Section 12, pg.27 says:

  pwLastChange OBJECT-TYPE
|    SYNTAX        TimeTicks
     MAX-ACCESS    read-only
     STATUS        current
     DESCRIPTION
        "The value of sysUpTime at the time the PW entered
         its current operational state.  If the current state was
         entered prior to the last re-initialization of the local
         network management subsystem, then this object contains a
         zero value."
     ::= { pwEntry 36 }

It should say:

  pwLastChange OBJECT-TYPE
|    SYNTAX        TimeStamp
     MAX-ACCESS    read-only
     STATUS        current
     DESCRIPTION
        "The value of sysUpTime at the time the PW entered
         its current operational state.  If the current state was
         entered prior to the last re-initialization of the local
         network management subsystem, then this object contains a
         zero value."
     ::= { pwEntry 36 }

Notes:

[[ Location is bottom of page 27 ]]

Like any other object intended to keep a snapshot of sysUpTime,
this object must have the corrresponding SYNTAX of TimeStamp
(cf. pwCreateTime, on mid-page 27); a SYNTAX of TimeTicks is
appropriate on;y for 'running clocks' started at a particular
event (like pwUpTime, also on pg. 27, just above pwLastChange).


Although technically correct that the SYNTAX should be TimeStamp, this
is safe because the SYNTAX of TimeStamp is TimeTicks.