RFC Errata
Found 3 records.
Status: Verified (2)
RFC 7331, "Bidirectional Forwarding Detection (BFD) Management Information Base", August 2014
Source of RFC: bfd (rtg)
Errata ID: 8327
Status: Verified
Type: Technical
Publication Format(s) : TEXT
Reported By: Goutham Jain
Date Reported: 2025-03-01
Verifier Name: John Scudder
Date Verified: 2025-03-18
Section 5 says:
bfdSessUp NOTIFICATION-TYPE OBJECTS { bfdSessDiag, -- low range value bfdSessDiag -- high range value } STATUS current DESCRIPTION "This notification is generated when the bfdSessState object for one or more contiguous entries in bfdSessTable are about to enter the up(4) state from some other state. The included values of bfdSessDiag MUST both be set equal to this new state (i.e., up(4)). The two instances of bfdSessDiag in this notification indicate the range of indexes that are affected. Note that all the indexes of the two ends of the range can be derived from the instance identifiers of these two objects. For the cases where a contiguous range of sessions have transitioned into the up(4) state at roughly the same time, the device SHOULD issue a single notification for each range of contiguous indexes in an effort to minimize the emission of a large number of notifications. If a notification has to be issued for just a single bfdSessEntry, then the instance identifier (and values) of the two bfdSessDiag objects MUST be identical." ::= { bfdNotifications 1 } bfdSessDown NOTIFICATION-TYPE OBJECTS { bfdSessDiag, -- low range value bfdSessDiag -- high range value } STATUS current DESCRIPTION "This notification is generated when the bfdSessState object for one or more contiguous entries in bfdSessTable are about to enter the down(2) or adminDown(1) states from some other state. The included values of bfdSessDiag MUST both be set equal to this new state (i.e., down(2) or adminDown(1)). The two instances of bfdSessDiag in this notification indicate the range of indexes that are affected. Note that all the indexes of the two ends of the range can be derived from the instance identifiers of these two objects. For cases where a contiguous range of sessions have transitioned into the down(2) or adminDown(1) states at roughly the same time, the device SHOULD issue a single notification for each range of contiguous indexes in an effort to minimize the emission of a large number of notifications. If a notification has to be issued for just a single bfdSessEntry, then the instance identifier (and values) of the two bfdSessDiag objects MUST be identical."
It should say:
bfdSessUp NOTIFICATION-TYPE OBJECTS { bfdSessDiag, -- low range value bfdSessDiag -- high range value } STATUS current DESCRIPTION "This notification is generated when the bfdSessState object for one or more contiguous entries in bfdSessTable are about to enter the up(4) state from some other state. The current values of bfdSessDiag MUST be included. The two instances of bfdSessDiag in this notification indicate the range of indexes that are affected. Note that all the indexes of the two ends of the range can be derived from the instance identifiers of these two objects. For the state from some other state. The current values of bfdSessDiag MUST be included. The two instances of the same time, the device SHOULD issue a single notification for each range of contiguous indexes in an effort to minimize the emission of a large number of notifications. If a notification has to be issued for just a single bfdSessEntry, then the instance identifier (and values) of the two bfdSessDiag objects MUST be identical." ::= { bfdNotifications 1 } bfdSessDown NOTIFICATION-TYPE OBJECTS { bfdSessDiag, -- low range value bfdSessDiag -- high range value } STATUS current DESCRIPTION "This notification is generated when the bfdSessState object for one or more contiguous entries in bfdSessTable are about to enter the down(2) or adminDown(1) states from some other state. The current values of bfdSessDiag MUST be included. The two instances of bfdSessDiag in this notification indicate the range of indexes that are affected. Note that all the indexes of the two ends of the range can be derived from the instance identifiers of these two objects. For cases where a contiguous range of sessions have transitioned into the down(2) or adminDown(1) states at roughly the same time, the device SHOULD issue a single notification for each range of contiguous indexes in an effort to minimize the emission of a large number of notifications. If a notification has to be issued for just a single bfdSessEntry, then the instance identifier (and values) of the two bfdSessDiag objects MUST be identical."
Notes:
See discussion at https://mailarchive.ietf.org/arch/msg/rtg-bfd/TGQZeib-j2NAZL2PFPrTykfSLoE/
The changes are
OLD:
state from some other state. The included values of
bfdSessDiag MUST both be set equal to this
new state (i.e., up(4)). The two instances of
NEW:
state from some other state. The current values of
bfdSessDiag MUST be included. The two instances of
and
OLD:
or adminDown(1) states from some other state. The included
values of bfdSessDiag MUST both be set equal to this new
state (i.e., down(2) or adminDown(1)). The two instances
NEW:
or adminDown(1) states from some other state. The current
values of bfdSessDiag MUST be included. The two instances
(The up(4), down(2), and adminDown(1) states are not defined for bfdSessDiag.)
Errata ID: 4214
Status: Verified
Type: Editorial
Publication Format(s) : TEXT
Reported By: Jeffrey Haas
Date Reported: 2014-12-30
Verifier Name: Adrian Farrel
Date Verified: 2015-01-03
Section Various says:
bfdSessionTable, bfdSessionPerfTable
It should say:
bfdSessTable, bfdSessPerfTable
Notes:
Throughout the document, bfdSessionTable and bfdSessionPerfTable are used in various text. The underlying MIB OBJECT-TYPEs are bfdSessTable and bfdSessPerfTable. While these discrepancies occur within the MIB module itself, they do not do so in any component that impacts compilation of the MIB module.
Status: Held for Document Update (1)
RFC 7331, "Bidirectional Forwarding Detection (BFD) Management Information Base", August 2014
Source of RFC: bfd (rtg)
Errata ID: 4441
Status: Held for Document Update
Type: Technical
Publication Format(s) : TEXT
Reported By: Rui Lin
Date Reported: 2015-08-09
Held for Document Update by: Alvaro Retana
Date Held: 2015-08-11
Section 4.5 says:
Given bfdSessInterface, bfdSessSrcAddrType, bfdSessSrcAddr, bfdSessDstAddrType, and bfdSessSrcAddrType, the BFD Session IP Mapping Table maps to an associated BFD session found in the bfdSessionTable.
It should say:
Given bfdSessInterface, bfdSessSrcAddrType, bfdSessSrcAddr, bfdSessDstAddrType, and bfdSessDstAddr, the BFD Session IP Mapping Table maps to an associated BFD session found in the bfdSessionTable.
Notes:
Duplicate bfdSessSrcAddrType but missing bfdSessDstAddr
(Alvaro Retana): the MIB Module itself has the correct description.