RFC Errata


Errata Search

 
Source of RFC  
Summary Table Full Records

Found 1 record.

Status: Verified (1)

RFC 7839, "Access-Network-Identifier Option in DHCP", June 2016

Source of RFC: dhc (int)

Errata ID: 7016
Status: Verified
Type: Technical
Publication Format(s) : TEXT

Reported By: Alan DeKok
Date Reported: 2022-07-07
Verifier Name: Eric Vyncke
Date Verified: 2022-07-12

Section 4.4.1 says:

   Length
      4

   Operator-Identifier
      The Operator-Identifier is a variable-length Private Enterprise
      Number (PEN) ...

It should say:

   Length
      4

   Operator-Identifier
      The Operator-Identifier is a 32-bit Private Enterprise
      Number (PEN) ...

Notes:

Either the length is 4, and the contents are 32-bits. Or the length is >1, and the length is variable.

My guess is that the intention is to have a fixed length. The variable-length encoding from RFC 6757 is likely not needed here.


*** verifier note ***
See Bernie Volz's reply in https://mailarchive.ietf.org/arch/msg/dhcwg/Y4yaYwaqxS0B2nWw5f4xER2fSMk/