RFC 3592, "Definitions of Managed Objects for the Synchronous Optical Network/Synchronous Digital Hierarchy (SONET/SDH) Interface Type", September 2003

Source of RFC: vgmib (int)

Errata ID: 3742
Status: Held for Document Update
Type: Technical
Publication Format(s) : TEXT

Reported By: Anshul Chandra
Date Reported: 2013-10-04
Held for Document Update by: Benoit Claise
Date Held: 2013-10-26

Section 3.5 says:

increase the UAS count by 10 when it
determines that available time has been entered.

It should say:

increase the UAS count by 10 when it
determines that unavailable time has been entered.

Notes:

the word "available" should be changed to "unavailable";