RFC Errata
Found 1 record.
Status: Verified (1)
RFC 2325, "Definitions of Managed Objects for Drip-Type Heated Beverage Hardware Devices using SMIv2", April 1998
Source of RFC: Legacy
Errata ID: 3993
Status: Verified
Type: Technical
Publication Format(s) : TEXT
Reported By: Jack Lawson
Date Reported: 2014-05-20
Verifier Name: Nevil Brownlee (ISE)
Date Verified: 2014-06-03
Section 4 says:
potType OBJECT-TYPE
SYNTAX INTEGER {
automatic-drip(1),
percolator(2),
french-press(3),
espresso(4),
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The brew type of the coffee pot."
::= { coffee 3 }
It should say:
potType OBJECT-TYPE
SYNTAX INTEGER {
automatic-drip(1),
percolator(2),
french-press(3),
espresso(4),
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The brew type of the coffee pot."
::= { coffee 3 }
Notes:
potName and potCapacity are read-only, as name and capacity will not change after instantiation; type should be as well, as potType will not change over time (reincarnation as a separate pot would constitute a new instance.) potLocation should remain read-write, as a pot may change locations.