound
               packets that contained errors preventing them from
               being deliverable to a higher-layer protocol.  For
               character-oriented or fixed-length interfaces, the
               number of inbound transmission units that contained
               errors preventing them from being deliverable to a
               higher-layer protocol.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."
       ::= { ifEntry 14 }

   ifInUnknownProtos OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "For packet-oriented interfaces, the number of packets
               received via the interface which were discarded
               because of an unknown or unsupported protocol.  For
               character-oriented or fixed-length interfaces that
               support protocol multiplexing the number of
               transmission units received via the interface which
               were discarded because of an unknown or unsupported
               protocol.  For any interface that does not support
               protocol multiplexing, this counter will always be 0.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."
       ::= { ifEntry 15 }










McCloghrie & Kastenholz     Standards Track                    [Page 35]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   ifOutOctets OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The total number of octets transmitted out of the
               interface, including framing characters.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."
       ::= { ifEntry 16 }

   ifOutUcastPkts OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The total number of packets that higher-level
               protocols requested be transmitted, and which were not
               addressed to a multicast or broadcast address at this
               sub-layer, including those that were discarded or not
               sent.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."
       ::= { ifEntry 17 }

   ifOutNUcastPkts OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      deprecated
       DESCRIPTION
               "The total number of packets that higher-level
               protocols requested be transmitted, and which were
               addressed to a multicast or broadcast address at this
               sub-layer, including those that were discarded or not
               sent.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime.





McCloghrie & Kastenholz     Standards Track                    [Page 36]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


               This object is deprecated in favour of
               ifOutMulticastPkts and ifOutBroadcastPkts."
       ::= { ifEntry 18 }

   ifOutDiscards OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The number of outbound packets which were chosen to
               be discarded even though no errors had been detected
               to prevent their being transmitted.  One possible
               reason for discarding such a packet could be to free
               up buffer space.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."
       ::= { ifEntry 19 }

   ifOutErrors OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "For packet-oriented interfaces, the number of
               outbound packets that could not be transmitted because
               of errors.  For character-oriented or fixed-length
               interfaces, the number of outbound transmission units
               that could not be transmitted because of errors.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."
       ::= { ifEntry 20 }


   ifOutQLen OBJECT-TYPE
       SYNTAX      Gauge32
       MAX-ACCESS  read-only
       STATUS      deprecated
       DESCRIPTION
               "The length of the output packet queue (in packets)."
       ::= { ifEntry 21 }





McCloghrie & Kastenholz     Standards Track                    [Page 37]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   ifSpecific OBJECT-TYPE
       SYNTAX      OBJECT IDENTIFIER
       MAX-ACCESS  read-only
       STATUS      deprecated
       DESCRIPTION
               "A reference to MIB definitions specific to the
               particular media being used to realize the interface.
               It is recommended that this value point to an instance
               of a MIB object in the media-specific MIB, i.e., that
               this object have the semantics associated with the
               InstancePointer textual convention defined in RFC
               1903.  In fact, it is recommended that the media-
               specific MIB specify what value ifSpecific should/can
               take for values of ifType.  If no MIB definitions
               specific to the particular media are available, the
               value should be set to the OBJECT IDENTIFIER { 0 0 }."
       ::= { ifEntry 22 }



   --
   --   Extension to the interface table
   --
   -- This table replaces the ifExtnsTable table.
   --

   ifXTable        OBJECT-TYPE
       SYNTAX      SEQUENCE OF IfXEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
               "A list of interface entries.  The number of entries
               is given by the value of ifNumber.  This table
               contains additional objects for the interface table."
       ::= { ifMIBObjects 1 }

   ifXEntry        OBJECT-TYPE
       SYNTAX      IfXEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
               "An entry containing additional management information
               applicable to a particular interface."
       AUGMENTS    { ifEntry }
       ::= { ifXTable 1 }






McCloghrie & Kastenholz     Standards Track                    [Page 38]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   IfXEntry ::=
       SEQUENCE {
           ifName                  DisplayString,
           ifInMulticastPkts       Counter32,
           ifInBroadcastPkts       Counter32,
           ifOutMulticastPkts      Counter32,
           ifOutBroadcastPkts      Counter32,
           ifHCInOctets            Counter64,
           ifHCInUcastPkts         Counter64,
           ifHCInMulticastPkts     Counter64,
           ifHCInBroadcastPkts     Counter64,
           ifHCOutOctets           Counter64,
           ifHCOutUcastPkts        Counter64,
           ifHCOutMulticastPkts    Counter64,
           ifHCOutBroadcastPkts    Counter64,
           ifLinkUpDownTrapEnable  INTEGER,
           ifHighSpeed             Gauge32,
           ifPromiscuousMode       TruthValue,
           ifConnectorPresent      TruthValue,
           ifAlias                 DisplayString,
           ifCounterDiscontinuityTime TimeStamp
       }


   ifName OBJECT-TYPE
       SYNTAX      DisplayString
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The textual name of the interface.  The value of this
               object should be the name of the interface as assigned
               by the local device and should be suitable for use in
               commands entered at the device's `console'.  This
               might be a text name, such as `le0' or a simple port
               number, such as `1', depending on the interface naming
               syntax of the device.  If several entries in the
               ifTable together represent a single interface as named
               by the device, then each will have the same value of
               ifName.  Note that for an agent which responds to SNMP
               queries concerning an interface on some other
               (proxied) device, then the value of ifName for such an
               interface is the proxied device's local name for it.

               If there is no local name, or this object is otherwise
               not applicable, then this object contains a zero-
               length string."
       ::= { ifXEntry 1 }




McCloghrie & Kastenholz     Standards Track                    [Page 39]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   ifInMulticastPkts OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The number of packets, delivered by this sub-layer to
               a higher (sub-)layer, which were addressed to a
               multicast address at this sub-layer.  For a MAC layer
               protocol, this includes both Group and Functional
               addresses.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."
       ::= { ifXEntry 2 }

   ifInBroadcastPkts OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The number of packets, delivered by this sub-layer to
               a higher (sub-)layer, which were addressed to a
               broadcast address at this sub-layer.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."
       ::= { ifXEntry 3 }

   ifOutMulticastPkts OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The total number of packets that higher-level
               protocols requested be transmitted, and which were
               addressed to a multicast address at this sub-layer,
               including those that were discarded or not sent.  For
               a MAC layer protocol, this includes both Group and
               Functional addresses.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."



McCloghrie & Kastenholz     Standards Track                    [Page 40]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


       ::= { ifXEntry 4 }

   ifOutBroadcastPkts OBJECT-TYPE
       SYNTAX      Counter32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The total number of packets that higher-level
               protocols requested be transmitted, and which were
               addressed to a broadcast address at this sub-layer,
               including those that were discarded or not sent.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."
       ::= { ifXEntry 5 }

   --
   -- High Capacity Counter objects.  These objects are all
   -- 64 bit versions of the "basic" ifTable counters.  These
   -- objects all have the same basic semantics as their 32-bit
   -- counterparts, however, their syntax has been extended
   -- to 64 bits.
   --

   ifHCInOctets OBJECT-TYPE
       SYNTAX      Counter64
       MAX-ACCESS  read-only
       STATUS      current

       DESCRIPTION
               "The total number of octets received on the interface,
               including framing characters.  This object is a 64-bit
               version of ifInOctets.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."
       ::= { ifXEntry 6 }










McCloghrie & Kastenholz     Standards Track                    [Page 41]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   ifHCInUcastPkts OBJECT-TYPE
       SYNTAX      Counter64
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The number of packets, delivered by this sub-layer to
               a higher (sub-)layer, which were not addressed to a
               multicast or broadcast address at this sub-layer.
               This object is a 64-bit version of ifInUcastPkts.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."
       ::= { ifXEntry 7 }

   ifHCInMulticastPkts OBJECT-TYPE
       SYNTAX      Counter64
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The number of packets, delivered by this sub-layer to
               a higher (sub-)layer, which were addressed to a
               multicast address at this sub-layer.  For a MAC layer
               protocol, this includes both Group and Functional
               addresses.  This object is a 64-bit version of
               ifInMulticastPkts.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."
       ::= { ifXEntry 8 }


   ifHCInBroadcastPkts OBJECT-TYPE
       SYNTAX      Counter64
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The number of packets, delivered by this sub-layer to
               a higher (sub-)layer, which were addressed to a
               broadcast address at this sub-layer.  This object is a
               64-bit version of ifInBroadcastPkts.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of



McCloghrie & Kastenholz     Standards Track                    [Page 42]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


               ifCounterDiscontinuityTime."
       ::= { ifXEntry 9 }

   ifHCOutOctets OBJECT-TYPE
       SYNTAX      Counter64
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The total number of octets transmitted out of the
               interface, including framing characters.  This object
               is a 64-bit version of ifOutOctets.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."
       ::= { ifXEntry 10 }

   ifHCOutUcastPkts OBJECT-TYPE
       SYNTAX      Counter64
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The total number of packets that higher-level
               protocols requested be transmitted, and which were not
               addressed to a multicast or broadcast address at this
               sub-layer, including those that were discarded or not
               sent.  This object is a 64-bit version of
               ifOutUcastPkts.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."
       ::= { ifXEntry 11 }

   ifHCOutMulticastPkts OBJECT-TYPE
       SYNTAX      Counter64
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The total number of packets that higher-level
               protocols requested be transmitted, and which were
               addressed to a multicast address at this sub-layer,
               including those that were discarded or not sent.  For
               a MAC layer protocol, this includes both Group and
               Functional addresses.  This object is a 64-bit version
               of ifOutMulticastPkts.



McCloghrie & Kastenholz     Standards Track                    [Page 43]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."
       ::= { ifXEntry 12 }

   ifHCOutBroadcastPkts OBJECT-TYPE
       SYNTAX      Counter64
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The total number of packets that higher-level
               protocols requested be transmitted, and which were
               addressed to a broadcast address at this sub-layer,
               including those that were discarded or not sent.  This
               object is a 64-bit version of ifOutBroadcastPkts.

               Discontinuities in the value of this counter can occur
               at re-initialization of the management system, and at
               other times as indicated by the value of
               ifCounterDiscontinuityTime."
       ::= { ifXEntry 13 }

   ifLinkUpDownTrapEnable  OBJECT-TYPE
       SYNTAX      INTEGER { enabled(1), disabled(2) }
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION

               "Indicates whether linkUp/linkDown traps should be
               generated for this interface.

               By default, this object should have the value
               enabled(1) for interfaces which do not operate on
               'top' of any other interface (as defined in the
               ifStackTable), and disabled(2) otherwise."
       ::= { ifXEntry 14 }

   ifHighSpeed OBJECT-TYPE
       SYNTAX      Gauge32
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "An estimate of the interface's current bandwidth in
               units of 1,000,000 bits per second.  If this object
               reports a value of `n' then the speed of the interface
               is somewhere in the range of `n-500,000' to
               `n+499,999'.  For interfaces which do not vary in



McCloghrie & Kastenholz     Standards Track                    [Page 44]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


               bandwidth or for those where no accurate estimation
               can be made, this object should contain the nominal
               bandwidth.  For a sub-layer which has no concept of
               bandwidth, this object should be zero."
       ::= { ifXEntry 15 }

   ifPromiscuousMode  OBJECT-TYPE
       SYNTAX      TruthValue
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
               "This object has a value of false(2) if this interface
               only accepts packets/frames that are addressed to this
               station.  This object has a value of true(1) when the
               station accepts all packets/frames transmitted on the
               media.  The value true(1) is only legal on certain
               types of media.  If legal, setting this object to a
               value of true(1) may require the interface to be reset
               before becoming effective.

               The value of ifPromiscuousMode does not affect the
               reception of broadcast and multicast packets/frames by
               the interface."
       ::= { ifXEntry 16 }

   ifConnectorPresent   OBJECT-TYPE
       SYNTAX      TruthValue
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "This object has the value 'true(1)' if the interface
               sublayer has a physical connector and the value
               'false(2)' otherwise."
       ::= { ifXEntry 17 }

   ifAlias   OBJECT-TYPE
       SYNTAX      DisplayString (SIZE(0..64))
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
               "This object is an 'alias' name for the interface as
               specified by a network manager, and provides a non-
               volatile 'handle' for the interface.

               On the first instantiation of an interface, the value
               of ifAlias associated with that interface is the
               zero-length string.  As and when a value is written
               into an instance of ifAlias through a network



McCloghrie & Kastenholz     Standards Track                    [Page 45]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


               management set operation, then the agent must retain
               the supplied value in the ifAlias instance associated
               with the same interface for as long as that interface
               remains instantiated, including across all re-
               initializations/reboots of the network management
               system, including those which result in a change of
               the interface's ifIndex value.

               An example of the value which a network manager might
               store in this object for a WAN interface is the
               (Telco's) circuit number/identifier of the interface.

               Some agents may support write-access only for
               interfaces having particular values of ifType.  An
               agent which supports write access to this object is
               required to keep the value in non-volatile storage,
               but it may limit the length of new values depending on
               how much storage is already occupied by the current
               values for other interfaces."
       ::= { ifXEntry 18 }

   ifCounterDiscontinuityTime OBJECT-TYPE
       SYNTAX      TimeStamp
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The value of sysUpTime on the most recent occasion at
               which any one or more of this interface's counters
               suffered a discontinuity.  The relevant counters are
               the specific instances associated with this interface
               of any Counter32 or Counter64 object contained in the
               ifTable or ifXTable.  If no such discontinuities have
               occurred since the last re-initialization of the local
               management subsystem, then this object contains a zero
               value."
       ::= { ifXEntry 19 }


   --           The Interface Stack Group
   --
   -- Implementation of this group is mandatory for all systems
   --

   ifStackTable  OBJECT-TYPE
        SYNTAX        SEQUENCE OF IfStackEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION



McCloghrie & Kastenholz     Standards Track                    [Page 46]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


               "The table containing information on the relationships
               between the multiple sub-layers of network interfaces.
               In particular, it contains information on which sub-
               layers run 'on top of' which other sub-layers, where
               each sub-layer corresponds to a conceptual row in the
               ifTable.  For example, when the sub-layer with ifIndex
               value x runs over the sub-layer with ifIndex value y,
               then this table contains:

                 ifStackStatus.x.y=active

               For each ifIndex value, I, which identifies an active
               interface, there are always at least two instantiated
               rows in this table associated with I.  For one of
               these rows, I is the value of ifStackHigherLayer; for
               the other, I is the value of ifStackLowerLayer.  (If I
               is not involved in multiplexing, then these are the
               only two rows associated with I.)

               For example, two rows exist even for an interface
               which has no others stacked on top or below it:

                 ifStackStatus.0.x=active
                 ifStackStatus.x.0=active "
        ::= { ifMIBObjects 2 }


   ifStackEntry  OBJECT-TYPE
        SYNTAX        IfStackEntry
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
               "Information on a particular relationship between two
               sub-layers, specifying that one sub-layer runs on
               'top' of the other sub-layer.  Each sub-layer
               corresponds to a conceptual row in the ifTable."
        INDEX { ifStackHigherLayer, ifStackLowerLayer }
        ::= { ifStackTable 1 }


   IfStackEntry ::=
       SEQUENCE {
           ifStackHigherLayer  Integer32,
           ifStackLowerLayer   Integer32,
           ifStackStatus       RowStatus
        }





McCloghrie & Kastenholz     Standards Track                    [Page 47]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   ifStackHigherLayer  OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
               "The value of ifIndex corresponding to the higher
               sub-layer of the relationship, i.e., the sub-layer
               which runs on 'top' of the sub-layer identified by the
               corresponding instance of ifStackLowerLayer.  If there
               is no higher sub-layer (below the internetwork layer),
               then this object has the value 0."
        ::= { ifStackEntry 1 }


   ifStackLowerLayer  OBJECT-TYPE
        SYNTAX        Integer32
        MAX-ACCESS    not-accessible
        STATUS        current
        DESCRIPTION
               "The value of ifIndex corresponding to the lower sub-
               layer of the relationship, i.e., the sub-layer which
               runs 'below' the sub-layer identified by the
               corresponding instance of ifStackHigherLayer.  If
               there is no lower sub-layer, then this object has the
               value 0."
        ::= { ifStackEntry 2 }


   ifStackStatus  OBJECT-TYPE
       SYNTAX         RowStatus
       MAX-ACCESS     read-create
       STATUS         current
       DESCRIPTION
               "The status of the relationship between two sub-
               layers.

               Changing the value of this object from 'active' to
               'notInService' or 'destroy' will likely have
               consequences up and down the interface stack.  Thus,
               write access to this object is likely to be
               inappropriate for some types of interfaces, and many
               implementations will choose not to support write-
               access for any type of interface."
       ::= { ifStackEntry 3 }

   ifStackLastChange OBJECT-TYPE
       SYNTAX         TimeTicks
       MAX-ACCESS     read-only



McCloghrie & Kastenholz     Standards Track                    [Page 48]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


       STATUS         current
       DESCRIPTION
               "The value of sysUpTime at the time of the last change
               of the (whole) interface stack.  A change of the
               interface stack is defined to be any creation,
               deletion, or change in value of any instance of
               ifStackStatus.  If the interface stack has been
               unchanged since the last re-initialization of the
               local network management subsystem, then this object
               contains a zero value."
       ::= { ifMIBObjects 6 }


   --   Generic Receive Address Table
   --
   -- This group of objects is mandatory for all types of
   -- interfaces which can receive packets/frames addressed to
   -- more than one address.
   --
   -- This table replaces the ifExtnsRcvAddr table.  The main
   -- difference is that this table makes use of the RowStatus
   -- textual convention, while ifExtnsRcvAddr did not.

   ifRcvAddressTable  OBJECT-TYPE
       SYNTAX      SEQUENCE OF IfRcvAddressEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
               "This table contains an entry for each address
               (broadcast, multicast, or uni-cast) for which the
               system will receive packets/frames on a particular
               interface, except as follows:

               - for an interface operating in promiscuous mode,
               entries are only required for those addresses for
               which the system would receive frames were it not
               operating in promiscuous mode.

               - for 802.5 functional addresses, only one entry is
               required, for the address which has the functional
               address bit ANDed with the bit mask of all functional
               addresses for which the interface will accept frames.

               A system is normally able to use any unicast address
               which corresponds to an entry in this table as a
               source address."
       ::= { ifMIBObjects 4 }




McCloghrie & Kastenholz     Standards Track                    [Page 49]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   ifRcvAddressEntry  OBJECT-TYPE
       SYNTAX      IfRcvAddressEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
               "A list of objects identifying an address for which
               the system will accept packets/frames on the
               particular interface identified by the index value
               ifIndex."
       INDEX  { ifIndex, ifRcvAddressAddress }
       ::= { ifRcvAddressTable 1 }

   IfRcvAddressEntry ::=
       SEQUENCE {
           ifRcvAddressAddress   PhysAddress,
           ifRcvAddressStatus    RowStatus,
           ifRcvAddressType      INTEGER
       }

   ifRcvAddressAddress OBJECT-TYPE
       SYNTAX      PhysAddress
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
               "An address for which the system will accept
               packets/frames on this entry's interface."

       ::= { ifRcvAddressEntry 1 }

   ifRcvAddressStatus OBJECT-TYPE
       SYNTAX      RowStatus
       MAX-ACCESS  read-create
       STATUS      current
       DESCRIPTION
               "This object is used to create and delete rows in the
               ifRcvAddressTable."

       ::= { ifRcvAddressEntry 2 }

   ifRcvAddressType OBJECT-TYPE
       SYNTAX      INTEGER {
                       other(1),
                       volatile(2),
                       nonVolatile(3)
                   }

       MAX-ACCESS  read-create
       STATUS      current



McCloghrie & Kastenholz     Standards Track                    [Page 50]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


       DESCRIPTION
               "This object has the value nonVolatile(3) for those
               entries in the table which are valid and will not be
               deleted by the next restart of the managed system.
               Entries having the value volatile(2) are valid and
               exist, but have not been saved, so that will not exist
               after the next restart of the managed system.  Entries
               having the value other(1) are valid and exist but are
               not classified as to whether they will continue to
               exist after the next restart."

       DEFVAL  { volatile }
       ::= { ifRcvAddressEntry 3 }

   -- definition of interface-related traps.

   linkDown NOTIFICATION-TYPE
           OBJECTS { ifIndex, ifAdminStatus, ifOperStatus }
           STATUS  current
           DESCRIPTION
               "A linkDown trap signifies that the SNMPv2 entity,
               acting in an agent role, has detected that the
               ifOperStatus object for one of its communication links
               is about to enter the down state from some other state
               (but not from the notPresent state).  This other state
               is indicated by the included value of ifOperStatus."
       ::= { snmpTraps 3 }

   linkUp NOTIFICATION-TYPE
           OBJECTS { ifIndex, ifAdminStatus, ifOperStatus }
           STATUS  current
           DESCRIPTION
               "A linkDown trap signifies that the SNMPv2 entity,
               acting in an agent role, has detected that the
               ifOperStatus object for one of its communication links
               left the down state and transitioned into some other
               state (but not into the notPresent state).  This other
               state is indicated by the included value of
               ifOperStatus."
       ::= { snmpTraps 4 }

   -- conformance information

   ifConformance OBJECT IDENTIFIER ::= { ifMIB 2 }

   ifGroups      OBJECT IDENTIFIER ::= { ifConformance 1 }
   ifCompliances OBJECT IDENTIFIER ::= { ifConformance 2 }




McCloghrie & Kastenholz     Standards Track                    [Page 51]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   -- compliance statements

   ifCompliance2 MODULE-COMPLIANCE
       STATUS  current
       DESCRIPTION
               "The compliance statement for SNMPv2 entities which
               have network interfaces."

       MODULE  -- this module
           MANDATORY-GROUPS { ifGeneralInformationGroup, ifStackGroup2,
                              ifCounterDiscontinuityGroup }

           GROUP       ifFixedLengthGroup
           DESCRIPTION
               "This group is mandatory for all network interfaces
               which are character-oriented or transmit data in
               fixed-length transmission units."

           GROUP       ifHCFixedLengthGroup
           DESCRIPTION
               "This group is mandatory only for those network
               interfaces which are character-oriented or transmit
               data in fixed-length transmission units, and for which
               the value of the corresponding instance of ifSpeed is
               greater than 20,000,000 bits/second."

           GROUP       ifPacketGroup
           DESCRIPTION
               "This group is mandatory for all network interfaces
               which are packet-oriented."

           GROUP       ifHCPacketGroup
           DESCRIPTION
               "This group is mandatory only for those network
               interfaces which are packet-oriented and for which the
               value of the corresponding instance of ifSpeed is
               greater than 650,000,000 bits/second."

           GROUP       ifRcvAddressGroup
           DESCRIPTION
               "The applicability of this group MUST be defined by
               the media-specific MIBs.  Media-specific MIBs must
               define the exact meaning, use, and semantics of the
               addresses in this group."







McCloghrie & Kastenholz     Standards Track                    [Page 52]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


           OBJECT      ifLinkUpDownTrapEnable
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required."

           OBJECT      ifPromiscuousMode
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required."

           OBJECT      ifStackStatus
           SYNTAX      INTEGER { active(1) } -- subset of RowStatus
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required, and only one of the six
               enumerated values for the RowStatus textual convention
               need be supported, specifically: active(1)."

           OBJECT       ifAdminStatus
           SYNTAX       INTEGER { up(1), down(2) }
           MIN-ACCESS   read-only
           DESCRIPTION
               "Write access is not required, nor is support for the
               value testing(3)."

           OBJECT       ifAlias
           MIN-ACCESS   read-only
           DESCRIPTION
               "Write access is not required."

       ::= { ifCompliances 2 }

   -- units of conformance

   ifGeneralInformationGroup    OBJECT-GROUP
       OBJECTS { ifIndex, ifDescr, ifType, ifSpeed, ifPhysAddress,
                 ifAdminStatus, ifOperStatus, ifLastChange,
                 ifLinkUpDownTrapEnable, ifConnectorPresent,
                 ifHighSpeed, ifName, ifNumber, ifAlias,
                 ifTableLastChange }
       STATUS  current
       DESCRIPTION
               "A collection of objects providing information
               applicable to all network interfaces."
       ::= { ifGroups 10 }

   -- the following five groups are mutually exclusive; at most
   -- one of these groups is implemented for any interface



McCloghrie & Kastenholz     Standards Track                    [Page 53]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   ifFixedLengthGroup    OBJECT-GROUP
       OBJECTS { ifInOctets, ifOutOctets, ifInUnknownProtos,
                 ifInErrors, ifOutErrors }
       STATUS  current
       DESCRIPTION
               "A collection of objects providing information
               specific to non-high speed (non-high speed interfaces
               transmit and receive at speeds less than or equal to
               20,000,000 bits/second) character-oriented or fixed-
               length-transmission network interfaces."
       ::= { ifGroups 2 }

   ifHCFixedLengthGroup    OBJECT-GROUP
       OBJECTS { ifHCInOctets, ifHCOutOctets,
                 ifInOctets, ifOutOctets, ifInUnknownProtos,
                 ifInErrors, ifOutErrors }
       STATUS  current
       DESCRIPTION
               "A collection of objects providing information
               specific to high speed (greater than 20,000,000
               bits/second) character-oriented or fixed-length-
               transmission network interfaces."
       ::= { ifGroups 3 }

   ifPacketGroup    OBJECT-GROUP
       OBJECTS { ifInOctets, ifOutOctets, ifInUnknownProtos,
                 ifInErrors, ifOutErrors,
                 ifMtu, ifInUcastPkts, ifInMulticastPkts,
                 ifInBroadcastPkts, ifInDiscards,
                 ifOutUcastPkts, ifOutMulticastPkts,
                 ifOutBroadcastPkts, ifOutDiscards,
                 ifPromiscuousMode }
       STATUS  current
       DESCRIPTION
               "A collection of objects providing information
               specific to non-high speed (non-high speed interfaces
               transmit and receive at speeds less than or equal to
               20,000,000 bits/second) packet-oriented network
               interfaces."
       ::= { ifGroups 4 }

   ifHCPacketGroup    OBJECT-GROUP
       OBJECTS { ifHCInOctets, ifHCOutOctets,
                 ifInOctets, ifOutOctets, ifInUnknownProtos,
                 ifInErrors, ifOutErrors,
                 ifMtu, ifInUcastPkts, ifInMulticastPkts,
                 ifInBroadcastPkts, ifInDiscards,
                 ifOutUcastPkts, ifOutMulticastPkts,



McCloghrie & Kastenholz     Standards Track                    [Page 54]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


                 ifOutBroadcastPkts, ifOutDiscards,
                 ifPromiscuousMode }
       STATUS  current
       DESCRIPTION
               "A collection of objects providing information
               specific to high speed (greater than 20,000,000
               bits/second but less than or equal to 650,000,000
               bits/second) packet-oriented network interfaces."
       ::= { ifGroups 5 }

   ifVHCPacketGroup    OBJECT-GROUP
       OBJECTS { ifHCInUcastPkts, ifHCInMulticastPkts,
                 ifHCInBroadcastPkts, ifHCOutUcastPkts,
                 ifHCOutMulticastPkts, ifHCOutBroadcastPkts,
                 ifHCInOctets, ifHCOutOctets,
                 ifInOctets, ifOutOctets, ifInUnknownProtos,
                 ifInErrors, ifOutErrors,
                 ifMtu, ifInUcastPkts, ifInMulticastPkts,
                 ifInBroadcastPkts, ifInDiscards,
                 ifOutUcastPkts, ifOutMulticastPkts,
                 ifOutBroadcastPkts, ifOutDiscards,
                 ifPromiscuousMode }
       STATUS  current
       DESCRIPTION
               "A collection of objects providing information
               specific to higher speed (greater than 650,000,000
               bits/second) packet-oriented network interfaces."
       ::= { ifGroups 6 }

   ifRcvAddressGroup    OBJECT-GROUP
       OBJECTS { ifRcvAddressStatus, ifRcvAddressType }
       STATUS  current
       DESCRIPTION
               "A collection of objects providing information on the
               multiple addresses which an interface receives."
       ::= { ifGroups 7 }

   ifStackGroup2    OBJECT-GROUP
       OBJECTS { ifStackStatus, ifStackLastChange }
       STATUS  current
       DESCRIPTION
               "A collection of objects providing information on the
               layering of MIB-II interfaces."
       ::= { ifGroups 11 }

   ifCounterDiscontinuityGroup  OBJECT-GROUP
       OBJECTS { ifCounterDiscontinuityTime }
       STATUS  current



McCloghrie & Kastenholz     Standards Track                    [Page 55]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


       DESCRIPTION
               "A collection of objects providing information
               specific to interface counter discontinuities."
       ::= { ifGroups 13 }

   -- Deprecated Definitions - Objects


   --
   --    The Interface Test Table
   --
   -- This group of objects is optional.  However, a media-specific
   -- MIB may make implementation of this group mandatory.
   --
   -- This table replaces the ifExtnsTestTable
   --

   ifTestTable   OBJECT-TYPE
       SYNTAX      SEQUENCE OF IfTestEntry
       MAX-ACCESS  not-accessible
       STATUS      deprecated
       DESCRIPTION
               "This table contains one entry per interface.  It
               defines objects which allow a network manager to
               instruct an agent to test an interface for various
               faults.  Tests for an interface are defined in the
               media-specific MIB for that interface.  After invoking
               a test, the object ifTestResult can be read to
               determine the outcome.  If an agent can not perform
               the test, ifTestResult is set to so indicate.  The
               object ifTestCode can be used to provide further
               test-specific or interface-specific (or even
               enterprise-specific) information concerning the
               outcome of the test.  Only one test can be in progress
               on each interface at any one time.  If one test is in
               progress when another test is invoked, the second test
               is rejected.  Some agents may reject a test when a
               prior test is active on another interface.

               Before starting a test, a manager-station must first
               obtain 'ownership' of the entry in the ifTestTable for
               the interface to be tested.  This is accomplished with
               the ifTestId and ifTestStatus objects as follows:

            try_again:
                get (ifTestId, ifTestStatus)
                while (ifTestStatus != notInUse)
                    /*



McCloghrie & Kastenholz     Standards Track                    [Page 56]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


                     * Loop while a test is running or some other
                     * manager is configuring a test.
                     */
                    short delay
                    get (ifTestId, ifTestStatus)
                }

                /*
                 * Is not being used right now -- let's compete
                 * to see who gets it.
                 */
                lock_value = ifTestId

                if ( set(ifTestId = lock_value, ifTestStatus = inUse,
                         ifTestOwner = 'my-IP-address') == FAILURE)
                    /*
                     * Another manager got the ifTestEntry -- go
                     * try again
                     */
                    goto try_again;

                /*
                 * I have the lock
                 */
                set up any test parameters.

                /*
                 * This starts the test
                 */
                set(ifTestType = test_to_run);

                wait for test completion by polling ifTestResult

                when test completes, agent sets ifTestResult
                     agent also sets ifTestStatus = 'notInUse'

                retrieve any additional test results, and ifTestId

                if (ifTestId == lock_value+1) results are valid

              A manager station first retrieves the value of the
              appropriate ifTestId and ifTestStatus objects,
              periodically repeating the retrieval if necessary,
              until the value of ifTestStatus is 'notInUse'.  The
              manager station then tries to set the same ifTestId
              object to the value it just retrieved, the same
              ifTestStatus object to 'inUse', and the corresponding
              ifTestOwner object to a value indicating itself.  If



McCloghrie & Kastenholz     Standards Track                    [Page 57]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


              the set operation succeeds then the manager has
              obtained ownership of the ifTestEntry, and the value of
              the ifTestId object is incremented by the agent (per
              the semantics of TestAndIncr).  Failure of the set
              operation indicates that some other manager has
              obtained ownership of the ifTestEntry.

              Once ownership is obtained, any test parameters can be
              setup, and then the test is initiated by setting
              ifTestType.  On completion of the test, the agent sets
              ifTestStatus to 'notInUse'.  Once this occurs, the
              manager can retrieve the results.  In the (rare) event
              that the invocation of tests by two network managers
              were to overlap, then there would be a possibility that
              the first test's results might be overwritten by the
              second test's results prior to the first results being
              read.  This unlikely circumstance can be detected by a
              network manager retrieving ifTestId at the same time as
              retrieving the test results, and ensuring that the
              results are for the desired request.

              If ifTestType is not set within an abnormally long
              period of time after ownership is obtained, the agent
              should time-out the manager, and reset the value of the
              ifTestStatus object back to 'notInUse'.  It is
              suggested that this time-out period be 5 minutes.

              In general, a management station must not retransmit a
              request to invoke a test for which it does not receive
              a response; instead, it properly inspects an agent's
              MIB to determine if the invocation was successful.
              Only if the invocation was unsuccessful, is the
              invocation request retransmitted.

              Some tests may require the interface to be taken off-
              line in order to execute them, or may even require the
              agent to reboot after completion of the test.  In these
              circumstances, communication with the management
              station invoking the test may be lost until after
              completion of the test.  An agent is not required to
              support such tests.  However, if such tests are
              supported, then the agent should make every effort to
              transmit a response to the request which invoked the
              test prior to losing communication.  When the agent is
              restored to normal service, the results of the test are
              properly made available in the appropriate objects.
              Note that this requires that the ifIndex value assigned
              to an interface must be unchanged even if the test



McCloghrie & Kastenholz     Standards Track                    [Page 58]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


              causes a reboot.  An agent must reject any test for
              which it cannot, perhaps due to resource constraints,
              make available at least the minimum amount of
              information after that test completes."
       ::= { ifMIBObjects 3 }

   ifTestEntry OBJECT-TYPE
       SYNTAX       IfTestEntry
       MAX-ACCESS   not-accessible
       STATUS       deprecated
       DESCRIPTION
               "An entry containing objects for invoking tests on an
               interface."
       AUGMENTS  { ifEntry }
       ::= { ifTestTable 1 }

   IfTestEntry ::=
       SEQUENCE {
           ifTestId           TestAndIncr,
           ifTestStatus       INTEGER,
           ifTestType         AutonomousType,
           ifTestResult       INTEGER,
           ifTestCode         OBJECT IDENTIFIER,
           ifTestOwner        OwnerString
       }

   ifTestId         OBJECT-TYPE
       SYNTAX       TestAndIncr
       MAX-ACCESS   read-write
       STATUS       deprecated
       DESCRIPTION
               "This object identifies the current invocation of the
               interface's test."
       ::= { ifTestEntry 1 }

   ifTestStatus     OBJECT-TYPE
       SYNTAX       INTEGER { notInUse(1), inUse(2) }
       MAX-ACCESS   read-write
       STATUS       deprecated
       DESCRIPTION
               "This object indicates whether or not some manager
               currently has the necessary 'ownership' required to
               invoke a test on this interface.  A write to this
               object is only successful when it changes its value
               from 'notInUse(1)' to 'inUse(2)'.  After completion of
               a test, the agent resets the value back to
               'notInUse(1)'."
       ::= { ifTestEntry 2 }



McCloghrie & Kastenholz     Standards Track                    [Page 59]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   ifTestType       OBJECT-TYPE
       SYNTAX       AutonomousType
       MAX-ACCESS   read-write
       STATUS       deprecated
       DESCRIPTION
               "A control variable used to start and stop operator-
               initiated interface tests.  Most OBJECT IDENTIFIER
               values assigned to tests are defined elsewhere, in
               association with specific types of interface.
               However, this document assigns a value for a full-
               duplex loopback test, and defines the special meanings
               of the subject identifier:

                   noTest  OBJECT IDENTIFIER ::= { 0 0 }

               When the value noTest is written to this object, no
               action is taken unless a test is in progress, in which
               case the test is aborted.  Writing any other value to
               this object is only valid when no test is currently in
               progress, in which case the indicated test is
               initiated.

               When read, this object always returns the most recent
               value that ifTestType was set to.  If it has not been
               set since the last initialization of the network
               management subsystem on the agent, a value of noTest
               is returned."
       ::= { ifTestEntry 3 }

   ifTestResult  OBJECT-TYPE
       SYNTAX       INTEGER {
                        none(1),          -- no test yet requested
                        success(2),
                        inProgress(3),
                        notSupported(4),
                        unAbleToRun(5),   -- due to state of system
                        aborted(6),
                        failed(7)
                    }
       MAX-ACCESS   read-only
       STATUS       deprecated
       DESCRIPTION
               "This object contains the result of the most recently
               requested test, or the value none(1) if no tests have
               been requested since the last reset.  Note that this
               facility provides no provision for saving the results
               of one test when starting another, as could be
               required if used by multiple managers concurrently."



McCloghrie & Kastenholz     Standards Track                    [Page 60]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


       ::= { ifTestEntry 4 }

   ifTestCode  OBJECT-TYPE
       SYNTAX       OBJECT IDENTIFIER
       MAX-ACCESS   read-only
       STATUS       deprecated
       DESCRIPTION
               "This object contains a code which contains more
               specific information on the test result, for example
               an error-code after a failed test.  Error codes and
               other values this object may take are specific to the
               type of interface and/or test.  The value may have the
               semantics of either the AutonomousType or
               InstancePointer textual conventions as defined in RFC
               1903.  The identifier:

                   testCodeUnknown  OBJECT IDENTIFIER ::= { 0 0 }

               is defined for use if no additional result code is
               available."
       ::= { ifTestEntry 5 }

   ifTestOwner      OBJECT-TYPE
       SYNTAX       OwnerString
       MAX-ACCESS   read-write
       STATUS       deprecated
       DESCRIPTION
               "The entity which currently has the 'ownership'
               required to invoke a test on this interface."
       ::= { ifTestEntry 6 }

   -- Deprecated Definitions - Groups


   ifGeneralGroup    OBJECT-GROUP
       OBJECTS { ifDescr, ifType, ifSpeed, ifPhysAddress,
                 ifAdminStatus, ifOperStatus, ifLastChange,
                 ifLinkUpDownTrapEnable, ifConnectorPresent,
                 ifHighSpeed, ifName }
       STATUS  deprecated
       DESCRIPTION
               "A collection of objects deprecated in favour of
               ifGeneralInformationGroup."
       ::= { ifGroups 1 }


   ifTestGroup    OBJECT-GROUP
       OBJECTS { ifTestId, ifTestStatus, ifTestType,



McCloghrie & Kastenholz     Standards Track                    [Page 61]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


                 ifTestResult, ifTestCode, ifTestOwner }
       STATUS  deprecated
       DESCRIPTION
               "A collection of objects providing the ability to
               invoke tests on an interface."
       ::= { ifGroups 8 }


   ifStackGroup    OBJECT-GROUP
       OBJECTS { ifStackStatus }
       STATUS  deprecated
       DESCRIPTION
               "The previous collection of objects providing
               information on the layering of MIB-II interfaces."
       ::= { ifGroups 9 }


   ifOldObjectsGroup    OBJECT-GROUP
       OBJECTS { ifInNUcastPkts, ifOutNUcastPkts,
                 ifOutQLen, ifSpecific }
       STATUS  deprecated
       DESCRIPTION
               "The collection of objects deprecated from the
               original MIB-II interfaces group."
       ::= { ifGroups 12 }


   -- Deprecated Definitions - Compliance

   ifCompliance MODULE-COMPLIANCE
       STATUS  deprecated
       DESCRIPTION
               "The previous compliance statement for SNMPv2 entities
               which have network interfaces."

       MODULE  -- this module
           MANDATORY-GROUPS { ifGeneralGroup, ifStackGroup }

           GROUP       ifFixedLengthGroup
           DESCRIPTION
               "This group is mandatory for all network interfaces
               which are character-oriented or transmit data in
               fixed-length transmission units."

           GROUP       ifHCFixedLengthGroup
           DESCRIPTION
               "This group is mandatory only for those network
               interfaces which are character-oriented or transmit



McCloghrie & Kastenholz     Standards Track                    [Page 62]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


               data in fixed-length transmission units, and for which
               the value of the corresponding instance of ifSpeed is
               greater than 20,000,000 bits/second."

           GROUP       ifPacketGroup
           DESCRIPTION
               "This group is mandatory for all network interfaces
               which are packet-oriented."

           GROUP       ifHCPacketGroup
           DESCRIPTION
               "This group is mandatory only for those network
               interfaces which are packet-oriented and for which the
               value of the corresponding instance of ifSpeed is
               greater than 650,000,000 bits/second."

           GROUP       ifTestGroup
           DESCRIPTION
               "This group is optional.  Media-specific MIBs which
               require interface tests are strongly encouraged to use
               this group for invoking tests and reporting results.
               A medium specific MIB which has mandatory tests may
               make implementation of this group mandatory."

           GROUP       ifRcvAddressGroup
           DESCRIPTION
               "The applicability of this group MUST be defined by
               the media-specific MIBs.  Media-specific MIBs must
               define the exact meaning, use, and semantics of the
               addresses in this group."

           OBJECT      ifLinkUpDownTrapEnable
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required."

           OBJECT      ifPromiscuousMode
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required."

           OBJECT      ifStackStatus
           SYNTAX      INTEGER { active(1) } -- subset of RowStatus
           MIN-ACCESS  read-only
           DESCRIPTION
               "Write access is not required, and only one of the six
               enumerated values for the RowStatus textual convention
               need be supported, specifically: active(1)."



McCloghrie & Kastenholz     Standards Track                    [Page 63]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


           OBJECT       ifAdminStatus
           SYNTAX       INTEGER { up(1), down(2) }
           MIN-ACCESS   read-only
           DESCRIPTION
               "Write access is not required, nor is support for the
               value testing(3)."
       ::= { ifCompliances 1 }

   END

7.  Acknowledgements

   This memo has been produced by the IETF's Interfaces MIB working-
   group.

   The original proposal evolved from conversations and discussions with
   many people, including at least the following: Fred Baker, Ted
   Brunner, Chuck Davin, Jeremy Greene, Marshall Rose, Kaj Tesink, and
   Dean Throop.

8.  References

   [1]  Case, J., McCloghrie, K., Rose, M., and
        S. Waldbusser, "Structure of Management Information for
        version 2 of the Simple Network Management Protocol
        (SNMPv2)", RFC 1902, January 1996.

   [2]  Case, J., McCloghrie, K., Rose, M., and
        S. Waldbusser, "Textual Conventions for version 2 of the
        Simple Network Management Protocol (SNMPv2)", RFC 1903,
        January 1996.

   [3]  Case, J., McCloghrie, K., Rose, M., and
        S. Waldbusser, "Protocol Operations for version 2 of the
        Simple Network Management Protocol (SNMPv2)", RFC 1905,
        January 1996.

   [4]  McCloghrie, K., and M. Rose, "Management Information Base for
        Network Management of TCP/IP-based internets - MIB-II", STD
        17, RFC 1213, March 1991.

   [5]  Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple
        Network Management Protocol", STD 15, RFC 1157, May 1990.

   [6]  Postel, J., "Internet Protocol", STD 5, RFC 791, September 1981.

   [7]  McCloghrie, K., "Extensions to the Generic-Interface MIB", RFC
        1229, May 1991.



McCloghrie & Kastenholz     Standards Track                    [Page 64]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


   [8]  ATM Forum Technical Committee, "LAN Emulation Client
        Management: Version 1.0 Specification", af-lane-0044.000, ATM
        Forum, September 1995.

   [9]  Stewart, B., "Definitions of Managed Objects for Character
        Stream Devices using SMIv2", RFC 1658, July 1994.

   [10] Bradner, S., "Key words for use in RFCs to Indicate
        Requirements Levels", RFC 2119, March 1997.

9.  Security Considerations

   This MIB contains both readable objects whose values provide the
   number and status of a device's network interfaces, and write-able
   objects which allow an administrator to control the interfaces and to
   perform tests on the interfaces.  Unauthorized access to the readable
   objects is relatively innocuous.  Unauthorized access to the write-
   able objects could cause a denial of service, or in combination with
   other (e.g., physical) security breaches, could cause unauthorized
   connectivity to a device.

10.  Authors' Addresses

   Keith McCloghrie
   Cisco Systems, Inc.
   170 West Tasman Drive
   San Jose, CA  95134-1706

   Phone: 408-526-5260
   EMail: kzm@cisco.com


   Frank Kastenholz
   FTP Software
   2 High Street
   North Andover, Mass. USA 01845

   Phone: 508-685-4000
   EMail: kasten@ftp.com












McCloghrie & Kastenholz     Standards Track                    [Page 65]


RFC 2233            Interfaces Group MIB using SMIv2       November 1997


11.  Full Copyright Statement

   Copyright (C) The Internet Society (1997).  All Rights Reserved.

   This document and translations of it may be copied and furnished to
   others, and derivative works that comment on or otherwise explain it
   or assist in its implementation may be prepared, copied, published
   and distributed, in whole or in part, without restriction of any
   kind, provided that the above copyright notice and this paragraph are
   included on all such copies and derivative works.  However, this
   document itself may not be modified in any way, such as by removing
   the copyright notice or references to the Internet Society or other
   Internet organizations, except as needed for the purpose of
   developing Internet standards in which case the procedures for
   copyrights defined in the Internet Standards process must be
   followed, or as required to translate it into languages other than
   English.

   The limited permissions granted above are perpetual and will not be
   revoked by the Internet Society or its successors or assigns.

   This document and the information contained herein is provided on an
   "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
   TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
   BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
   HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
   MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
























McCloghrie & Kastenholz     Standards Track                    [Page 66]