RFC Errata
RFC 4379, "Detecting Multi-Protocol Label Switched (MPLS) Data Plane Failures", February 2006
Note: This RFC has been obsoleted by RFC 8029
Note: This RFC has been updated by RFC 5462, RFC 6424, RFC 6425, RFC 6426, RFC 6829, RFC 7506, RFC 7537, RFC 7743
Source of RFC: mpls (rtg)See Also: RFC 4379 w/ inline errata
Errata ID: 108
Status: Verified
Type: Technical
Publication Format(s) : TEXT
Reported By: Alfred Hoenes
Date Reported: 2006-08-12
Verifier Name: Adrian Farrel
Date Verified: 2010-01-02
Section 3 says:
0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Type = 1 (FEC TLV) | Length = 12 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
It should say:
0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ | Type = 1 (FEC TLV) | Length = 32 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
Notes:
According to Section 3.3 of the LDP specification, RFC 3036,
the Lenght element of LDP TLVs measures the size of the Value
element in bytes.
Therefore, 'Length = 12' is wrong, it should be 'Length = 32'.
from pending