RFC Errata


Errata Search

 
Source of RFC  
Summary Table Full Records

Found 2 records.

Status: Verified (1)

RFC 3813, "Multiprotocol Label Switching (MPLS) Label Switching Router (LSR) Management Information Base (MIB)", June 2004

Source of RFC: mpls (rtg)

Errata ID: 228
Status: Verified
Type: Technical
Publication Format(s) : TEXT

Reported By: Michael Kirkham
Date Reported: 2005-02-13
Verifier Name: Adrian Farrel
Date Verified: 2010-08-21

Section mplsLsrModuleReadOnlyCompliance says:

    OBJECT       mplsInSegmentNPop
    SYNTAX       Integer32 (1..1)
    MIN-ACCESS   read-only
    DESCRIPTION "Write access is not required.  This object
                 SHOULD be set to 1 if it is read-only.

It should say:

    OBJECT       mplsInSegmentNPop
    SYNTAX       Integer32 (1)
    MIN-ACCESS   read-only
    DESCRIPTION "Write access is not required.  This object
                 SHOULD be set to 1 if it is read-only.

Notes:

Ref: RFC 2578, section 11.1:

- when a pair of values is specified, the first value
must be less than the second value.

Status: Held for Document Update (1)

RFC 3813, "Multiprotocol Label Switching (MPLS) Label Switching Router (LSR) Management Information Base (MIB)", June 2004

Source of RFC: mpls (rtg)

Errata ID: 229
Status: Held for Document Update
Type: Editorial
Publication Format(s) : TEXT

Reported By: Stefan Winter
Date Reported: 2004-11-17
Held for Document Update by: Adrian Farrel

Description says:

       "For creating, modifying, and deleting this row.
        When a row in this table has a row in the active(1)
        state, no objects in this row except this object
        and the mplsXCStorageType can be modified. "

It should say:

       "For creating, modifying, and deleting this row.
        When a row in this table has a row in the active(1)
        state, no objects in this row except this object, the 
        mplsXCStorageType and the mplsXCAdminStatus can be modified."

Report New Errata



Advanced Search